Reliability and diagnostic performance of radiologic indices of the proximal humerus in evaluating bone mineral density: a retrospective study
- 1Department of Orthopedics, Peking University Third Hospital, No. 49 North Garden Road, Haidian District, Beijing, 100191 China
- 2Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, 100191 China
- 3School of Statistics, Beijing Normal University, Beijing, 100875 China
Abstract
Background: Proximal humerus fractures (PHFs) are the third most common osteoporotic fractures. Assessment of bone mineral density (BMD) is clinically relevant in patients with PHFs. Several studies have proposed the use of radiologic indices, including the average cortical bone thickness (CBTA), gauge cortical bone thickness, medial cortical ratio, and deltoid tuberosity index (DTI), to assess local BMD in patients with PHFs. In this study, we aimed to assess the reliability of these radiologic indices and determine their diagnostic performance for identifying DXA-defined osteoporosis.
Methods: We retrospectively included 145 individuals who underwent anteroposterior shoulder radiography and dual-energy X-ray absorptiometry (DXA) of the hip and lumbar spine in our hospital between January 2021 and June 2023. Two independent researchers measured the radiologic indices using the shoulder X-ray. The DXA was used to assess BMD.
Results: The intra- and inter-observer reliabilities of the four radiologic indices were good to excellent (ICC = 0.806–0.963). The CBTA demonstrated moderate associations with DXA-derived BMD parameters (r = 0.439–0.517, P < 0.001), DTI also exhibited weak to moderate associations across the examined anatomical sites (r = 0.380–0.500, P < 0.001). Receiver operating characteristic curve analysis demonstrated that the areas under the curve of CBTA and DTI for identifying DXA-defined osteoporosis were 0.844 and 0.842, with optimal cut-off values of 5.71 and 1.38, respectively.
Conclusion: CBTA and DTI showed good measurement reliability and moderate associations with DXA-derived BMD parameters. They may provide supplementary radiologic information on low BMD risk from routine shoulder radiographs and may help identify patients who warrant further DXA evaluation.
Clinical trial number: Not applicable.
Related
- Bone Marrow Dominant Erdheim-Chester Disease Lacking Characteristic Radiologic Findings: A Diagnostic Pitfall.
- Pulmonary Sarcoidosis Mimicking Multifocal Adenocarcinoma: An Atypical Radiologic and Diagnostic Dilemma
- CT-Referenced Diagnostic Performance and Complementary Error Patterns of Artificial Intelligence Versus a Single Emergency Physician in Chest Radiograph Interpretation: A Retrospective Paired Diagnostic Accuracy Study
- Diagnostic Performance of Serum Inflammatory Biomarkers in the Preoperative Differentiation of Uterine Myoma, Adenomyosis and Malignant Uterine Tumors: A Retrospective Study
- Diagnostic Performance of Urinary Keratin 17 Immunocytochemistry (URO17®) During Hematuria Evaluation: A Retrospective Study
BibTeX
@article{yang2026reliability,
title = {{Reliability and diagnostic performance of radiologic indices of the proximal humerus in evaluating bone mineral density: a retrospective study}},
author = {Yiyuan Yang and Zhuo Chen and Kaifeng Ye and Yanling Zhang and Guohong Du and Yun Tian},
journal = {BMC Medical Imaging},
year = {2026},
month = aug,
doi = {10.1186/s12880-026-02661-0},
url = {https://doi.org/10.1186/s12880-026-02661-0},
note = {CC BY-NC-ND 4.0},
}
RIS
TY - JOUR
TI - Reliability and diagnostic performance of radiologic indices of the proximal humerus in evaluating bone mineral density: a retrospective study
AU - Yiyuan Yang
AU - Zhuo Chen
AU - Kaifeng Ye
AU - Yanling Zhang
AU - Guohong Du
AU - Yun Tian
PY - 2026
DA - 2026/08/10
JO - BMC Medical Imaging
DO - 10.1186/s12880-026-02661-0
UR - https://doi.org/10.1186/s12880-026-02661-0
AB - Background: Proximal humerus fractures (PHFs) are the third most common osteoporotic fractures. Assessment of bone mineral density (BMD) is clinically relevant in patients with PHFs. Several studies have proposed the use of radiologic indices, including the average cortical bone thickness (CBTA), gauge cortical bone thickness, medial cortical ratio, and deltoid tuberosity index (DTI), to assess local BMD in patients with PHFs. In this study, we aimed to assess the reliability of these radiologic indices and determine their diagnostic performance for identifying DXA-defined osteoporosis. Methods: We retrospectively included 145 individuals who underwent anteroposterior shoulder radiography and dual-energy X-ray absorptiometry (DXA) of the hip and lumbar spine in our hospital between January 2021 and June 2023. Two independent researchers measured the radiologic indices using the shoulder X-ray. The DXA was used to assess BMD. Results: The intra- and inter-observer reliabilities of the four radiologic indices were good to excellent (ICC = 0.806–0.963). The CBTA demonstrated moderate associations with DXA-derived BMD parameters (r = 0.439–0.517, P < 0.001), DTI also exhibited weak to moderate associations across the examined anatomical sites (r = 0.380–0.500, P < 0.001). Receiver operating characteristic curve analysis demonstrated that the areas under the curve of CBTA and DTI for identifying DXA-defined osteoporosis were 0.844 and 0.842, with optimal cut-off values of 5.71 and 1.38, respectively. Conclusion: CBTA and DTI showed good measurement reliability and moderate associations with DXA-derived BMD parameters. They may provide supplementary radiologic information on low BMD risk from routine shoulder radiographs and may help identify patients who warrant further DXA evaluation. Clinical trial number: Not applicable.
SN - 1471-2342
ER -