Skip to content
DraconiticResearch
Search Sources API
206,698 studies31 sourcesUpdated 26 min ago
Peer-reviewedCC BY-NC-ND 4.0BMC Surgery

CT-based three-dimensional virtual reduction with implant templating for tibial plateau fractures involving the posterolateral region: a retrospective cohort study of early postoperative CT reduction quality

  1. 1Department of Orthopedics, Affiliated Mindong Hospital, Fujian Medical University, Fujian, China

Abstract

Background: Tibial plateau fractures involving the posterolateral region remain technically challenging because of their deep location, limited surgical exposure, and surrounding anatomical constraints. This study investigated whether CT-based three-dimensional virtual reduction with implant templating was associated with better early postoperative CT reduction quality than conventional CT-based planning.

Methods: This single-center retrospective cohort study included 91 patients surgically treated for tibial plateau fractures involving the posterolateral region between July 2021 and March 2025. Thirty-five patients were planned using CT-based three-dimensional virtual reduction with implant templating, whereas 56 were planned using conventional CT-based planning. The primary outcomes were residual posterolateral articular step-off and gap on CT within 7 days after surgery. Exploratory secondary outcomes included documented planning-to-implementation concordance, perioperative outcomes, early complications, reoperation, 3-month pain and knee flexion range of motion, and 12-month Knee Injury and Osteoarthritis Outcome Score (KOOS) subscale scores. Multivariable linear regression adjusted for prespecified covariates was used to assess the primary outcomes.

Results: The three-dimensional planning group had smaller residual step-off (2.80 [interquartile range, 2.40–3.10] vs. 3.55 [3.00–4.10] mm; P < 0.001) and gap (2.97 ± 0.63 vs. 3.63 ± 0.73 mm; P < 0.001) in the posterolateral quadrant than the conventional planning group. These associations remained after adjustment (step-off: β = −0.75 mm, 95% confidence interval [CI] − 1.08 to − 0.41; gap: β = −0.61 mm, 95% CI − 0.92 to − 0.30; both P < 0.001). Exploratory outcomes showed higher documented fixation-strategy concordance, lower 3-month pain scores, and greater knee flexion ROM in the three-dimensional planning group. No clear between-group differences were observed in surgical-approach concordance, perioperative outcomes, early complications, reoperation, or 12-month KOOS subscale scores.

Conclusions: In this retrospective cohort, CT-based three-dimensional virtual reduction with implant templating was associated with modestly smaller residual posterolateral articular step-off and gap on early postoperative CT than conventional CT-based planning. No clear between-group differences were observed in 12-month KOOS subscale scores, and prospective multicenter validation is needed.

Related

  1. Impact of intertrochanteric bone mineral density on the accuracy of preoperative templating in cementless total hip arthroplasty: a retrospective cohort study of 510 hips.
    Min Uk Do, Kyeong Baek Kim, Sang-Min Lee +3
    BMC musculoskeletal disordersPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMCPMC
  2. Retrospective evaluation of predictors and clinical impact of postoperative delirium in liver transplant recipients
    Chunjiao Long, Huan Lin, Qi-Quan Wan
    MedicinePeer-reviewedCC BY-NCFull textGeneral medicineEurope PMC
  3. Association between anesthetic fresh gas flow and postoperative inflammatory response in laparoscopic sleeve gastrectomy : A retrospective cohort study
    Uğur Serkan Çitilcioğlu, Hatice Kaya Özdoğan
    MedicinePeer-reviewedCC BY-NCFull textGeneral medicineEurope PMC
  4. Effect of intraoperative tranexamic acid use on postoperative bleeding in tumor replacement surgery : A retrospective cohort study
    Bahadır Balkanlı, Abdullah Kahraman, Serkan Bayram +1
    MedicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  5. Postoperative complications and care requirements following Achilles tendon repair : A retrospective cohort study
    Hong Zhao, Jinquan He, Weihong Yu +3
    MedicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{lin2026ctbased,
  title = {{CT-based three-dimensional virtual reduction with implant templating for tibial plateau fractures involving the posterolateral region: a retrospective cohort study of early postoperative CT reduction quality}},
  author = {Jun Lin and Zhenbao Lu and Shuai Zhou and Yinping Lin and Weimin Lin and Weizhong Guo and Shenshen Zhang and Shiqing Lei and Cuihua Yuan and Qilong Huang and Wang Lin},
  journal = {BMC Surgery},
  year = {2026},
  month = aug,
  doi = {10.1186/s12893-026-04113-6},
  url = {https://doi.org/10.1186/s12893-026-04113-6},
  note = {CC BY-NC-ND 4.0},
}
RIS
TY  - JOUR
TI  - CT-based three-dimensional virtual reduction with implant templating for tibial plateau fractures involving the posterolateral region: a retrospective cohort study of early postoperative CT reduction quality
AU  - Jun Lin
AU  - Zhenbao Lu
AU  - Shuai Zhou
AU  - Yinping Lin
AU  - Weimin Lin
AU  - Weizhong Guo
AU  - Shenshen Zhang
AU  - Shiqing Lei
AU  - Cuihua Yuan
AU  - Qilong Huang
AU  - Wang Lin
PY  - 2026
DA  - 2026/08/10
JO  - BMC Surgery
DO  - 10.1186/s12893-026-04113-6
UR  - https://doi.org/10.1186/s12893-026-04113-6
AB  - Background: Tibial plateau fractures involving the posterolateral region remain technically challenging because of their deep location, limited surgical exposure, and surrounding anatomical constraints. This study investigated whether CT-based three-dimensional virtual reduction with implant templating was associated with better early postoperative CT reduction quality than conventional CT-based planning.  Methods: This single-center retrospective cohort study included 91 patients surgically treated for tibial plateau fractures involving the posterolateral region between July 2021 and March 2025. Thirty-five patients were planned using CT-based three-dimensional virtual reduction with implant templating, whereas 56 were planned using conventional CT-based planning. The primary outcomes were residual posterolateral articular step-off and gap on CT within 7 days after surgery. Exploratory secondary outcomes included documented planning-to-implementation concordance, perioperative outcomes, early complications, reoperation, 3-month pain and knee flexion range of motion, and 12-month Knee Injury and Osteoarthritis Outcome Score (KOOS) subscale scores. Multivariable linear regression adjusted for prespecified covariates was used to assess the primary outcomes.  Results: The three-dimensional planning group had smaller residual step-off (2.80 [interquartile range, 2.40–3.10] vs. 3.55 [3.00–4.10] mm; P < 0.001) and gap (2.97 ± 0.63 vs. 3.63 ± 0.73 mm; P < 0.001) in the posterolateral quadrant than the conventional planning group. These associations remained after adjustment (step-off: β = −0.75 mm, 95% confidence interval [CI] − 1.08 to − 0.41; gap: β = −0.61 mm, 95% CI − 0.92 to − 0.30; both P < 0.001). Exploratory outcomes showed higher documented fixation-strategy concordance, lower 3-month pain scores, and greater knee flexion ROM in the three-dimensional planning group. No clear between-group differences were observed in surgical-approach concordance, perioperative outcomes, early complications, reoperation, or 12-month KOOS subscale scores.  Conclusions: In this retrospective cohort, CT-based three-dimensional virtual reduction with implant templating was associated with modestly smaller residual posterolateral articular step-off and gap on early postoperative CT than conventional CT-based planning. No clear between-group differences were observed in 12-month KOOS subscale scores, and prospective multicenter validation is needed.
SN  - 1471-2482
ER  -