Physical realizability classification of incomplete Mueller matrices: toward real-time polarimetric imaging
11 affiliations
- 1LPICM, CNRS, Ecole polytechnique, IP Paris, 91120, Palaiseau, France.
- 2[email protected].
- 3MOE Key Laboratory of Optoelectronic Imaging Technology and System, Beijing Institute of Technology, Beijing 100081, China.
- 4Graduate School at Shenzhen Tsinghua University, Institute of Optical Imaging and Sensing, Shenzhen Key Laboratory for Minimal Invasive Medical Technologies, Shenzhen, China.
- 5Department of Computer Science, ETH Zürich, 8092 Zürich, Switzerland.
- 6Support Centre for Advanced Neuroimaging, Institute of Diagnostic and Interventional Neuroradiology, Inselspital, Bern University Hospital, University of Bern, 3010 Bern, Switzerland.
- 7Department of Neurosurgery, Inselspital, Bern University Hospital, University of Bern, 3010 Bern, Switzerland.
- 8Department of Digital Medicine, University of Bern, 3008 Bern, Switzerland.
- 9Institute of Tissue Medicine and Pathology, University of Bern, 3008 Bern, Switzerland.
- 10Department of Biomedical Engineering, Florida International University, Miami, FL 33174, USA.
- 11[email protected].
Abstract
Translating wide-field imaging Mueller polarimetry to clinical settings requires video-rate data acquisition, achievable with polarization-sensitive division-of-focal-plane cameras. Such sensors measure only the first three rows of a sample's Mueller matrix , yielding a partial 3 × 4 Mueller matrix. Physical realizability testing of Mueller matrix is a mandatory post-processing step, which analytical implementation requires the knowledge of complete 4 × 4 Mueller matrix elements. No closed-form physical realizability test exists for partial Mueller matrices. We present a supervised machine learning framework that tests physical realizability directly on partial Mueller matrices, without the missing fourth row. Three different classifiers - XGBoost, CatBoost, and Multi-Layer Perceptron - were trained and evaluated on experimental Mueller matrix images of brain, skin and cervical tissue and also on polarized Monte Carlo simulated Mueller matrix images of optical phantoms. On independent held-out complete MM images excluded from all stages of model development, the classifiers achieve mean image-level F ₁ scores of 0.973-0.975 across the evaluated partial-MM inputs. We further show that reducing the input to the 3 × 3 top-left sub-matrix shows comparative performance, with all three classifiers generalizing comparably and the Multi-Layer Perceptron classifier offering the fastest inference.
Related
- A Complete Classification of Complex Hadamard Matrices of Order Six
- Microscopic Realizability of Non-unique Bubble Hydrodynamics
- Underwater optical signal detection in degraded environment with polarimetric event camera
- Polarimetric 3D Reconstruction of Colored Targets Based on Narrowband Multispectral Dispersion Constraints and Chromaticity-Based Desaturation
- Realizability and tunability of synchronized optical soliton collision patterns
BibTeX
@article{chae2026physical,
title = {{Physical realizability classification of incomplete Mueller matrices: toward real-time polarimetric imaging}},
author = {Sooyong Chae and Meishu Wang and Theotim Lucas and Tongyu Huang and Gianmarco Albano and Omar Rodriguez-Nunez and Angelo Pierangelo and Elea Gros and Theoni Maragkou and Richard McKinley and Philippe Schucht and Tatiana Novikova},
journal = {Biomedical optics express},
year = {2026},
month = oct,
doi = {10.1364/boe.608210},
url = {https://europepmc.org/article/PMC/PMC13795929},
note = {CC BY},
}
RIS
TY - JOUR
TI - Physical realizability classification of incomplete Mueller matrices: toward real-time polarimetric imaging
AU - Sooyong Chae
AU - Meishu Wang
AU - Theotim Lucas
AU - Tongyu Huang
AU - Gianmarco Albano
AU - Omar Rodriguez-Nunez
AU - Angelo Pierangelo
AU - Elea Gros
AU - Theoni Maragkou
AU - Richard McKinley
AU - Philippe Schucht
AU - Tatiana Novikova
PY - 2026
DA - 2026/10/14
JO - Biomedical optics express
DO - 10.1364/boe.608210
UR - https://europepmc.org/article/PMC/PMC13795929
AB - Translating wide-field imaging Mueller polarimetry to clinical settings requires video-rate data acquisition, achievable with polarization-sensitive division-of-focal-plane cameras. Such sensors measure only the first three rows of a sample's Mueller matrix , yielding a partial 3 × 4 Mueller matrix. Physical realizability testing of Mueller matrix is a mandatory post-processing step, which analytical implementation requires the knowledge of complete 4 × 4 Mueller matrix elements. No closed-form physical realizability test exists for partial Mueller matrices. We present a supervised machine learning framework that tests physical realizability directly on partial Mueller matrices, without the missing fourth row. Three different classifiers - XGBoost, CatBoost, and Multi-Layer Perceptron - were trained and evaluated on experimental Mueller matrix images of brain, skin and cervical tissue and also on polarized Monte Carlo simulated Mueller matrix images of optical phantoms. On independent held-out complete MM images excluded from all stages of model development, the classifiers achieve mean image-level F ₁ scores of 0.973-0.975 across the evaluated partial-MM inputs. We further show that reducing the input to the 3 × 3 top-left sub-matrix shows comparative performance, with all three classifiers generalizing comparably and the Multi-Layer Perceptron classifier offering the fastest inference.
SN - 2156-7085
ER -