Artificial Intelligence Across the Scoliosis Surgical Pathway: A Structured Narrative Review of Preoperative Planning, Instrumentation Support, and Postoperative Assessment
- 1Department of Neurosurgery, Polish-Mother’s Memorial Hospital Research Institute, 93-338 Lodz, Poland
- 2Independent Researcher, Luton LU2 0GS, UK
- 3Institute of Turbomachinery, Lodz University of Technology, 90-924 Lodz, Poland
Abstract
Background/Objectives: Artificial intelligence (AI) is increasingly investigated in scoliosis surgery, but its clinical readiness varies across applications. This structured narrative review examines AI applications across preoperative planning, intraoperative support, and postoperative assessment, focusing on methodological limitations, validation, and clinical utility. Methods: English-language publications were identified iteratively through PubMed and reference-list screening during approximately one year of manuscript preparation. The adopted publication window was January 1, 2022, to August 27, 2026. A.F. and R.K. selected and reviewed the literature. Twenty-two distinct primary studies were organized by clinical task and synthesized narratively. Qualitative appraisal was informed by PROBAST + AI, QUADAS-2, ROBINS-I, CLAIM, and relevant reporting guidelines; formal tool-based risk-of-bias ratings and quantitative pooling were not undertaken. PRISMA-ScR was not applied because this work was designed as a structured narrative review. Results: Preoperative applications included fusion-level selection, prediction of postoperative alignment, and risk stratification. Specialized systems demonstrated promising performance, including external validation, whereas general-purpose multimodal language models showed inconsistent agreement with expert surgical decisions. Applications informing intraoperative care primarily involved pedicle screw trajectory planning and patient-specific rod geometry rather than real-time adaptive guidance. Postoperative applications encompassed automated alignment measurements, instrumentation classification, implant monitoring, and complication prediction. A multicentre radiographic system achieved a mean absolute error of 2.7° for major-curve measurement, while selected growing-rod and vertebral body tethering studies reported measurement errors below 1 mm and 1°, respectively. However, evidence was frequently limited by small retrospective cohorts, insufficient external validation, incomplete calibration assessment, and limited evaluation of clinical impact. Mixed adult spinal deformity cohorts provided indirect evidence and were distinguished from scoliosis-specific populations. Conclusions: AI shows promise for automating defined imaging tasks and supporting individualized scoliosis surgical planning and follow-up. Technical accuracy alone does not establish clinical benefit. Prospective multicentre validation, transparent reporting, and evaluation of effects on decisions, complications, reoperations, and patient-reported outcomes are needed before routine implementation.
Related
- Artificial intelligence-assisted three-dimensional preoperative planning with patient-specific cutting guides versus conventional planning and instrumentation in total knee arthroplasty: a prospective exploratory cohort study.
- Artificial Intelligence Versus Manual Measurement of Spinopelvic Sagittal Parameters Across Preoperative, Postoperative, and Instrumented Spines: A Systematic Review of Diagnostic Accuracy, Failure Rates, and Inferred Surgical Planning Implications.
- Bias Mitigation Across the Healthcare Artificial Intelligence Lifecycle: A Structured Narrative Review
- Before Sepsis Strikes: Artificial Intelligence for Early Prediction of Postoperative Sepsis and Sepsis-Related Complications After Major Abdominal Surgery—A Systematic Review
- HemOncAgent: an artificial intelligence system for retrieving structured and narrative oncology knowledge
BibTeX
@article{kosinska2026artificial,
title = {{Artificial Intelligence Across the Scoliosis Surgical Pathway: A Structured Narrative Review of Preoperative Planning, Instrumentation Support, and Postoperative Assessment}},
author = {Róża Kosińska and Artur Fabijan and Robert Fabijan and Laura Kosińska and Emilia Nowosławska and Krzysztof Zakrzewski and Bartosz Polis},
journal = {Journal of Clinical Medicine},
year = {2026},
month = nov,
doi = {10.3390/jcm15229124},
url = {https://www.mdpi.com/2077-0383/15/22/9124},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Artificial Intelligence Across the Scoliosis Surgical Pathway: A Structured Narrative Review of Preoperative Planning, Instrumentation Support, and Postoperative Assessment
AU - Róża Kosińska
AU - Artur Fabijan
AU - Robert Fabijan
AU - Laura Kosińska
AU - Emilia Nowosławska
AU - Krzysztof Zakrzewski
AU - Bartosz Polis
PY - 2026
DA - 2026/11/01
JO - Journal of Clinical Medicine
DO - 10.3390/jcm15229124
UR - https://www.mdpi.com/2077-0383/15/22/9124
AB - Background/Objectives: Artificial intelligence (AI) is increasingly investigated in scoliosis surgery, but its clinical readiness varies across applications. This structured narrative review examines AI applications across preoperative planning, intraoperative support, and postoperative assessment, focusing on methodological limitations, validation, and clinical utility. Methods: English-language publications were identified iteratively through PubMed and reference-list screening during approximately one year of manuscript preparation. The adopted publication window was January 1, 2022, to August 27, 2026. A.F. and R.K. selected and reviewed the literature. Twenty-two distinct primary studies were organized by clinical task and synthesized narratively. Qualitative appraisal was informed by PROBAST + AI, QUADAS-2, ROBINS-I, CLAIM, and relevant reporting guidelines; formal tool-based risk-of-bias ratings and quantitative pooling were not undertaken. PRISMA-ScR was not applied because this work was designed as a structured narrative review. Results: Preoperative applications included fusion-level selection, prediction of postoperative alignment, and risk stratification. Specialized systems demonstrated promising performance, including external validation, whereas general-purpose multimodal language models showed inconsistent agreement with expert surgical decisions. Applications informing intraoperative care primarily involved pedicle screw trajectory planning and patient-specific rod geometry rather than real-time adaptive guidance. Postoperative applications encompassed automated alignment measurements, instrumentation classification, implant monitoring, and complication prediction. A multicentre radiographic system achieved a mean absolute error of 2.7° for major-curve measurement, while selected growing-rod and vertebral body tethering studies reported measurement errors below 1 mm and 1°, respectively. However, evidence was frequently limited by small retrospective cohorts, insufficient external validation, incomplete calibration assessment, and limited evaluation of clinical impact. Mixed adult spinal deformity cohorts provided indirect evidence and were distinguished from scoliosis-specific populations. Conclusions: AI shows promise for automating defined imaging tasks and supporting individualized scoliosis surgical planning and follow-up. Technical accuracy alone does not establish clinical benefit. Prospective multicentre validation, transparent reporting, and evaluation of effects on decisions, complications, reoperations, and patient-reported outcomes are needed before routine implementation.
SN - 2077-0383
ER -