Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 53 min ago
Peer-reviewedCC BY 4.0Frontiers in Cardiovascular Medicine

Optimized dual-energy CT protocol for inferior vena cava CT angiography using 60 keV virtual monoenergetic imaging and 60% ASIR-V

3 more authors
5 affiliations
  1. 1Department of Radiology, Suining Central Hospital
  2. 2Department of Radiology, Affiliated Hospital of North Sichuan Medical College
  3. 3Department of Radiology, Affiliated Hospital of Southwest Medical University
  4. 4Department of Radiology and Imaging, Institute of Rehabilitation and Development of Brain Function, The Second Clinical Medical College of North Sichuan Medical College Nanchong Central Hospital
  5. 5Sichuan Key Laboratory of Medical Imaging and Department of Radiology, Affiliated Hospital of North Sichuan Medical College

Abstract

Objective: To investigate the effects of a dual-energy CT (DECT) protocol combining virtual monoenergetic imaging (VMI) with adaptive statistical iterative reconstruction-V (ASIR-V) on image quality and radiation dose for inferior vena cava (IVC) CT angiography (CTA), and to compare the optimized protocol with a conventional 120 kVp protocol.

Methods: 120 consecutive patients undergoing IVC-CTA were enrolled and allocated sequentially to two groups ( n = 60 each). Group A underwent conventional 120 kVp scanning with 400 mgI/mL contrast medium at 1.5 mL/kg and 50% ASIR-V reconstruction. Group B underwent DECT (rapid 80/140 kVp switching) with 320 mgI/mL contrast medium at 1.2 mL/kg. In Group B, seven VMI datasets from 40 to 70 keV in 5 keV increments were first reconstructed with 50% ASIR-V. At 60 keV, images were reconstructed with filtered back projection (FBP; 0% ASIR-V) and ASIR-V levels from 20% to 100% in 20% increments. Objective image quality was assessed using CT attenuation, standard deviation (SD), background noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) at five venous levels. Two radiologists independently rated subjective image quality and diagnostic confidence on 5-point Likert scales. Dose-length product (DLP), effective dose (ED), contrast medium volume, and iodine intake were also recorded and compared between protocols.

Results: In Group B, with ASIR-V fixed at 50%, CT attenuation, SD, background noise, SNR, and CNR decreased progressively as VMI energy increased. Among the seven VMI levels, 60 keV achieved the highest subjective image-quality score (all P < 0.05). At 60 keV, increasing ASIR-V reduced vascular SD and background noise and increased SNR and CNR. The 60 keV VMI plus 60% ASIR-V combination (Group B1) achieved the highest subjective score. Compared with Group A, Group B1 had significantly higher IVC CT attenuation and background noise (both P < 0.001), but SNR, CNR, and subjective image-quality scores did not differ significantly (all P > 0.05). Diagnostic-confidence scores for thrombosis, luminal stenosis, post-filter placement, and normal IVC findings were similar between Groups A and B1 (all P > 0.05). Relative to Group A, Group B1 reduced contrast medium volume, iodine intake, and ED by approximately 20.0%, 36.0%, and 12.51%, respectively (all P < 0.001).

Conclusion: The DECT protocol combining 60 keV VMI with 60% ASIR-V provided a favorable balance of image quality for IVC-CTA. The optimized protocol achieved SNR, CNR, subjective image quality, and diagnostic confidence similar to those of the conventional 120 kVp protocol while reducing contrast medium volume, iodine intake, and effective radiation dose.

Related

  1. Dual-Source Photon-Counting CT for Thoracic Arteries: Enhancing Image Quality and Diagnostic Assessability with Low-Energy Virtual Monoenergetic Imaging.
    Andreea I Nica, Christian Booz, Giuseppe M Bucolo +14
    Diagnostics (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Reducing Stent-Induced Blooming Artifacts Using Virtual Monoenergetic Imaging Reconstructions in a Superficial Femoral Artery Phantom: An In-Vitro Study
    Lisa Rutten, Lennart van de Velde, Cornelis H. Slump +4
    Cardiovascular Engineering and TechnologyPeer-reviewedCC BY 4.0Full textGeneral medicinePMC
  3. OCT-guided versus angiography-guided stent optimisation for post-interventional FFR in patients with complex coronary artery lesions: protocol for a multicentre, open-label, randomised controlled trial (PRECISION-COMPLEX)
    Seung Hun Lee, Min Chul Kim, Joon Ho Ahn +15
    BMJ OpenPeer-reviewedCC BY-NC 4.0Full textSurgery & anaesthesiaCrossref
  4. [Comment] Ligation site of the inferior mesenteric vein in laparoscopic radical resection of rectal cancer: a study protocol for a multicenter randomized-controlled trial
    Huo Ying, Li Jiannan
    结直肠肛门外科Peer-reviewedCC BY-NC-NDFull textOncologyDOAJ
  5. Quantitative comparison of virtual non-contrast and true non-contrast computed tomography pulmonary angiography images across eight thoracic tissue types: A retrospective cross-sectional study
    Jiulong Yan, Ziyu Zhao, Xin Zhou +5
    The Journal of International Medical ResearchPeer-reviewedCC BY-NC 4.0Full textGeneral medicinePMC
BibTeX
@article{deng2026optimized,
  title = {{Optimized dual-energy CT protocol for inferior vena cava CT angiography using 60 keV virtual monoenergetic imaging and 60% ASIR-V}},
  author = {Jiantao Deng and Xiaoping Fan and Qingwei Zhang and Jing Yan and Yong Li and Gaowu Yan and Linwei Zhao and Xiaocheng Shen and Qijia Peng and Ting Ma and Siyi Wu and Xiaohan Wang and Xisi HE and Morgan A. McClure and Anup Bhetuwal},
  journal = {Frontiers in Cardiovascular Medicine},
  year = {2026},
  month = oct,
  doi = {10.3389/fcvm.2026.1969018},
  url = {https://www.frontiersin.org/articles/10.3389/fcvm.2026.1969018/full},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Optimized dual-energy CT protocol for inferior vena cava CT angiography using 60 keV virtual monoenergetic imaging and 60% ASIR-V
AU  - Jiantao Deng
AU  - Xiaoping Fan
AU  - Qingwei Zhang
AU  - Jing Yan
AU  - Yong Li
AU  - Gaowu Yan
AU  - Linwei Zhao
AU  - Xiaocheng Shen
AU  - Qijia Peng
AU  - Ting Ma
AU  - Siyi Wu
AU  - Xiaohan Wang
AU  - Xisi HE
AU  - Morgan A. McClure
AU  - Anup Bhetuwal
PY  - 2026
DA  - 2026/10/29
JO  - Frontiers in Cardiovascular Medicine
DO  - 10.3389/fcvm.2026.1969018
UR  - https://www.frontiersin.org/articles/10.3389/fcvm.2026.1969018/full
AB  - Objective: To investigate the effects of a dual-energy CT (DECT) protocol combining virtual monoenergetic imaging (VMI) with adaptive statistical iterative reconstruction-V (ASIR-V) on image quality and radiation dose for inferior vena cava (IVC) CT angiography (CTA), and to compare the optimized protocol with a conventional 120 kVp protocol.  Methods: 120 consecutive patients undergoing IVC-CTA were enrolled and allocated sequentially to two groups ( n = 60 each). Group A underwent conventional 120 kVp scanning with 400 mgI/mL contrast medium at 1.5 mL/kg and 50% ASIR-V reconstruction. Group B underwent DECT (rapid 80/140 kVp switching) with 320 mgI/mL contrast medium at 1.2 mL/kg. In Group B, seven VMI datasets from 40 to 70 keV in 5 keV increments were first reconstructed with 50% ASIR-V. At 60 keV, images were reconstructed with filtered back projection (FBP; 0% ASIR-V) and ASIR-V levels from 20% to 100% in 20% increments. Objective image quality was assessed using CT attenuation, standard deviation (SD), background noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) at five venous levels. Two radiologists independently rated subjective image quality and diagnostic confidence on 5-point Likert scales. Dose-length product (DLP), effective dose (ED), contrast medium volume, and iodine intake were also recorded and compared between protocols.  Results: In Group B, with ASIR-V fixed at 50%, CT attenuation, SD, background noise, SNR, and CNR decreased progressively as VMI energy increased. Among the seven VMI levels, 60 keV achieved the highest subjective image-quality score (all P < 0.05). At 60 keV, increasing ASIR-V reduced vascular SD and background noise and increased SNR and CNR. The 60 keV VMI plus 60% ASIR-V combination (Group B1) achieved the highest subjective score. Compared with Group A, Group B1 had significantly higher IVC CT attenuation and background noise (both P < 0.001), but SNR, CNR, and subjective image-quality scores did not differ significantly (all P > 0.05). Diagnostic-confidence scores for thrombosis, luminal stenosis, post-filter placement, and normal IVC findings were similar between Groups A and B1 (all P > 0.05). Relative to Group A, Group B1 reduced contrast medium volume, iodine intake, and ED by approximately 20.0%, 36.0%, and 12.51%, respectively (all P < 0.001).  Conclusion: The DECT protocol combining 60 keV VMI with 60% ASIR-V provided a favorable balance of image quality for IVC-CTA. The optimized protocol achieved SNR, CNR, subjective image quality, and diagnostic confidence similar to those of the conventional 120 kVp protocol while reducing contrast medium volume, iodine intake, and effective radiation dose.
SN  - 2297-055X
ER  -