Skip to content
DraconiticResearch
Search Sources API
181,716 studies31 sourcesUpdated 31 min ago
Peer-reviewedCC BY-NC-NDNature communications

Vacuum ultraviolet dual-comb spectroscopy.

  1. 1James C. Wyant College of Optical Sciences, University of Arizona, Tucson, AZ, USA.
  2. 2Department of Physics, University of Arizona, Tucson, AZ, USA.
  3. 3James C. Wyant College of Optical Sciences, University of Arizona, Tucson, AZ, USA. [email protected].

Abstract

The optical frequency comb has made a significant impact in precision spectroscopy and on our ability to probe atomic, molecular and, recently, nuclear transitions to further our understanding of their fundamental properties and how their dynamics and complex interactions affect the observed world. To expand the energy scales and types of systems that can be studied, frequency comb sources from terahertz to vacuum ultraviolet frequencies and beyond have been pursued. Dual-comb spectroscopy, enabled by the development of these frequency comb sources, allows broadband absorption measurements of complicated spectra, exceeding the limitations of direct, single-comb spectroscopy. To date, however, the dual-comb approach has not been able to directly access many important transitions that lie at challenging vacuum ultraviolet wavelengths. Here, we demonstrate dual-comb spectroscopy in the vacuum ultraviolet utilizing intracavity high harmonic generation. This multi-harmonic source is used to measure molecular absorbance spectra at λ = 210 nm and λ = 149 nm from room-temperature samples of acetylene and ammonia, respectively. These measurements resolve the Doppler broadened structure of congested molecular spectra with absolute frequency accuracy. Noise contributions to the vacuum ultraviolet dual-comb spectroscopy measurements are characterized, guiding future efforts and technological development in this region.

Related

  1. Dual-comb spectroscopy for spatially resolved hydrogen combustion diagnostics over a wide temperature range
    Meng-Zhe Lian, Wei-Fan Hu, Yu-Xuan Cao +10
    Optics ExpressPeer-reviewedPublisher termsPhysical chemistryCrossref
  2. Vacuum-Ultraviolet-Induced Fragmentation of Furan Studied by Photon-Induced Fluorescence Spectroscopy
    Tomasz J. Wasowicz, Marcin Dampc, Marcello Coreno +1
    MoleculesPeer-reviewedCC BY 4.0General chemistryCrossref
  3. Fluorination modulation theory for vacuum-ultraviolet nonlinear optical crystals (I): foundation and framework
    Zhihua Yang, Abudukadi Tudi, Min Zhang +3
    National Science ReviewPeer-reviewedCC BY10 citedMaterials & polymersOpenAlex
  4. Single-Cavity Dual-Comb Mueller Polarimetry for Material-Aware LiDAR
    Hani J. Kbashi, Sergey Sergeyev
    ACS omegaPeer-reviewedCC BYFull textGeneral chemistryEurope PMCCrossref
  5. In Situ Ultraviolet Fluorescence Spectroscopy for the Characterization of Translucent Calcite Coatings over Prehistoric Cave Art
    Yohan Boulard, Thiéry Guillou, Carole Fritz +3
    ACS omegaPeer-reviewedCC BY-NC-NDFull textGeneral chemistryEurope PMCHAL
BibTeX
@article{mccauley2026vacuum,
  title = {{Vacuum ultraviolet dual-comb spectroscopy.}},
  author = {John J McCauley and Dylan P Tooley and R Jason Jones},
  journal = {Nature communications},
  year = {2026},
  month = sep,
  doi = {10.1038/s41467-026-77763-y},
  url = {https://europepmc.org/article/MED/42907442},
  note = {CC BY-NC-ND},
}
RIS
TY  - JOUR
TI  - Vacuum ultraviolet dual-comb spectroscopy.
AU  - John J McCauley
AU  - Dylan P Tooley
AU  - R Jason Jones
PY  - 2026
DA  - 2026/09/21
JO  - Nature communications
DO  - 10.1038/s41467-026-77763-y
UR  - https://europepmc.org/article/MED/42907442
AB  - The optical frequency comb has made a significant impact in precision spectroscopy and on our ability to probe atomic, molecular and, recently, nuclear transitions to further our understanding of their fundamental properties and how their dynamics and complex interactions affect the observed world. To expand the energy scales and types of systems that can be studied, frequency comb sources from terahertz to vacuum ultraviolet frequencies and beyond have been pursued. Dual-comb spectroscopy, enabled by the development of these frequency comb sources, allows broadband absorption measurements of complicated spectra, exceeding the limitations of direct, single-comb spectroscopy. To date, however, the dual-comb approach has not been able to directly access many important transitions that lie at challenging vacuum ultraviolet wavelengths. Here, we demonstrate dual-comb spectroscopy in the vacuum ultraviolet utilizing intracavity high harmonic generation. This multi-harmonic source is used to measure molecular absorbance spectra at λ = 210 nm and λ = 149 nm from room-temperature samples of acetylene and ammonia, respectively. These measurements resolve the Doppler broadened structure of congested molecular spectra with absolute frequency accuracy. Noise contributions to the vacuum ultraviolet dual-comb spectroscopy measurements are characterized, guiding future efforts and technological development in this region.
SN  - 2041-1723
ER  -