Data Center Oscillation Isolation and Grid Support: Fundamental Limits and Source-Selective Control

Abstract

The grid integration of large data centers poses a growing power-system stability challenge. Rapidly varying computing demand can induce oscillations, while the facilities must provide a prescribed response to grid disturbances. Existing controls address load fluctuations and grid support but do not establish their jointly achievable performance. This paper derives fundamental limits and develops a source-selective controller for simultaneous oscillation isolation and grid support. A coupled closed-loop model gives a condition for distinguishing disturbance sources and reveals a direct isolation-support conflict under grid-import-power feedback alone; additional electrical measurements can remove this pointwise conflict but leave a conditional cross-frequency sensitivity limit. Guided by these limits, we design a local residual-feedback storage controller through convex frequency-domain optimization with stability, isolation, and grid-response constraints across operating points. Tests on a single-generator interconnection and a modified nine-bus network show stronger oscillation isolation than equal-order optimized comparators while meeting the prescribed grid response across operating points.

Related

  1. Data-Driven Control in Infinite-Dimensional Spaces: Fundamental Lemma and Applications
    Daniel López-Montero
    arXivPreprintCC BY 4.0Full textOptimisation & controlarXiv
  2. Finite-Memory Control of POMDPs: Fundamental Limits and Efficient Design
    Emrecan Kutay, Atilla Eryilmaz, Ness Shroff
    arXivPreprintCC BY 4.0Full textGeneral mathematicsarXiv
  3. Overcoming Fundamental Control Limitations in Powered Descent Flight through Robust Incremental Nonlinear Dynamic Inversion
    João T. Diz, Paulo Rosa, Pedro Simplício +3
    arXivPreprintarXiv licenceFull textOptimisation & controlarXiv
  4. Neyman-Pearson Classification with Indecisions: Simultaneous Control of Selective Type I and Type II Errors
    Bradley Rava, Bowen Gang
    arXivPreprintarXiv licenceFull textStatisticsarXiv
  5. An oscillation result for slightly perturbed trigonometric series
    Alain Haraux
    HALPreprintLicence Ouverte 2.0Full textAnalysis & PDEsHALarXiv
BibTeX
@misc{feng2026data,
  title = {{Data Center Oscillation Isolation and Grid Support: Fundamental Limits and Source-Selective Control}},
  author = {Cheng Feng},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.26812},
  eprint = {2610.26812},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.26812},
}
RIS
TY  - UNPB
TI  - Data Center Oscillation Isolation and Grid Support: Fundamental Limits and Source-Selective Control
AU  - Cheng Feng
PY  - 2026
DA  - 2026/10/19
PB  - arXiv
DO  - 10.48550/arxiv.2610.26812
UR  - https://arxiv.org/abs/2610.26812
AB  - The grid integration of large data centers poses a growing power-system stability challenge. Rapidly varying computing demand can induce oscillations, while the facilities must provide a prescribed response to grid disturbances. Existing controls address load fluctuations and grid support but do not establish their jointly achievable performance. This paper derives fundamental limits and develops a source-selective controller for simultaneous oscillation isolation and grid support. A coupled closed-loop model gives a condition for distinguishing disturbance sources and reveals a direct isolation-support conflict under grid-import-power feedback alone; additional electrical measurements can remove this pointwise conflict but leave a conditional cross-frequency sensitivity limit. Guided by these limits, we design a local residual-feedback storage controller through convex frequency-domain optimization with stability, isolation, and grid-response constraints across operating points. Tests on a single-generator interconnection and a modified nine-bus network show stronger oscillation isolation than equal-order optimized comparators while meeting the prescribed grid response across operating points.
ER  -