Radiomic Profiling of Tumor Heterogeneity Predicts Treatment Response in High-Risk Hodgkin Lymphoma: Results from the Phase III AHOD0831 Trial
6 affiliations
- 1Department of Radiation Oncology, The Ohio State University, Columbus, OH 43210, USA
- 2Department of Biomedical Engineering, University of Miami, Coral Gables, FL 33146, USA
- 3Department of Radiation Oncology, Affiliated Hospital of Jiangnan University, Wuxi 214122, China
- 4Division of Nuclear Medicine, Department of Radiology, University of Miami, Miami, FL 33136, USA
- 5Division of Hematology, Department of Medicine, University of Miami, Miami, FL 33136, USA
- 6Department of Radiation Oncology, University of Miami School of Medicine, Miami, FL 33136, USA
Abstract
Background/Objectives: To determine whether baseline 18F-FDG PET radiomics improves prediction of treatment response in pediatric and adolescent patients with high-risk Hodgkin lymphoma relative to conventional PET-derived biomarkers. Methods: Baseline FDG-PET/CT data from 115 patients enrolled in the multicenter AHOD0831 trial were analyzed. Total metabolic tumor volume (TMTV) and total lesion glycolysis (TLG) were calculated from aggregate volume of all lesions. Fifty-nine second-order textural radiomic features were extracted using three fixed SUV discretization bin widths (0.1, 0.25, and 0.5 SUV). Features were selected using univariable testing, correlation-based redundancy reduction, and repeated bootstrapped subsequent least absolute shrinkage and selection operator (LASSO) regression. Logistic-regression models based on selected radiomic features, radiomic features plus TMTV, and conventional PET biomarkers were evaluated using repeated five-fold cross-validation, receiver-operating-characteristic analysis, and decision-curve analysis. Results: Of 115 patients, 54 (47.0%) achieved complete response, while 61 (53.0%) had partial response or stable disease. A core group of heterogeneity-related radiomic features—including gray-level co-occurrence matrix-based informational measures of correlation, gray-level dependence matrix-based gray-level non-uniformity, and neighboring gray tone difference matrix-based coarseness and strength—was retained across discretization schemes. Repeated LASSO resampling identified a limited subset of stable predictors. Across all datasets, radiomics-only models and hybrid models combining radiomic features with TMTV consistently outperformed conventional models based on TMTV and TMTV plus TLG. Exploratory decision-curve analysis suggested greater estimated net benefit for the best-performing radiomics model than for TMTV alone within a potentially clinically relevant threshold-probability range. Conclusions: Baseline FDG-PET radiomics captures intratumoral metabolic heterogeneity and may improve treatment-response prediction in high-risk Hodgkin lymphoma beyond conventional PET-derived biomarkers. These findings warrant independent external validation to determine whether baseline radiomics can improve risk stratification and inform future response-adapted treatment strategies.
Related
- Multiplexed FRET-FLIM Profiling of Immune Checkpoint Interactions Predicts Response to Atezolizumab in Urothelial Carcinoma
- Spatially Resolved Functional Heterogeneity of Tertiary Lymphoid Structures Combined with Basal-Squamous Epithelial States Predicts Prognosis and Immunotherapy Response in Upper Tract Urothelial Carcinoma
- EP05.31 Radiomics-based machine learning of pre-treatment MRI predicts relapse timing in primary CNS lymphoma after complete response to induction therapy
- EP03.20 Radiomic profiling of the peritumoral microenvironment reveals imaging biomarkers of glioma infiltration linked to Hsp70 expression
- P01.03.A Modeling glioblastoma heterogeneity and treatment response using advanced 3D in vitro models
BibTeX
@article{ji2026radiomic,
title = {{Radiomic Profiling of Tumor Heterogeneity Predicts Treatment Response in High-Risk Hodgkin Lymphoma: Results from the Phase III AHOD0831 Trial}},
author = {Xuemei Ji and Parker Anderson and Jianfeng Huang and Russ Kuker and Juan Pablo Alderuccio and Nesrin Dogan and Fei Yang},
journal = {Cancers},
year = {2026},
month = nov,
doi = {10.3390/cancers18223715},
url = {https://www.mdpi.com/2072-6694/18/22/3715},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Radiomic Profiling of Tumor Heterogeneity Predicts Treatment Response in High-Risk Hodgkin Lymphoma: Results from the Phase III AHOD0831 Trial
AU - Xuemei Ji
AU - Parker Anderson
AU - Jianfeng Huang
AU - Russ Kuker
AU - Juan Pablo Alderuccio
AU - Nesrin Dogan
AU - Fei Yang
PY - 2026
DA - 2026/11/01
JO - Cancers
DO - 10.3390/cancers18223715
UR - https://www.mdpi.com/2072-6694/18/22/3715
AB - Background/Objectives: To determine whether baseline 18F-FDG PET radiomics improves prediction of treatment response in pediatric and adolescent patients with high-risk Hodgkin lymphoma relative to conventional PET-derived biomarkers. Methods: Baseline FDG-PET/CT data from 115 patients enrolled in the multicenter AHOD0831 trial were analyzed. Total metabolic tumor volume (TMTV) and total lesion glycolysis (TLG) were calculated from aggregate volume of all lesions. Fifty-nine second-order textural radiomic features were extracted using three fixed SUV discretization bin widths (0.1, 0.25, and 0.5 SUV). Features were selected using univariable testing, correlation-based redundancy reduction, and repeated bootstrapped subsequent least absolute shrinkage and selection operator (LASSO) regression. Logistic-regression models based on selected radiomic features, radiomic features plus TMTV, and conventional PET biomarkers were evaluated using repeated five-fold cross-validation, receiver-operating-characteristic analysis, and decision-curve analysis. Results: Of 115 patients, 54 (47.0%) achieved complete response, while 61 (53.0%) had partial response or stable disease. A core group of heterogeneity-related radiomic features—including gray-level co-occurrence matrix-based informational measures of correlation, gray-level dependence matrix-based gray-level non-uniformity, and neighboring gray tone difference matrix-based coarseness and strength—was retained across discretization schemes. Repeated LASSO resampling identified a limited subset of stable predictors. Across all datasets, radiomics-only models and hybrid models combining radiomic features with TMTV consistently outperformed conventional models based on TMTV and TMTV plus TLG. Exploratory decision-curve analysis suggested greater estimated net benefit for the best-performing radiomics model than for TMTV alone within a potentially clinically relevant threshold-probability range. Conclusions: Baseline FDG-PET radiomics captures intratumoral metabolic heterogeneity and may improve treatment-response prediction in high-risk Hodgkin lymphoma beyond conventional PET-derived biomarkers. These findings warrant independent external validation to determine whether baseline radiomics can improve risk stratification and inform future response-adapted treatment strategies.
SN - 2072-6694
ER -