Skip to content
DraconiticResearch
Search Sources API
203,203 studies31 sourcesUpdated 32 min ago
Peer-reviewedCC BYPLOS One

Artificial intelligence-based surrogate modeling of hemodynamic indicators in abdominal aortic aneurysms using computational fluid dynamics

4 affiliations
  1. 1Department of Biomedical Engineering, Graduate School, Pusan National University, Busan, Republic of Korea.
  2. 2Department of Thoracic and Cardiovascular Surgery, Pusan National University School of Medicine, Biomedical Research Institute, Pusan National University Hospital, Busan, Republic of Korea.
  3. 3Department of Biomedical Engineering, School of Medicine, Pusan National University, Busan, Republic of Korea.
  4. 4In Silico Medicine Lab, Biomedical Research Institute, Pusan National University Hospital, Busan, Republic of Korea.

Abstract

Abdominal aortic aneurysm (AAA) is a progressive dilatative disease of the abdominal aorta with high rupture-related mortality, emphasizing the need for early risk assessment. Conventional anatomical indicators, such as maximum diameter, are insufficient to characterize rupture risk, motivating the incorporation of hemodynamic parameters. Image-based CFD enables the estimation of these parameters but remains clinically limited by high computational cost and long processing times. To overcome these limitations, deep learning–based surrogate models such as MultiViewUNet have recently been proposed, though previous studies were constrained by relatively low spatial resolution and limited coverage of hemodynamic parameters. In this study, we propose MH-UNet, a multi-view, high-resolution surrogate modeling framework that extends the original MultiViewUNet to a higher input resolution and additional hemodynamic parameters. MH-UNet converts three-dimensional AAA geometries into two-dimensional images from multiple viewing angles and predicts TAWSS, OSI, RRT, and ECAP using data from 101 patients. Both single-inference and dual-inference strategies were implemented and compared. Single-inference consistently outperformed dual-inference across all parameters; the cascaded dual-inference scheme amplified errors through the nonlinear OSI and RRT formulations, resulting in negative R² values for OSI, RRT, and ECAP. Among the single-inference predictions, TAWSS was predicted most reliably (R² = 0.803), whereas OSI was the most challenging to predict. Agreement between single-inference predictions and CFD-derived results demonstrates the potential of MH-UNet as a rapid surrogate tool for estimating WSS-derived hemodynamic indices in AAA under fixed boundary conditions.

Related

  1. Hemodynamic-Structural Multi-Fidelity Assessment of Endovascular Flow Diversion Strategies for Cerebral Aneurysm Treatment: An Integrated Computational and Experimental Framework
    D. Roy, F. S. Antara, S. A. Moshrur +4
    bioRxivPreprintAll rights reservedFull textNeurosciencebioRxiv
  2. Société de Biomécanique senior investigator award 2024—Hemodynamic performance of a bicuspid venous valve: A computational study
    Barthelemy Thibaud, Simon Mendez, Franck Nicoud
    Journal of BiomechanicsPeer-reviewedCC BY 4.0Full textGeneral biologyCardiovascular medicineHAL
  3. Surrogate modeling based on computational fluid dynamics for predicting the capsizing moment in a coupled shiplift system
    Tong Tang, Jianbao Yang, Zikang Hu +3
    PLOS OnePeer-reviewedCC BY 4.0Full textBioinformatics & computational biologyCell biologyPLOS
  4. Food-web reorganization in an artificial reef revealed by flow-based indicators
    Zhipeng Zhang, Jingjing Song, Mingqi Wang +6
    Ecological IndicatorsPeer-reviewedCC BYFull textEcologyDOAJ
  5. Artificial observers and real individual differences: A roadmap for a computational psychometrics of vision
    David Henry Peterzell
    PsyArXivPreprintCC BY 4.0Full textNeuroscienceOSF
BibTeX
@article{suh2026artificial,
  title = {{Artificial intelligence-based surrogate modeling of hemodynamic indicators in abdominal aortic aneurysms using computational fluid dynamics}},
  author = {MyeungHye Suh and Up Huh and Chiseung Lee},
  journal = {PLOS One},
  year = {2026},
  month = oct,
  doi = {10.1371/journal.pone.0348911},
  url = {https://doi.org/10.1371/journal.pone.0348911},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Artificial intelligence-based surrogate modeling of hemodynamic indicators in abdominal aortic aneurysms using computational fluid dynamics
AU  - MyeungHye Suh
AU  - Up Huh
AU  - Chiseung Lee
PY  - 2026
DA  - 2026/10/28
JO  - PLOS One
DO  - 10.1371/journal.pone.0348911
UR  - https://doi.org/10.1371/journal.pone.0348911
AB  - Abdominal aortic aneurysm (AAA) is a progressive dilatative disease of the abdominal aorta with high rupture-related mortality, emphasizing the need for early risk assessment. Conventional anatomical indicators, such as maximum diameter, are insufficient to characterize rupture risk, motivating the incorporation of hemodynamic parameters. Image-based CFD enables the estimation of these parameters but remains clinically limited by high computational cost and long processing times. To overcome these limitations, deep learning–based surrogate models such as MultiViewUNet have recently been proposed, though previous studies were constrained by relatively low spatial resolution and limited coverage of hemodynamic parameters. In this study, we propose MH-UNet, a multi-view, high-resolution surrogate modeling framework that extends the original MultiViewUNet to a higher input resolution and additional hemodynamic parameters. MH-UNet converts three-dimensional AAA geometries into two-dimensional images from multiple viewing angles and predicts TAWSS, OSI, RRT, and ECAP using data from 101 patients. Both single-inference and dual-inference strategies were implemented and compared. Single-inference consistently outperformed dual-inference across all parameters; the cascaded dual-inference scheme amplified errors through the nonlinear OSI and RRT formulations, resulting in negative R² values for OSI, RRT, and ECAP. Among the single-inference predictions, TAWSS was predicted most reliably (R² = 0.803), whereas OSI was the most challenging to predict. Agreement between single-inference predictions and CFD-derived results demonstrates the potential of MH-UNet as a rapid surrogate tool for estimating WSS-derived hemodynamic indices in AAA under fixed boundary conditions.
SN  - 1932-6203
ER  -