Skip to content
DraconiticResearch
Search Sources API
197,768 studies31 sourcesUpdated 41 min ago
Peer-reviewedCC BY-NC-NDBMC chemistry

Eco-sustainable organic solvent-free spectrophotometric method for the concurrent determination of a ternary pharmaceutical mixture.

4 affiliations
  1. 1Pharmaceutical Chemistry Department, Faculty of Pharmacy, Egyptian Russian University, Badr City, 11829, Cairo, Egypt. [email protected].
  2. 2Pharmaceutical Chemistry Department, Faculty of Pharmacy, Egyptian Russian University, Badr City, 11829, Cairo, Egypt. [email protected].
  3. 3Analytical Chemistry Department, Faculty of Pharmacy, Zagazig University, Zagazig, 44519, Egypt.
  4. 4Pharmaceutical Chemistry Department, Faculty of Pharmacy, Egyptian Russian University, Badr City, 11829, Cairo, Egypt.

Abstract

In recent years, green analytical chemistry has become essential in pharmaceutical research, aiming to mitigate environmental hazards associated with conventional analytical practices. The current focus lies in optimizing analytical methods to achieve both environmental and economic sustainability. In this framework, three environmentally sustainable spectrophotometric methods were developed for simultaneous analysis of three co-formulated drugs: acetaminophen, dextromethorphan hydrobromide, and pseudoephedrine hydrochloride, which are often used to alleviate symptoms associated with COVID-19. The employed spectrophotometric methodologies include the double divisor-ratio spectra derivative method, the mean centering of double divisor ratio spectra method, and the dual wavelength in ratio spectrum method. The innovative techniques displayed good linearity within 25-350 µg/mL for dextromethorphan hydrobromide, 2-24 µg/mL for acetaminophen, and 100-1400 µg/mL for pseudoephedrine hydrochloride. The environmental sustainability of the proposed methods was evaluated using the Analytical Eco-Scale, analytical greenness metric, and the Green Analytical Procedure Index. Furthermore, complementary evaluations of blueness and whiteness were conducted through the Blue Applicability Grade Index and the Red Green Blue 12 metric, respectively. The collective outcomes of all evaluation metrics clearly demonstrated that the proposed methods possess enhanced environmental compatibility and sustainability relative to the existing techniques. The proposed methods were fully validated according to the International Conference on Harmonization recommendations. The developed methods offered a cost-effective and eco-friendly approach for concurrent determination of acetaminophen, dextromethorphan hydrobromide, and pseudoephedrine hydrochloride in their bulk substances, and pharmaceutical formulations.

Related

  1. Solid-phase extraction of organic dyes using a nickel trimesinate-based hybrid metal-organic framework combined with spectrophotometric determination
    I. Е. Uflyand, V. N. Naumkina, A. Y. Litvinova +3
    Scientific ReportsPeer-reviewedCC BY 4.0Full textAnalytical chemistryCrossref
  2. First Application of 3,5-Dinitrocatechol and Benzalkonium Chloride in Cloud Point Extraction: Spectrophotometric Determination of Vanadium(V)
    Petya Racheva, Antoaneta Saravanska, Andrea Gajdošová +4
    Molecules (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral chemistryEurope PMC
  3. Sustainable signal-processing spectrophotometric approaches for synchronous analysis of novel antiallergic combination: evaluation via multi-metric sustainability indices
    Heidi R. Abd El-Hadi, Michael Gamal Fawzy
    Scientific ReportsPeer-reviewedCC BY 4.0Full textAnalytical chemistryCrossref
  4. Green Micelle-Enhanced Spectrofluorimetric Determination of Gefitinib in Pharmaceutical Tablets Using Cremophor RH 40: Response-Surface Optimization and Time-Dependent Density Functional Theory (TD-DFT) Interpretation
    Ahmed H. Bakheit, Abdullah M. A. Alzaid, Abdulrahman A. Almajed
    International Journal of Molecular SciencesPeer-reviewedCC BY 4.0Analytical chemistryCrossref
  5. Development and validation of a GC-MS method for the determination of ethylene glycol and diethylene glycol in pharmaceutical syrups.
    Muhammad Amirul Amil, Muhammad Shahariz Mohamad Adzib, Nur Baizura Bujang +5
    BMC pharmacology & toxicologyPeer-reviewedCC BY-NC-NDFull textAnalytical chemistryEurope PMC
BibTeX
@article{hamdy2026ecosustainable,
  title = {{Eco-sustainable organic solvent-free spectrophotometric method for the concurrent determination of a ternary pharmaceutical mixture.}},
  author = {Abdallah M Hamdy and Esraa M Meselhy and Magda M El Henawee and Hisham Hashem and Hany Ibrahim},
  journal = {BMC chemistry},
  year = {2026},
  month = oct,
  doi = {10.1186/s13065-026-01903-0},
  url = {https://europepmc.org/article/MED/42907898},
  note = {CC BY-NC-ND},
}
RIS
TY  - JOUR
TI  - Eco-sustainable organic solvent-free spectrophotometric method for the concurrent determination of a ternary pharmaceutical mixture.
AU  - Abdallah M Hamdy
AU  - Esraa M Meselhy
AU  - Magda M El Henawee
AU  - Hisham Hashem
AU  - Hany Ibrahim
PY  - 2026
DA  - 2026/10/21
JO  - BMC chemistry
DO  - 10.1186/s13065-026-01903-0
UR  - https://europepmc.org/article/MED/42907898
AB  - In recent years, green analytical chemistry has become essential in pharmaceutical research, aiming to mitigate environmental hazards associated with conventional analytical practices. The current focus lies in optimizing analytical methods to achieve both environmental and economic sustainability. In this framework, three environmentally sustainable spectrophotometric methods were developed for simultaneous analysis of three co-formulated drugs: acetaminophen, dextromethorphan hydrobromide, and pseudoephedrine hydrochloride, which are often used to alleviate symptoms associated with COVID-19. The employed spectrophotometric methodologies include the double divisor-ratio spectra derivative method, the mean centering of double divisor ratio spectra method, and the dual wavelength in ratio spectrum method. The innovative techniques displayed good linearity within 25-350 µg/mL for dextromethorphan hydrobromide, 2-24 µg/mL for acetaminophen, and 100-1400 µg/mL for pseudoephedrine hydrochloride. The environmental sustainability of the proposed methods was evaluated using the Analytical Eco-Scale, analytical greenness metric, and the Green Analytical Procedure Index. Furthermore, complementary evaluations of blueness and whiteness were conducted through the Blue Applicability Grade Index and the Red Green Blue 12 metric, respectively. The collective outcomes of all evaluation metrics clearly demonstrated that the proposed methods possess enhanced environmental compatibility and sustainability relative to the existing techniques. The proposed methods were fully validated according to the International Conference on Harmonization recommendations. The developed methods offered a cost-effective and eco-friendly approach for concurrent determination of acetaminophen, dextromethorphan hydrobromide, and pseudoephedrine hydrochloride in their bulk substances, and pharmaceutical formulations.
SN  - 2661-801X
ER  -