Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 12 min ago
Peer-reviewedCC BY-NC-ND 4.0BMC Ophthalmology

Agreement of VCDR measurements: ultra-widefield imaging versus standard fundus photography compared to BMO-OCTA

  1. 1Department of Ophthalmology, The Second Affiliated Hospital of Harbin Medical University, No. 246 Xuefu Road, Nangang District, Harbin, Heilongjiang Province 150086 China

Abstract

Background: This study evaluates the consistency of vertical cup-to-disc ratio (VCDR) measurements using standard fundus photography (Method F) and ultra-widefield (UWF) imaging (Method U), against three-dimensional (3D) Bruch’s membrane opening optical coherence tomography angiography (BMO-OCTA) as an anatomical comparator. Measurement disparities between primary open-angle glaucoma (POAG) and glaucoma suspect (GS) eyes were also assessed.

Methods: This cross-sectional study included 157 eyes (80 POAG, 77 GS) evaluated via standard fundus photography, UWF imaging, and OCTA. VCDR was manually delineated in two-dimensional (2D) images by a masked observer and automatically segmented in BMO-OCTA. Consistency and measurement bias were analyzed using Bland-Altman plots and multivariable Generalized Estimating Equations (GEE) adjusting for patient age to account for inter-eye correlation.

Results: UWF and standard fundus photography were highly correlated (Spearman ρ = 0.951) but exhibited systematic bias (mean bias − 0.024) and wide 95% limits of agreement (-0.112 to 0.065). Compared to the 3D BMO-OCTA, both 2D methods demonstrated a significant overestimation bias. The estimated marginal mean bias of standard fundus photography was significantly lower than that of UWF imaging (0.035 vs. 0.059, Padj < 0.001). 2D measurements demonstrated wider inter-individual measurement dispersion (broader limits of agreement) in GS eyes compared to POAG eyes, reflecting greater measurement variability in this subgroup.

Conclusions: Although UWF imaging correlates well with standard photography, the two modalities are not interchangeable for quantitative optic disc assessment. Both monoscopic 2D modalities systematically overestimate VCDR, exhibiting wider measurement dispersion in GS eyes, a phenomenon potentially related to their atypical optic cup morphology. While 2D imaging remains a fundamental tool for initial screening, relying solely on longitudinal 2D monitoring may introduce clinical uncertainties. To mitigate potential risks associated with the inherent limitations of 2D imaging, we suggest integrating 3D BMO-OCT/OCTA as a complementary structural confirmation tool when a borderline or elevated VCDR is flagged in a glaucoma suspect.

Supplementary Information: The online version contains supplementary material available at https://doi.org/10.1186/s12886-026-05242-5.

Related

  1. AI‐Based Wound Measurement in a Telemedicine‐Style Workflow: Agreement With In‐Person Reference Measurements Compared With Individual Physicians and Expert Consensus
    Tassilo Dege, Vanessa Borst, Luisa Deutzmann +3
    International wound journalPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Extending a Standard SD-OCT Device to Ocular Biometry with Additional Software: Agreement and Clinical Applicability Compared with Ultrasound and Optical Biometry
    İrfan Botan Güneş
    Journal of Clinical MedicinePeer-reviewedCC BY 4.0General medicineCrossref
  3. Using AI-generated ultra-widefield-like fundus images to assist colour fundus photography in screening for chronic kidney disease: a multicentre cross-sectional study
    Renkai Wu, Huiping Yao, Shanshan Wang +12
    BMJ Health & Care InformaticsPeer-reviewedCC BY-NC 4.0Full textMedical imaging & radiologyDOAJPMC
  4. Comparative detection of diabetic retinopathy microvascular lesions using single-capture ultrawide-field swept-source OCT angiography versus widefield colour fundus photography.
    Yusra Asad, Pavan Paniharam, Ser Koon Goh +17
    BMC ophthalmologyPeer-reviewedCC BY-NC-NDFull textGeneral medicineEurope PMC
  5. Amblyopic Eyes Show Reduced Retinal Vessel Density Compared to Fellow Eyes Using Widefield Swept-Source Optical Coherence Tomography Angiography
    Charlotte Egbring, Sarah Kleemann, Nicole Eter +1
    Translational Vision Science & TechnologyPeer-reviewedCC BY 4.0Full textGeneral medicinePMC
BibTeX
@article{li2026agreement,
  title = {{Agreement of VCDR measurements: ultra-widefield imaging versus standard fundus photography compared to BMO-OCTA}},
  author = {Zhongjie Li and Aimeng Dong and Jing Li and Pan Fan and Jinhao Zheng and Xinqi Ye and Wulian Song and Huiping Yuan},
  journal = {BMC Ophthalmology},
  year = {2026},
  month = aug,
  doi = {10.1186/s12886-026-05242-5},
  url = {https://doi.org/10.1186/s12886-026-05242-5},
  note = {CC BY-NC-ND 4.0},
}
RIS
TY  - JOUR
TI  - Agreement of VCDR measurements: ultra-widefield imaging versus standard fundus photography compared to BMO-OCTA
AU  - Zhongjie Li
AU  - Aimeng Dong
AU  - Jing Li
AU  - Pan Fan
AU  - Jinhao Zheng
AU  - Xinqi Ye
AU  - Wulian Song
AU  - Huiping Yuan
PY  - 2026
DA  - 2026/08/19
JO  - BMC Ophthalmology
DO  - 10.1186/s12886-026-05242-5
UR  - https://doi.org/10.1186/s12886-026-05242-5
AB  - Background: This study evaluates the consistency of vertical cup-to-disc ratio (VCDR) measurements using standard fundus photography (Method F) and ultra-widefield (UWF) imaging (Method U), against three-dimensional (3D) Bruch’s membrane opening optical coherence tomography angiography (BMO-OCTA) as an anatomical comparator. Measurement disparities between primary open-angle glaucoma (POAG) and glaucoma suspect (GS) eyes were also assessed.  Methods: This cross-sectional study included 157 eyes (80 POAG, 77 GS) evaluated via standard fundus photography, UWF imaging, and OCTA. VCDR was manually delineated in two-dimensional (2D) images by a masked observer and automatically segmented in BMO-OCTA. Consistency and measurement bias were analyzed using Bland-Altman plots and multivariable Generalized Estimating Equations (GEE) adjusting for patient age to account for inter-eye correlation.  Results: UWF and standard fundus photography were highly correlated (Spearman ρ = 0.951) but exhibited systematic bias (mean bias − 0.024) and wide 95% limits of agreement (-0.112 to 0.065). Compared to the 3D BMO-OCTA, both 2D methods demonstrated a significant overestimation bias. The estimated marginal mean bias of standard fundus photography was significantly lower than that of UWF imaging (0.035 vs. 0.059, Padj < 0.001). 2D measurements demonstrated wider inter-individual measurement dispersion (broader limits of agreement) in GS eyes compared to POAG eyes, reflecting greater measurement variability in this subgroup.  Conclusions: Although UWF imaging correlates well with standard photography, the two modalities are not interchangeable for quantitative optic disc assessment. Both monoscopic 2D modalities systematically overestimate VCDR, exhibiting wider measurement dispersion in GS eyes, a phenomenon potentially related to their atypical optic cup morphology. While 2D imaging remains a fundamental tool for initial screening, relying solely on longitudinal 2D monitoring may introduce clinical uncertainties. To mitigate potential risks associated with the inherent limitations of 2D imaging, we suggest integrating 3D BMO-OCT/OCTA as a complementary structural confirmation tool when a borderline or elevated VCDR is flagged in a glaucoma suspect.  Supplementary Information: The online version contains supplementary material available at https://doi.org/10.1186/s12886-026-05242-5.
SN  - 1471-2415
ER  -