Skip to content
DraconiticResearch
Search Sources API
197,783 studies31 sourcesUpdated 23 min ago
PreprintCC BY-NCbioRxiv

LATEER: Low-Cost Open-Source Platform for Electrical Stimulation and TEER Measurement in Human Cardiomyocytes

  1. 1INEU-CONICET; FLENI;

Abstract

Electrical stimulation (ES) and transepithelial/transendothelial electrical resistance (TEER) measurements are essential techniques in cell biology and tissue engineering, yet commercial devices for these applications cost between USD 2,500-9,000 and typically offer only one functionality. We present LATEER (Low-cost Arduino-based TEER and Electrical stimulation device), an open-source hardware platform that combines both ES and TEER measurement capabilities at a total cost below USD 100. The device features four independent channels, configurable pulsatile signals (amplitude up to 8.2 V, frequency 0.1-500 Hz, pulse width [≥]0.1 ms), and a resistance measurement range of 300 {Omega} to 1 M{Omega}, with <5% error for R [≥] 4.7 k{Omega}. LATEER uses commercially available graphite pencil leads as electrodes ({approx}USD 2 vs. USD 350 for commercial Ag/AgCl electrodes), which demonstrated excellent biocompatibility in cell culture. The system includes 3D-printed electrode holders compatible with standard 12-well and 24-well plates, allowing microscope visualization without electrode removal, and a Python-based graphical user interface for parameter configuration and real-time data acquisition. Because the electrodes remain fixed in the plate lid and only a single cable enters the incubator, both stimulation and resistance measurement can run continuously under standard culture conditions (37 {degrees}C, 5% CO2) without removing the plate or repositioning the electrodes, avoiding the temperature excursions and placement variability inherent to manual chopstick measurements. Validation with human pluripotent stem cell-derived cardiomyocytes demonstrated reliable frequency capture (electrical pacing) of the contracting monolayer, with a capture threshold between 250 and 400 mV/mm and controlled pacing across the 0.5-5 Hz range. TEER functionality was verified with mesenchymal stem cells, where the device resolved cell-density-dependent differences in electrical resistance in real time. All design files, firmware, and software are freely available under the CERN-OHL-S v2 license, enabling replication and customization by research laboratories worldwide.

Related

  1. TEMPO-taVNS: a multimodal platform optimizing thermal, electrical, and mechanical auricular stimulation
    Damen Wilson, Maureen J. Shader, Steven R. Steinhubl +1
    Frontiers in NeurosciencePeer-reviewedCC BY 4.0NeuroscienceFrontiersCrossref
  2. Cav1.3-C-terminus Restores Electrical and Contractile Functions in hiPSC-derived Cardiomyocytes Model of Heart Failure
    Yvonne Sleiman, Jean-Baptiste Reisqs, Mohamed Boutjdir
    bioRxivPreprintCC BYFull textCell biologybioRxivPMC
  3. Ameliorating effects and mechanisms of therapeutic electrical stimulation on the recurrent laryngeal nerve injury model in rats
    Wei Zheng, Meiyi Han, Miaoxuan Shi +4
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textNeuroscienceCrossref
  4. Comparable phosphene size and contrast properties, but differing detection reliability for optogenetic versus electrical stimulation of macaque V1
    K. Liza, M. Falkowska-Kisiel, J. Cadena-Valencia +6
    bioRxivPreprintAll rights reservedFull textNeurosciencebioRxiv
  5. Altered Heart-Brain Interaction Related to Ecstatic Phenomena Induced by Insular Electrical Stimulation
    R. Tyrand, G.R. Iannotti, N.M. Sooter +8
    Brain StimulationPeer-reviewedCC BY 4.0Full textSystems & synthetic biologyHAL
BibTeX
@misc{delillo2026lateer,
  title = {{LATEER: Low-Cost Open-Source Platform for Electrical Stimulation and TEER Measurement in Human Cardiomyocytes}},
  author = {F. DeLillo and J. Smucler},
  howpublished = {bioRxiv},
  year = {2026},
  month = aug,
  doi = {10.64898/2026.08.06.743263},
  url = {https://www.biorxiv.org/content/10.64898/2026.08.06.743263v2},
  note = {CC BY-NC},
}
RIS
TY  - UNPB
TI  - LATEER: Low-Cost Open-Source Platform for Electrical Stimulation and TEER Measurement in Human Cardiomyocytes
AU  - F. DeLillo
AU  - J. Smucler
PY  - 2026
DA  - 2026/08/06
PB  - bioRxiv
DO  - 10.64898/2026.08.06.743263
UR  - https://www.biorxiv.org/content/10.64898/2026.08.06.743263v2
AB  - Electrical stimulation (ES) and transepithelial/transendothelial electrical resistance (TEER) measurements are essential techniques in cell biology and tissue engineering, yet commercial devices for these applications cost between USD 2,500-9,000 and typically offer only one functionality. We present LATEER (Low-cost Arduino-based TEER and Electrical stimulation device), an open-source hardware platform that combines both ES and TEER measurement capabilities at a total cost below USD 100. The device features four independent channels, configurable pulsatile signals (amplitude up to 8.2 V, frequency 0.1-500 Hz, pulse width [≥]0.1 ms), and a resistance measurement range of 300 {Omega} to 1 M{Omega}, with <5% error for R [≥] 4.7 k{Omega}. LATEER uses commercially available graphite pencil leads as electrodes ({approx}USD 2 vs. USD 350 for commercial Ag/AgCl electrodes), which demonstrated excellent biocompatibility in cell culture. The system includes 3D-printed electrode holders compatible with standard 12-well and 24-well plates, allowing microscope visualization without electrode removal, and a Python-based graphical user interface for parameter configuration and real-time data acquisition. Because the electrodes remain fixed in the plate lid and only a single cable enters the incubator, both stimulation and resistance measurement can run continuously under standard culture conditions (37 {degrees}C, 5% CO2) without removing the plate or repositioning the electrodes, avoiding the temperature excursions and placement variability inherent to manual chopstick measurements. Validation with human pluripotent stem cell-derived cardiomyocytes demonstrated reliable frequency capture (electrical pacing) of the contracting monolayer, with a capture threshold between 250 and 400 mV/mm and controlled pacing across the 0.5-5 Hz range. TEER functionality was verified with mesenchymal stem cells, where the device resolved cell-density-dependent differences in electrical resistance in real time. All design files, firmware, and software are freely available under the CERN-OHL-S v2 license, enabling replication and customization by research laboratories worldwide.
ER  -