Skip to content
DraconiticResearch
Search Sources API
186,625 studies31 sourcesUpdated 20 min ago
Peer-reviewedCC BY-NC-SACentral European journal of urology

Prospective controlled ex vivo observational study on changes in elasticity of ureteral stents following clinical use.

  1. 1Department of Urology, LMU Klinikum, Munich, Germany.

Abstract

Introduction

Ureteral stents significantly impair health-related quality of life. Advances in stent material, particularly in polyurethane compositions, may mitigate adverse effects. This study evaluated ex vivo changes in the elasticity of ureteral stents made from a novel thermoplastic polyurethane composite (HybridPRO Technology by Urotech) compared to a control stent.Material and methods

In this prospective controlled ex vivo observational study, 97 patients undergoing ureteroscopy received one of two types of tethered 7 Fr, 28 cm ureteral stents. Eleven patients underwent bilateral procedures, yielding a total of 108 stents (54 per group). Group 1 received a polyurethane stent with HybridPRO Technology and group 2 received a polyurethane stent without HybridPRO Technology. After removal, stents were measured at the patient's bedside using a hanging apparatus with a predetermined 400 g load. In vitro (room temperature) and ex vivo elongations were recorded, and the net difference was calculated.Results

In vitro measurements showed a median elongation of 4 mm (IQR: 4-4) in group 1 vs 2 mm (IQR: 2-2) in group 2. Ex vivo, group 1 elongated significantly more (median, 12 mm; IQR: 11-13) compared to group 2 (median: 5 mm; IQR: 4-6; p <0.001). The net difference was larger in group 1 (median: 10 mm; IQR, 9-11) compared to group 2 (median: 3 mm; IQR: 2-4; p <0.001).Conclusions

Ureteral stents incorporating HybridPRO Technology demonstrated significantly greater elongation under standardized load after use compared to a control stent. These findings indicate material changes ex vivo; however, the clinical implications regarding comfort or quality of life remain to be determined in future studies.

Related

  1. Incidence and Progression of Acute Kidney Injury Following Head and Neck Surgeries for COVID-19-Associated Mucormycosis: A Prospective Observational Study
    Kalyani M Rapeti, Habib Md R Karim, Chinmaya K Panda +3
    CureusPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Ultrasonographic changes following pyeloplasty in children with ureteropelvic junction obstruction: a prospective observational before-after cohort study
    Farnoush Izadfar, Reza Abbasioun, Ahmad Mohammadipour +5
    Annals of medicine and surgery (2012)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. Longitudinal Changes in Anxiety and Depression Following First Implantable Cardioverter-Defibrillator Implantation: A Prospective Observational Study
    Vincenzo Sgaramella, Antonio Gianluca Robles, Domenico Rosario Riccardo Chieppa +7
    Medicina (Kaunas, Lithuania)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  4. Identification and operative vs. conservative vs. no treatment trial of breastfeeding-impeding lingual frenulum in newborn infants (LINNE): protocol for a randomized controlled trial (RCT) embedded in a prospective observational cohort study in Northern Finland
    Stiina Aitamurto, Venla Lohi, Anu Lehtinen +2
    TrialsPeer-reviewedCC BY-NC-ND 4.0Clinical trials & evidence synthesisCrossref
  5. Laparoscopic urinary tract reconstruction for iatrogenic ureteral injuries: a retrospective observational study from a single high-volume referral center
    Minoru Nakazono, Fumihiko Urabe, Hidetsugu Takahashi +6
    Translational andrology and urologyPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
BibTeX
@article{hoffmann2026prospective,
  title = {{Prospective controlled ex vivo observational study on changes in elasticity of ureteral stents following clinical use.}},
  author = {Marina Hoffmann and Benedikt Ebner and Nikolaos Pyrgidis and Iulia Blajan and Troya Georgieva and Marc Kidess and Moritz Happe and Yannic Volz and Lennert Eismann and Maria Apfelbeck and Christian G Stief and Michael Chaloupka},
  journal = {Central European journal of urology},
  year = {2026},
  month = jun,
  doi = {10.5173/ceju.2025.0216},
  url = {https://europepmc.org/article/MED/42904079},
  note = {CC BY-NC-SA},
}
RIS
TY  - JOUR
TI  - Prospective controlled ex vivo observational study on changes in elasticity of ureteral stents following clinical use.
AU  - Marina Hoffmann
AU  - Benedikt Ebner
AU  - Nikolaos Pyrgidis
AU  - Iulia Blajan
AU  - Troya Georgieva
AU  - Marc Kidess
AU  - Moritz Happe
AU  - Yannic Volz
AU  - Lennert Eismann
AU  - Maria Apfelbeck
AU  - Christian G Stief
AU  - Michael Chaloupka
PY  - 2026
DA  - 2026/06/12
JO  - Central European journal of urology
DO  - 10.5173/ceju.2025.0216
UR  - https://europepmc.org/article/MED/42904079
AB  - Introduction  Ureteral stents significantly impair health-related quality of life. Advances in stent material, particularly in polyurethane compositions, may mitigate adverse effects. This study evaluated ex vivo changes in the elasticity of ureteral stents made from a novel thermoplastic polyurethane composite (HybridPRO Technology by Urotech) compared to a control stent.Material and methods  In this prospective controlled ex vivo observational study, 97 patients undergoing ureteroscopy received one of two types of tethered 7 Fr, 28 cm ureteral stents. Eleven patients underwent bilateral procedures, yielding a total of 108 stents (54 per group). Group 1 received a polyurethane stent with HybridPRO Technology and group 2 received a polyurethane stent without HybridPRO Technology. After removal, stents were measured at the patient's bedside using a hanging apparatus with a predetermined 400 g load. In vitro (room temperature) and ex vivo elongations were recorded, and the net difference was calculated.Results  In vitro measurements showed a median elongation of 4 mm (IQR: 4-4) in group 1 vs 2 mm (IQR: 2-2) in group 2. Ex vivo, group 1 elongated significantly more (median, 12 mm; IQR: 11-13) compared to group 2 (median: 5 mm; IQR: 4-6; p <0.001). The net difference was larger in group 1 (median: 10 mm; IQR, 9-11) compared to group 2 (median: 3 mm; IQR: 2-4; p <0.001).Conclusions  Ureteral stents incorporating HybridPRO Technology demonstrated significantly greater elongation under standardized load after use compared to a control stent. These findings indicate material changes ex vivo; however, the clinical implications regarding comfort or quality of life remain to be determined in future studies.
SN  - 2080-4806
SN  - 2080-4873
ER  -