Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 20 min ago
Peer-reviewedCC BY 4.0Frontiers in Cardiovascular Medicine

Pacing during TAVR through a coronary wire in the coronary artery and left ventricular wire

  1. 1Department of Cardiology, Hainan General Hospital
  2. 2Hainan Affiliated Hospital , Hainan Medical University
  3. 3Hainan Clinical Research Center for Cardiology

Abstract

The conventional pacing-over-the-wire technique in transcatheter aortic valve replacement (TAVR) results in high impedance and voltage thresholds, which may cause loss of capture and valve embolisation. Our team reported that coronary wire pacing, in which a coronary wire is placed in the left coronary artery (anode) and a left ventricular wire (cathode), is associated with extremely low impedance and pacing voltage thresholds in patients who are at high risk of coronary obstruction. Moreover, coronary wire pacing is simple and reliable. In this study, we illustrate the coronary wire pacing technique in a patient to provide a new approach to wire pacing in TAVR.

Related

  1. Standardized 4-step surgical approach to address atrial fibrillation during coronary artery bypass grafting in a patient with severely reduced left ventricular function: a case report
    Johannes Gökler, Philipp Szalkiewicz, Ilinca Damian +3
    Frontiers in Cardiovascular MedicinePeer-reviewedCC BY 4.0Full textCardiovascular medicineCrossref
  2. Perioperative temporary microaxial left ventricular assist device support in patients with low ejection fraction undergoing coronary artery bypass grafting
    Allyson Howard-Green, Deevya Raman, Mark Cordell +9
    Frontiers in cardiovascular medicinePeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
  3. Multicentre medicoeconomic evaluation of cardiac magnetic resonance imaging for predicting coronary artery disease in left ventricular dysfunction: The CAMAREC study design
    Louis-Marie Desroche, Damien Mandry, Gregory Ducrocq +14
    Archives of cardiovascular diseasesPeer-reviewedLicence not stated3 citedGeneral biologyCardiovascular medicineHAL
  4. Restitution properties during ventricular fibrillation and the effects of cardiac pacing location on ventricular electrophysiology in the rabbit heart.
    Bethan Roper-Jones, Emily Allen, Rachel L Sutcliffe +2
    Experimental physiologyPeer-reviewedCC BYFull textCardiovascular medicineEurope PMCPMC
  5. Saphenous Vein Graft-to-Pulmonary Artery Fistula Presenting With Coronary Ischemia and Right Ventricular Dysfunction
    Tugba Aktemur Özalp
    JACC Case ReportsPeer-reviewedCC BY-NC-ND 4.0Full text1 citedSurgery & anaesthesiaPMCDOAJ
BibTeX
@article{ma2026pacing,
  title = {{Pacing during TAVR through a coronary wire in the coronary artery and left ventricular wire}},
  author = {Ruisong Ma and Lili Zhang and Wang Liao and Sheng Wang},
  journal = {Frontiers in Cardiovascular Medicine},
  year = {2026},
  month = oct,
  doi = {10.3389/fcvm.2026.1955852},
  url = {https://www.frontiersin.org/articles/10.3389/fcvm.2026.1955852/full},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - Pacing during TAVR through a coronary wire in the coronary artery and left ventricular wire
AU  - Ruisong Ma
AU  - Lili Zhang
AU  - Wang Liao
AU  - Sheng Wang
PY  - 2026
DA  - 2026/10/22
JO  - Frontiers in Cardiovascular Medicine
DO  - 10.3389/fcvm.2026.1955852
UR  - https://www.frontiersin.org/articles/10.3389/fcvm.2026.1955852/full
AB  - The conventional pacing-over-the-wire technique in transcatheter aortic valve replacement (TAVR) results in high impedance and voltage thresholds, which may cause loss of capture and valve embolisation. Our team reported that coronary wire pacing, in which a coronary wire is placed in the left coronary artery (anode) and a left ventricular wire (cathode), is associated with extremely low impedance and pacing voltage thresholds in patients who are at high risk of coronary obstruction. Moreover, coronary wire pacing is simple and reliable. In this study, we illustrate the coronary wire pacing technique in a patient to provide a new approach to wire pacing in TAVR.
SN  - 2297-055X
ER  -