Skip to content
DraconiticResearch
Search Sources API
178,033 studies31 sourcesUpdated 39 min ago
PreprintarXiv licencearXiv

1/f frequency noise in mechanical resonators scales inversely with volume, not with quality factor

Abstract

Mechanical frequency-shift sensors have never reached their fundamental thermomechanical or quantum limits. Every material, size, and transduction scheme yet examined yields a 1/f floor 1-3 orders higher, with a flicker-noise coefficient h−1 ∝ 1/Vε. Surveying the published record, I find the invariant h−1 Vε ≡ σA 2 Vε/(2ln 2) independent of device size across 13 decades; volume-independent noise is excluded by 9σ, site-averaging by 3.8σ. No Q dependence appears: reported Q−n laws scale equivalently when Q and volume co-vary; only volume scaling survives when they do not. Mass resolution follows as |δm| ∝ √(h−1 Vε · V).

Related

  1. Role of dissipation dilution in achieving high mechanical quality factors in van der Waals resonators
    Lukas Schleicher, Leonard Geilen, Alexander Musta +5
    arXivPreprintCC BY 4.0Full textCondensed matterQuantum physics & quantum informationarXiv
  2. Phase-Matched Chirps for Energy-Efficient Excitation of Magneto-Mechanical Resonators
    Sarah Reiss, Fabian Mohn, Jonas Faltinath +1
    arXivPreprintarXiv licenceFull textApplied physics & instrumentationarXiv
  3. A Complex‐Frequency Framework for Kerker Unidirectionality in Photonic Resonators
    Loubnan Abou Hamdan, Aloke Jana, Rémi Colom +6
    Laser and Photonics ReviewsPeer-reviewedCC BY-NC-NDFull textAtomic, molecular & optical physicsHAL
  4. Parameter Estimation for Model-Based Sensing of Magneto-Mechanical Resonators
    Sarah Reiss, Tobias Knopp, Justin Ackers +5
    Communications PhysicsPeer-reviewedCC BY 4.0Full textOptics & photonicsCrossref
  5. Enhanced electron-beam lithography to reduce the frequency scatter of 200-400 GHz superconducting microstrip resonators for on-chip filterbank spectrometers
    L. G. G. Olde Scholtenhuis, D. J. Thoen, J. J. A. Baselmans +4
    arXivPreprintCC BY 4.0Full textInstrumentation & methodsApplied physics & instrumentationarXiv
BibTeX
@misc{roukes2026frequency,
  title = {{1/f frequency noise in mechanical resonators scales inversely with volume, not with quality factor}},
  author = {M. L. Roukes},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2609.16668},
  eprint = {2609.16668},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2609.16668},
}
RIS
TY  - UNPB
TI  - 1/f frequency noise in mechanical resonators scales inversely with volume, not with quality factor
AU  - M. L. Roukes
PY  - 2026
DA  - 2026/09/15
PB  - arXiv
DO  - 10.48550/arxiv.2609.16668
UR  - https://arxiv.org/abs/2609.16668
AB  - Mechanical frequency-shift sensors have never reached their fundamental thermomechanical or quantum limits. Every material, size, and transduction scheme yet examined yields a 1/f floor 1-3 orders higher, with a flicker-noise coefficient h_−1 ∝ 1/V_ε. Surveying the published record, I find the invariant h_−1 V_ε ≡ σ_A ^2 V_ε/(2ln 2) independent of device size across 13 decades; volume-independent noise is excluded by 9σ, site-averaging by 3.8σ. No Q dependence appears: reported Q^−n laws scale equivalently when Q and volume co-vary; only volume scaling survives when they do not. Mass resolution follows as |δm| ∝ √(h_−1 V_ε · V).
ER  -