Skip to content
DraconiticResearch
Search Sources API
197,768 studies31 sourcesUpdated 11 min ago
Peer-reviewedCC BY 4.0iScience

A systematic approach to quantitative nanoscale mass spectrometry using atomic force microscopy

Abstract

Atomic force microscopy (AFM) enables mass sensing through resonance-frequency changes of microcantilevers, but quantitative measurements can be affected by calibration and environmental factors. Here, we investigated whether a calibrated AFM cantilever and controlled mass loading could provide nanogram-scale mass estimation. Cantilevers were cleaned and calibrated by force-distance measurements, and resonance acquisition parameters were optimized under ambient conditions. UV-curable resin droplets were locally deposited on the cantilever to generate mass loading, and resonance-frequency shifts were measured and analyzed using a mass-spring model and finite-element simulations. Increasing resin mass produced progressive decreases in resonance frequency, demonstrating a consistent relationship between mass loading and cantilever resonance behavior. Finite-element simulations reproduced the resonance responses and supported the mass estimates obtained from the experimental measurements. These findings establish a calibration and modeling framework for resonance-based mass quantification using conventional AFM cantilevers and provide a basis for extending quantitative mass analysis to microstructures and biological assemblies.

Related

  1. Multiplexed Enzyme Activity Microscopy by Semi-quantitative, Ratiometric Enzyme Activity MALDI Mass Spectrometry Imaging.
    Hamidreza Hojjat, Petra Henklein, Akvile Haeckel +10
    ACS measurement science auPeer-reviewedCC BYFull textPhysical chemistryEurope PMC
  2. A high-sensitivity resistance bridge for nanoscale thermal microscopy
    Wilfrid Poirier, Victor Guillemot, Mohammed Mghalfi +2
    HALPreprintLicence not statedFull textMaterials & polymersHAL
  3. Automated Full-Spectrum Multivariate Calibration for Quantitative Glow Discharge Optical Emission Spectrometry
    Marius R. Bittermann, Beatrice Battistella, Volker Hoffmann +4
    ChemRxivPreprintLicence not statedGeneral chemistryChemRxiv
  4. Quantitative Cryogenic Orbitrap Secondary Ion Mass Spectrometry for structural characterization of lipid nanoparticles
    Joseph W Roberts, Anna Kotowska, Eduardo Aguilar-Bejarano +13
    ChemRxivPreprintLicence not statedGeneral chemistryChemRxiv
  5. Quantitative Multiplexed Rapid Immunoprecipitation and Mass Spectrometry of Endogenous Proteins (qPLEX‐RIME) in Cell Lines
    Soleilmane Omarjee, Evangelia K. Papachristou, Chandra Sekhar Reddy Chilamakuri +6
    Current protocolsPeer-reviewedCC BYFull textPhysical chemistryEurope PMCPMC
BibTeX
@article{kwon2026systematic,
  title = {{A systematic approach to quantitative nanoscale mass spectrometry using atomic force microscopy}},
  author = {Sangwoo Kwon and Kyung Sook Kim},
  journal = {iScience},
  year = {2026},
  month = oct,
  doi = {10.1016/j.isci.2026.117900},
  url = {https://www.cell.com/iscience/fulltext/S2589-0042(26)03283-9},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - A systematic approach to quantitative nanoscale mass spectrometry using atomic force microscopy
AU  - Sangwoo Kwon
AU  - Kyung Sook Kim
PY  - 2026
DA  - 2026/10/14
JO  - iScience
DO  - 10.1016/j.isci.2026.117900
UR  - https://www.cell.com/iscience/fulltext/S2589-0042(26)03283-9
AB  - Atomic force microscopy (AFM) enables mass sensing through resonance-frequency changes of microcantilevers, but quantitative measurements can be affected by calibration and environmental factors. Here, we investigated whether a calibrated AFM cantilever and controlled mass loading could provide nanogram-scale mass estimation. Cantilevers were cleaned and calibrated by force-distance measurements, and resonance acquisition parameters were optimized under ambient conditions. UV-curable resin droplets were locally deposited on the cantilever to generate mass loading, and resonance-frequency shifts were measured and analyzed using a mass-spring model and finite-element simulations. Increasing resin mass produced progressive decreases in resonance frequency, demonstrating a consistent relationship between mass loading and cantilever resonance behavior. Finite-element simulations reproduced the resonance responses and supported the mass estimates obtained from the experimental measurements. These findings establish a calibration and modeling framework for resonance-based mass quantification using conventional AFM cantilevers and provide a basis for extending quantitative mass analysis to microstructures and biological assemblies.
SN  - 2589-0042
ER  -