Use of Pointwise Encoding Time Reduction with Radial Acquisition Magnetic Resonance Angiography for Coil Embolization
- 1Department of Radiology, Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine, Wonju, South Korea
- 2Department of Nuclear Medicine, Wonju Severance Christian Hospital, Yonsei University Wonju College of Medicine, Wonju, South Korea
Abstract
Introduction: It is imperative to perform imaging evaluation following endovascular coil treatment for cerebral aneurysms. Noninvasive vascular assessment using Magnetic Resonance Angiography (MRA), specifically Time-of-Flight (TOF) MRA, is commonly performed. Thus, this study assessed the diagnostic performance of Pointwise Encoding Time Reduction with Radial Acquisition (PETRA) MRA in patients who underwent simple coil embolization.
Methods: Occlusion status, overall image quality, and treated-site image quality were compared across Digital Subtraction Angiography (DSA), TOF MRA, and PETRA MRA obtained during the same follow-up session after simple coil embolization of intracranial aneurysms.
Results: Overall, 366 patients (median age: 61 ± 13 years) with 373 aneurysms underwent DSA, TOF MRA, and PETRA MRA following simple coil embolization. Occlusion status on PETRA MRA (85 cases, 91.4%) revealed stronger consistency with DSA than with TOF MRA (60 cases, 64.5%). Moreover, PETRA MRA demonstrated higher sensitivity for detecting residual neck and aneurysm (Raymond II and IIIa) compared with TOF MRA (Raymond II: 89% vs. 69%, p < 0.05; Raymond IIIa: 93% vs. 50%, p < 0.05). Notably, no significant differences were observed in overall or treated-site image quality between the techniques (p = 0.9).
Discussion: PETRA MRA provides better visualization of residual flow within the coil mass and exhibits greater agreement with DSA than with TOF MRA. It also serves as an effective follow-up imaging modality, preserving image quality while enhancing diagnostic accuracy.
Conclusion: PETRA MRA offers superior diagnostic performance compared with TOF MRA for follow-up evaluation following simple coil embolization of cerebral aneurysms.
Related
- Pointwise Encoding Time Reduction With Radial Acquisition MRI-Derived Osteochondral Thickness Ratio for Assessing Early Knee Osteoarthritis: A Prospective Case-Control Study.
- Digital subtraction angiography-guided spermatic vein embolization plus sclerosis and microsurgical varicocelectomy in the treatment of varicocele: a comparative study with propensity score matching
- Combined non-contrast enhancement 3D bright-blood and 2D black-blood coronary magnetic resonance angiography for the assessment of coronary artery stenosis
- Low-kV high-pitch one-scan aortic and coronary CT angiography using dual-source photon-counting CT: comparison with separate acquisition strategies.
- Pulmonary Artery CT Angiography on Photon-Counting Detector CT: A Practical One-Stop Acquisition, Reconstruction, and Reporting Protocol.
BibTeX
@article{kim2026pointwise,
title = {{Use of Pointwise Encoding Time Reduction with Radial Acquisition Magnetic Resonance Angiography for Coil Embolization}},
author = {Jin Woo Kim and Hyunjung Kim and Jhii-Hyun Ahn and Jang Yoo and Sung Min Ko},
journal = {Current Medical Imaging},
year = {2026},
month = aug,
doi = {10.2174/0115734056487521260819052008},
url = {https://doi.org/10.2174/0115734056487521260819052008},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Use of Pointwise Encoding Time Reduction with Radial Acquisition Magnetic Resonance Angiography for Coil Embolization
AU - Jin Woo Kim
AU - Hyunjung Kim
AU - Jhii-Hyun Ahn
AU - Jang Yoo
AU - Sung Min Ko
PY - 2026
DA - 2026/08/27
JO - Current Medical Imaging
DO - 10.2174/0115734056487521260819052008
UR - https://doi.org/10.2174/0115734056487521260819052008
AB - Introduction: It is imperative to perform imaging evaluation following endovascular coil treatment for cerebral aneurysms. Noninvasive vascular assessment using Magnetic Resonance Angiography (MRA), specifically Time-of-Flight (TOF) MRA, is commonly performed. Thus, this study assessed the diagnostic performance of Pointwise Encoding Time Reduction with Radial Acquisition (PETRA) MRA in patients who underwent simple coil embolization. Methods: Occlusion status, overall image quality, and treated-site image quality were compared across Digital Subtraction Angiography (DSA), TOF MRA, and PETRA MRA obtained during the same follow-up session after simple coil embolization of intracranial aneurysms. Results: Overall, 366 patients (median age: 61 ± 13 years) with 373 aneurysms underwent DSA, TOF MRA, and PETRA MRA following simple coil embolization. Occlusion status on PETRA MRA (85 cases, 91.4%) revealed stronger consistency with DSA than with TOF MRA (60 cases, 64.5%). Moreover, PETRA MRA demonstrated higher sensitivity for detecting residual neck and aneurysm (Raymond II and IIIa) compared with TOF MRA (Raymond II: 89% vs. 69%, p < 0.05; Raymond IIIa: 93% vs. 50%, p < 0.05). Notably, no significant differences were observed in overall or treated-site image quality between the techniques (p = 0.9). Discussion: PETRA MRA provides better visualization of residual flow within the coil mass and exhibits greater agreement with DSA than with TOF MRA. It also serves as an effective follow-up imaging modality, preserving image quality while enhancing diagnostic accuracy. Conclusion: PETRA MRA offers superior diagnostic performance compared with TOF MRA for follow-up evaluation following simple coil embolization of cerebral aneurysms.
SN - 1573-4056
ER -