Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 21 min ago
Peer-reviewedCC BYBiosensors

Microneedle-Based Optical Biosensors for Point-of-Care Glucose Monitoring in Interstitial Fluid: Recent Advances, Current Challenges, and Future Perspectives.

  1. 1Pharmaceutical Development of Green Innovations Group (PDGIG), Division of Industrial Pharmacy, Faculty of Pharmacy, Silpakorn University, Nakhon Pathom 73000, Thailand.
  2. 2Research and Innovation Center for Advanced Therapy Medicinal Products, Faculty of Pharmacy, Silpakorn University, Nakhon Pathom 73000, Thailand.

Abstract

Microneedle (MN)-based optical biosensors are emerging as minimally invasive platforms for point-of-care testing (POCT) and wearable glucose monitoring by enabling direct access to interstitial fluid (ISF), which closely reflects plasma glucose dynamics. This review summarizes recent advances in MN-based glucose sensing with particular emphasis on optical biosensors. Blood-to-ISF glucose transport, physiological time lag, MN architectures, fabrication strategies, and ISF sampling mechanisms are discussed. Glucose recognition mechanisms are outlined together with optical transduction approaches, including colorimetric, fluorescence, surface-enhanced Raman scattering (SERS), photonic, and plasmonic sensing. Many colorimetric MN platforms currently function as single-use or endpoint POCT systems, whereas reversible fluorescence- and photonic-based sensors provide greater potential for repeated measurements and continuous glucose monitoring. Advanced functional materials, smartphone-assisted readout, and emerging artificial intelligence/machine-learning approaches for signal processing, calibration, and glucose prediction are also examined. Key analytical, mechanical, biocompatibility, and ex vivo/in vivo performance parameters are critically evaluated, together with patents, clinical investigations, and commercialization status. Compared with previous reviews that mainly address ISF sampling, general MN biosensing, glucose monitoring across multiple sensing modalities, or wearable optical sensors separately. This review provides an integrated glucose-specific framework linking ISF physiology, MN-mediated sampling, point-of-care and emerging continuous optical sensing, advanced materials, digital/AI analysis, performance validation, and clinical translation. Finally, current limitations involving biofouling, signal drift, long-term stability, manufacturing scalability, and clinical validation are discussed to highlight future directions toward advanced point-of-care platforms and emerging intelligent, wearable, and continuous glucose-monitoring systems.

Related

  1. A wearable paper-based SGR/MCC microneedle array sensor for continuous glucose monitoring
    Joseph Benjamin Holman, Talifhani Mushiana, C R Yang +5
    Microsystems & NanoengineeringPeer-reviewedCC BYFull text7 citedAnalytical chemistryOpenAlex
  2. Ionic Liquid-Based Biosensors for Disease X: Research Trends, Platform Gaps, and Translational Challenges.
    Murat Kavruk, Esra Menfaatli, Arif Kösemen +2
    BiosensorsPeer-reviewedCC BYFull textAnalytical chemistryEurope PMC
  3. Electrochemical self-powered biosensors for autonomous diagnostics and monitoring: energy sources, recognition interfaces, and translational design rules
    Abdellatif Ait Lahcen, Gymama Slaughter
    Frontiers in Bioengineering and BiotechnologyPeer-reviewedCC BY 4.0Full textAnalytical chemistryPMC
  4. Hybrid Joining Technologies for Composites: Mechanisms, Performance, Challenges, and Perspectives
    Irfan Nazir Wani, Jogendra Kumar, Pulak Gupta
    ChemRxivPreprintLicence not statedGeneral chemistryChemRxiv
  5. Stimulus-responsive molecularly imprinted polymers for bisphenol A and dibutyl phthalate: Analytical trends, challenges, and future perspectives
    Ike Susanti, Aliya Nur Hasanah, Rimadani Pratiwi +1
    Sensors and Actuators ReportsPeer-reviewedCC BYFull textAnalytical chemistryDOAJ
BibTeX
@article{sisavengsouk2026microneedlebased,
  title = {{Microneedle-Based Optical Biosensors for Point-of-Care Glucose Monitoring in Interstitial Fluid: Recent Advances, Current Challenges, and Future Perspectives.}},
  author = {Southamany Sisavengsouk and Boonnada Pamornpathomkul and Tanasait Ngawhirunpat and Praneet Opanasopit and Phuvamin Suriyaamporn},
  journal = {Biosensors},
  year = {2026},
  month = nov,
  doi = {10.3390/bios16110624},
  url = {https://europepmc.org/article/MED/43082519},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Microneedle-Based Optical Biosensors for Point-of-Care Glucose Monitoring in Interstitial Fluid: Recent Advances, Current Challenges, and Future Perspectives.
AU  - Southamany Sisavengsouk
AU  - Boonnada Pamornpathomkul
AU  - Tanasait Ngawhirunpat
AU  - Praneet Opanasopit
AU  - Phuvamin Suriyaamporn
PY  - 2026
DA  - 2026/11/02
JO  - Biosensors
DO  - 10.3390/bios16110624
UR  - https://europepmc.org/article/MED/43082519
AB  - Microneedle (MN)-based optical biosensors are emerging as minimally invasive platforms for point-of-care testing (POCT) and wearable glucose monitoring by enabling direct access to interstitial fluid (ISF), which closely reflects plasma glucose dynamics. This review summarizes recent advances in MN-based glucose sensing with particular emphasis on optical biosensors. Blood-to-ISF glucose transport, physiological time lag, MN architectures, fabrication strategies, and ISF sampling mechanisms are discussed. Glucose recognition mechanisms are outlined together with optical transduction approaches, including colorimetric, fluorescence, surface-enhanced Raman scattering (SERS), photonic, and plasmonic sensing. Many colorimetric MN platforms currently function as single-use or endpoint POCT systems, whereas reversible fluorescence- and photonic-based sensors provide greater potential for repeated measurements and continuous glucose monitoring. Advanced functional materials, smartphone-assisted readout, and emerging artificial intelligence/machine-learning approaches for signal processing, calibration, and glucose prediction are also examined. Key analytical, mechanical, biocompatibility, and ex vivo/in vivo performance parameters are critically evaluated, together with patents, clinical investigations, and commercialization status. Compared with previous reviews that mainly address ISF sampling, general MN biosensing, glucose monitoring across multiple sensing modalities, or wearable optical sensors separately. This review provides an integrated glucose-specific framework linking ISF physiology, MN-mediated sampling, point-of-care and emerging continuous optical sensing, advanced materials, digital/AI analysis, performance validation, and clinical translation. Finally, current limitations involving biofouling, signal drift, long-term stability, manufacturing scalability, and clinical validation are discussed to highlight future directions toward advanced point-of-care platforms and emerging intelligent, wearable, and continuous glucose-monitoring systems.
SN  - 2079-6374
ER  -