Skip to content
DraconiticResearch
Search Sources API
182,469 studies31 sourcesUpdated 37 min ago
PreprintCC BYbioRxiv

Patient-Centric Development of a Low-Volume, Low-Viscosity, Once Every 4 Weeks (Q4W) Autoinjector Combination Product for Povetacicept

  1. 1Vertex Pharmaceuticals Incorporated

Abstract

Biologic therapies delivered subcutaneously (SC) are increasingly moving toward at-home self-administration using drug-device combination products. This shift places greater emphasis on the patient experience, and factors such as dose volume, injection time, dosing frequency, viscosity, injection force, and ease of use can affect treatment burden. This article focuses on the impact of balancing high protein concentration with low viscosity during drug product formulation development for an improved patient experience for povetacicept, an investigational, subcutaneously administered dual B-cell activating factor (BAFF) and a proliferation-inducing ligand (APRIL) inhibitor being developed for the treatment of multiple kidney diseases, including IgA nephropathy (IgAN). For povetacicept, formulation and device considerations were integrated throughout development. Studies evaluated protein concentration, dose volume, viscosity, injection force, injection time, and usability, in addition to standard stability, to develop a low-volume Q4W autoinjector. The selected 175 mg/mL formulation delivers an 80 mg dose in 0.46 mL. The viscosity was no more than 10 cP at 15-25{degrees}C and in a 1 mL prefilled syringe, the average glide force was 6 N, and the injection time at a constant force of 20 N was < 2 seconds. The same prefilled syringe was incorporated into an autoinjector with an injection time of less than 2 seconds in air. We conducted a limited assessment of an approved treatment for IgAN (Voyxact) administered via prefilled syringe (PFS) for effects of viscosity, fill volume and syringe configuration under the same experimental conditions. The viscosity at room temperature was 16 cP, with an average glide force of 27N and injection time of 19 seconds for the 2 mL dose. In conclusion, povetacicept was designed to support convenient and user-friendly at-home self-administration through Q4W dosing, a low injection volume, a low viscosity formulation, rapid delivery, and an easy-to-use autoinjector. This integrated formulation and device development approach demonstrates how patient-centric considerations can be incorporated in combination product development. Together, these attributes have the potential to reduce the practical burden associated with repeated, long-term treatment for IgAN patients.

Related

  1. The potential of AI inspired approaches for patient monitoring in drug development for Huntington's disease: capturing the digital exhaust for activities of daily living.
    Amit Khanna, Graham Jones
    Frontiers in molecular medicinePeer-reviewedCC BYFull text1 citedNeuroscienceEurope PMC
  2. Development and preliminary validation of a patient-report experience measure of acute oncology: The PREMAC study
    Richard Wagland, Anna Hurley-Wallace, John Defty +2
    PLOS OnePeer-reviewedCC BY 4.0Full textNeuroscienceStatisticsPLOSPMC
  3. Development and psychometric properties evaluation of individualized patient education tool: An exploratory sequential mixed-methods study protocol
    Sevda Gardashkhani, Mansour Ghafourifard, Akram Ghahramanian +2
    PLOS OnePeer-reviewedCC BYFull textGeneral biologyStatisticsPLOSEurope PMCPMC
  4. Rapid Assessment of Therapeutic Empathy (RATE): Development of a universal single-item empathy scale and validation of the patient-reported version
    Amber Bennett-Weston, John Maltby, Kamlesh Khunti +5
    PLOS OnePeer-reviewedCC BY 4.0Full textNeuroscienceClinical trials & evidence synthesisPLOS
  5. The stability investigation of variable viscosity control in the human‐robot interaction
    Lin Dong, Nicolas Perrin, Florian Richer +2
    The International Journal of Medical Robotics and Computer Assisted SurgeryPeer-reviewedHAL deposit licenceFull text4 citedSystems & synthetic biologyHAL
BibTeX
@misc{lucas2026patientcentric,
  title = {{Patient-Centric Development of a Low-Volume, Low-Viscosity, Once Every 4 Weeks (Q4W) Autoinjector Combination Product for Povetacicept}},
  author = {J. Lucas and J. A. Floyd and E. Hickey and C. Perez-Lopes and R. Lehane and M. Chawla and M. Salema and G. Graffius},
  howpublished = {bioRxiv},
  year = {2026},
  month = oct,
  doi = {10.64898/2026.10.20.760382},
  url = {https://www.biorxiv.org/content/10.64898/2026.10.20.760382v1},
  note = {CC BY},
}
RIS
TY  - UNPB
TI  - Patient-Centric Development of a Low-Volume, Low-Viscosity, Once Every 4 Weeks (Q4W) Autoinjector Combination Product for Povetacicept
AU  - J. Lucas
AU  - J. A. Floyd
AU  - E. Hickey
AU  - C. Perez-Lopes
AU  - R. Lehane
AU  - M. Chawla
AU  - M. Salema
AU  - G. Graffius
PY  - 2026
DA  - 2026/10/20
PB  - bioRxiv
DO  - 10.64898/2026.10.20.760382
UR  - https://www.biorxiv.org/content/10.64898/2026.10.20.760382v1
AB  - Biologic therapies delivered subcutaneously (SC) are increasingly moving toward at-home self-administration using drug-device combination products. This shift places greater emphasis on the patient experience, and factors such as dose volume, injection time, dosing frequency, viscosity, injection force, and ease of use can affect treatment burden. This article focuses on the impact of balancing high protein concentration with low viscosity during drug product formulation development for an improved patient experience for povetacicept, an investigational, subcutaneously administered dual B-cell activating factor (BAFF) and a proliferation-inducing ligand (APRIL) inhibitor being developed for the treatment of multiple kidney diseases, including IgA nephropathy (IgAN). For povetacicept, formulation and device considerations were integrated throughout development. Studies evaluated protein concentration, dose volume, viscosity, injection force, injection time, and usability, in addition to standard stability, to develop a low-volume Q4W autoinjector. The selected 175 mg/mL formulation delivers an 80 mg dose in 0.46 mL. The viscosity was no more than 10 cP at 15-25{degrees}C and in a 1 mL prefilled syringe, the average glide force was 6 N, and the injection time at a constant force of 20 N was < 2 seconds. The same prefilled syringe was incorporated into an autoinjector with an injection time of less than 2 seconds in air. We conducted a limited assessment of an approved treatment for IgAN (Voyxact) administered via prefilled syringe (PFS) for effects of viscosity, fill volume and syringe configuration under the same experimental conditions. The viscosity at room temperature was 16 cP, with an average glide force of 27N and injection time of 19 seconds for the 2 mL dose. In conclusion, povetacicept was designed to support convenient and user-friendly at-home self-administration through Q4W dosing, a low injection volume, a low viscosity formulation, rapid delivery, and an easy-to-use autoinjector. This integrated formulation and device development approach demonstrates how patient-centric considerations can be incorporated in combination product development. Together, these attributes have the potential to reduce the practical burden associated with repeated, long-term treatment for IgAN patients.
ER  -