Skip to content
DraconiticResearch
Search Sources API
201,683 studies31 sourcesUpdated 35 min ago
Peer-reviewedCC BY 4.0Journal of Abdominal Wall Surgery

Single-port robotic totally extraperitoneal inguinal hernia repair using a floating docking technique with the da Vinci SP system: feasibility across a spectrum of hernia complexity

  1. 1Department of Surgery, Catholic Kwandong University International St. Mary’s Hospital, Incheon, Republic of Korea

Abstract

The da Vinci SP system is applied to totally extraperitoneal (TEP) inguinal hernia repair, but clinical data remain limited. Full wrist articulation requires the instruments to extend beyond the cannula tip, which the preperitoneal space is too shallow to accommodate intracorporeally. We report a single-surgeon series using a floating docking configuration. We retrospectively reviewed 12 consecutive patients undergoing SP TEP repair. After a 2.5-cm infraumbilical incision and entry into the retrorectus space, the cannula was docked suspended approximately 9–10 cm above the skin, so that the instruments reached the operative field already articulating. Mesh reinforcement was performed in all patients. Patients were 11 men and 1 woman (91.7% male; mean age 57.2 ± 10.7 years), evenly split between sides; 10 primary and 2 (16.7%) recurrent, 8 indirect, 4 direct. Median operative and console times were 42.5 (IQR 38.8–46.8) and 40.0 min (IQR 33.8–42.2). All procedures were completed via a single port without conversion or additional trocars, including an incarcerated scrotal hernia and a recurrent hernia with dense adhesions requiring intracorporeal peritoneal closure. Mean hospital stay was 1.1 ± 0.5 days. Complications occurred in 3 patients (25.0%): fluid collection in all, urinary retention in one, managed conservatively. No recurrence occurred over a median follow-up of 6.9 months (IQR 4.1–8.7). SP TEP repair with floating docking was feasible across a range of hernia types and complexities, with no major early complications. Larger cohorts with longer follow-up are needed to assess recurrence and chronic pain.

Related

  1. Long-Term Outcomes of Laparoscopic Total Extraperitoneal Repair for Recurrent Inguinal Hernia
    M. Zafer Sabuncuoglu, Isa Sozen, Bilal Turan +6
    JSLS : Journal of the Society of Laparoscopic & Robotic SurgeonsPeer-reviewedLicence not statedFull textSurgery & anaesthesiaPMC
  2. Efficacy of laparoscopic transabdominal preperitoneal (TAPP) and totally extraperitoneal (TEP) repair in the treatment of bilateral inguinal hernia: a systematic review and meta-analysis
    Yulin Pan, Xiao Pang, Pan Shen +1
    Frontiers in SurgeryPeer-reviewedCC BY 4.0Full textSurgery & anaesthesiaPMC
  3. Unplanned Inpatient Admission After Intended Outpatient Total Extraperitoneal Inguinal Hernia Repair: Precautionary Monitoring or Clinically Relevant Morbidity?
    Julia Michel, Leonie Wesselmann, Fabian Nimczewski +3
    Journal of Clinical MedicinePeer-reviewedCC BY 4.0Surgery & anaesthesiaCrossref
  4. Case Report: A case of suprapiriform ureterosciatic hernia with ureteral incarceration treated by total extraperitoneal laparoscopic technique.
    Dan Luo
    Frontiers in surgeryPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
  5. Beyond Recurrence: Impact of Surgical Technique on Testicular Microcirculation After Inguinal Hernia Repair.
    Mehmet Emin Gönüllü, Fatih Gürsoy, İbrahim Feyyaz Naldemir +3
    BMC surgeryPeer-reviewedCC BY-NC-NDFull textSurgery & anaesthesiaEurope PMCDOAJ
BibTeX
@article{park2026singleport,
  title = {{Single-port robotic totally extraperitoneal inguinal hernia repair using a floating docking technique with the da Vinci SP system: feasibility across a spectrum of hernia complexity}},
  author = {Junhyung Park and Seong-Taek Oh and Jaeim Lee},
  journal = {Journal of Abdominal Wall Surgery},
  year = {2026},
  month = oct,
  doi = {10.3389/jaws.2026.17632},
  url = {https://doi.org/10.3389/jaws.2026.17632},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Single-port robotic totally extraperitoneal inguinal hernia repair using a floating docking technique with the da Vinci SP system: feasibility across a spectrum of hernia complexity
AU  - Junhyung Park
AU  - Seong-Taek Oh
AU  - Jaeim Lee
PY  - 2026
DA  - 2026/10/22
JO  - Journal of Abdominal Wall Surgery
DO  - 10.3389/jaws.2026.17632
UR  - https://doi.org/10.3389/jaws.2026.17632
AB  - The da Vinci SP system is applied to totally extraperitoneal (TEP) inguinal hernia repair, but clinical data remain limited. Full wrist articulation requires the instruments to extend beyond the cannula tip, which the preperitoneal space is too shallow to accommodate intracorporeally. We report a single-surgeon series using a floating docking configuration. We retrospectively reviewed 12 consecutive patients undergoing SP TEP repair. After a 2.5-cm infraumbilical incision and entry into the retrorectus space, the cannula was docked suspended approximately 9–10 cm above the skin, so that the instruments reached the operative field already articulating. Mesh reinforcement was performed in all patients. Patients were 11 men and 1 woman (91.7% male; mean age 57.2 ± 10.7 years), evenly split between sides; 10 primary and 2 (16.7%) recurrent, 8 indirect, 4 direct. Median operative and console times were 42.5 (IQR 38.8–46.8) and 40.0 min (IQR 33.8–42.2). All procedures were completed via a single port without conversion or additional trocars, including an incarcerated scrotal hernia and a recurrent hernia with dense adhesions requiring intracorporeal peritoneal closure. Mean hospital stay was 1.1 ± 0.5 days. Complications occurred in 3 patients (25.0%): fluid collection in all, urinary retention in one, managed conservatively. No recurrence occurred over a median follow-up of 6.9 months (IQR 4.1–8.7). SP TEP repair with floating docking was feasible across a range of hernia types and complexities, with no major early complications. Larger cohorts with longer follow-up are needed to assess recurrence and chronic pain.
SN  - 2813-2092
ER  -