Skip to content
DraconiticResearch
Search Sources API
193,349 studies31 sourcesUpdated 49 min ago
Peer-reviewedCC BYEcological Indicators

A 25-year assessment of soil salinity in an arid oasis: Spatiotemporal validation and SHAP attribution

  1. 1Xinjiang Key Laboratory of Hydraulic Engineering Security and Water Disasters Prevention, Urumqi 830052, China; College of Hydraulic and Civil Engineering, Xinjiang Agricultural University, Urumqi 830052, China
  2. 2Xinjiang Key Laboratory of Hydraulic Engineering Security and Water Disasters Prevention, Urumqi 830052, China; College of Hydraulic and Civil Engineering, Xinjiang Agricultural University, Urumqi 830052, China; Corresponding author at: College of Hydraulic and Civil Engineering, Xinjiang Agricultural University, Urumqi 830052, China.
  3. 3Xinjiang Key Laboratory of Hydraulic Engineering Security and Water Disasters Prevention, Urumqi 830052, China; College of Hydraulic and Civil Engineering, Xinjiang Agricultural University, Urumqi 830052, China; Xinjiang Water Conservancy Development Investment (Group) Co., Ltd., Urumqi 830000, China

Abstract

Long-term soil salinity mapping in arid oases is vulnerable to spatial dependence and interannual shifts, yet transfer to unsampled areas and years is rarely tested explicitly. We combined 1107 quality-controlled topsoil observations from the Yanqi Basin, China (2000, 2005, 2015, 2020, and 2025), with 30 environmental covariates. Ten algorithms and five input strategies were compared using site-grouped five-fold, 15-km spatial-block five-fold, and leave-one-year-out (LOYO) validation. Extremely Randomized Trees (ERT) provided the most stable overall performance (R 2 = 0.602, 0.597, and 0.501), whereas Transformer performed best under LOYO (R 2 = 0.523), showing that algorithm rankings depended on the transfer scenario. PCC, VIP, GRA, and GBM feature selection produced no consistent gains; ERT fitted with all 30 predictors was therefore used for mapping. Within the common valid support, the area with SSC ≥ 6 g kg −1 increased from 23.65% in 2000 to 36.41% in 2005, declined to 22.40% in 2015, and rose to 33.88% in 2025, indicating an expansion–relief–reintensification pattern. ERT-SHAP identified SI3, SI1, and Int1 as the leading predictive indicators, while groundwater depth added little independent information after the other covariates were included. ERT systematically underestimated SSC ≥ 10 g kg −1 (spatial-block bias, −4.426 g kg −1 ), requiring caution at the upper end of the observed range. The framework supports reproducible regional comparison and potential hotspot screening by combining spatiotemporal transfer tests, high-value diagnostics, attribution, and long-term mapping.

Related

  1. Long-term ozone formation sensitivity in China: spatiotemporal evolution and machine learning attribution
    Jinglan Lin, Liqing Wu, Chujun Chen +4
    Atmospheric chemistry and physicsPeer-reviewedCC BY5 citedAtmospheric science & meteorologyOpenAlex
  2. An integrated framework for agroclimatic, salinity, and groundwater assessment in the Jizzakh Region, Uzbekistan
    B. Amanov, A. Ghirardelli, A. Sherov +3
    iSciencePeer-reviewedCC BY 4.0Full textHydrology & soilsCell PressCrossrefEurope PMC
  3. Bay Assessment Model: A Python-based Salinity Projection Tool for Florida Bay, USA
    Erik Stabenau, Joseph Park
    arXivPreprintCC BY 4.0Full textAtmospheric science & meteorologyGeophysics & seismologyarXiv
  4. Explainable spatiotemporal Graph Neural Networks: Multi-City PM2.5 forecasting in Bangladesh with geographic graph topology validation
    Pritom Ray Nobin
    PLOS OnePeer-reviewedCC BY 4.0Full textEnvironmental chemistryAtmospheric science & meteorologyPLOS
  5. Structural diagnosis and evolution of urban resilience in dryland oasis urban agglomerations from an eco-immunological perspective
    Yingyue Hou, Qiang Hu, Ümüt Halik
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textEnvironmental science & pollutionCrossref
BibTeX
@article{li202625year,
  title = {{A 25-year assessment of soil salinity in an arid oasis: Spatiotemporal validation and SHAP attribution}},
  author = {Zhipeng Li and Pengnian Yang and Youyang Luo and Fanghong Han and Yongpeng Wang and Long Zhou},
  journal = {Ecological Indicators},
  year = {2026},
  month = oct,
  doi = {10.1016/j.ecolind.2026.115475},
  url = {https://doi.org/10.1016/j.ecolind.2026.115475},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - A 25-year assessment of soil salinity in an arid oasis: Spatiotemporal validation and SHAP attribution
AU  - Zhipeng Li
AU  - Pengnian Yang
AU  - Youyang Luo
AU  - Fanghong Han
AU  - Yongpeng Wang
AU  - Long Zhou
PY  - 2026
DA  - 2026/10/23
JO  - Ecological Indicators
DO  - 10.1016/j.ecolind.2026.115475
UR  - https://doi.org/10.1016/j.ecolind.2026.115475
AB  - Long-term soil salinity mapping in arid oases is vulnerable to spatial dependence and interannual shifts, yet transfer to unsampled areas and years is rarely tested explicitly. We combined 1107 quality-controlled topsoil observations from the Yanqi Basin, China (2000, 2005, 2015, 2020, and 2025), with 30 environmental covariates. Ten algorithms and five input strategies were compared using site-grouped five-fold, 15-km spatial-block five-fold, and leave-one-year-out (LOYO) validation. Extremely Randomized Trees (ERT) provided the most stable overall performance (R 2 = 0.602, 0.597, and 0.501), whereas Transformer performed best under LOYO (R 2 = 0.523), showing that algorithm rankings depended on the transfer scenario. PCC, VIP, GRA, and GBM feature selection produced no consistent gains; ERT fitted with all 30 predictors was therefore used for mapping. Within the common valid support, the area with SSC ≥ 6 g kg −1 increased from 23.65% in 2000 to 36.41% in 2005, declined to 22.40% in 2015, and rose to 33.88% in 2025, indicating an expansion–relief–reintensification pattern. ERT-SHAP identified SI3, SI1, and Int1 as the leading predictive indicators, while groundwater depth added little independent information after the other covariates were included. ERT systematically underestimated SSC ≥ 10 g kg −1 (spatial-block bias, −4.426 g kg −1 ), requiring caution at the upper end of the observed range. The framework supports reproducible regional comparison and potential hotspot screening by combining spatiotemporal transfer tests, high-value diagnostics, attribution, and long-term mapping.
SN  - 1470-160X
SN  - 1872-7034
ER  -