Skip to content
DraconiticResearch
Search Sources API
190,839 studies31 sourcesUpdated 33 min ago
Peer-reviewedCC BYJournal of Analytical Science and Technology

Self-calibrated deadtime correction using poisson-tail invariance in event-driven electron detectors

  1. 1Korea Research Institute of Standards and Science

Abstract

High-flux electron counting with event-driven detectors is fundamentally limited by pixel-level deadtime, resulting in nonlinear count loss, variance suppression, and distortion of spatial intensity profiles. We introduce a monitor-free, self-calibrated deadtime correction method based on the invariance of the long-time Poisson tail of inter-arrival time distributions. Under stationary Poisson illumination, the long-time inter-arrival tail provides an internal statistical estimate of the incident arrival rate, independent of external flux measurements. The approach is demonstrated using high-flux transmission electron microscopy beam-profile measurements, where spatial Fano-factor analysis confirms operation in the deadtime-limited regime. By calibrating an effective extended-deadtime model with the tail-derived rate, the corrected peak count rate increases from approximately 78 kHz to 131 kHz, corresponding to a 67% increase relative to the raw peak. These results establish a self-referenced framework for deadtime correction and dynamic-range extension in event-driven electron detectors, subject to the validity of the stationary-arrival and tail-invariance assumptions.

Related

  1. Correcting basis-set errors due to the absence of the electron-electron cusp using an adiabatic correction
    Anthony Scemama, Andreas Savin
    arXivPreprintarXiv licenceFull textPhysical chemistryarXiv
  2. Physics-Guided Learning with Calibrated Uncertainty for Molecular Thermodynamics Beyond Observed Chemical Space
    Yi-Cheng Shen, Shu Wang, Shiang-Tai Lin
    ChemRxivPreprintLicence not statedGeneral chemistryChemRxiv
  3. Accept or abstain? A pre-specified test of reliability gates calibrated on held-out chemistry for molecular property and reaction-yield models
    Oleksandr Gurbych
    ChemRxivPreprintLicence not statedGeneral chemistryChemRxiv
  4. Molecular Property Prediction with Well-Calibrated Uncertainties via Graph Neural Networks and Conformal Quantile Regression
    Shih-Cheng Li, Charlles R. A. Abreu, Markus Kraft +1
    ChemRxivPreprintCC BYFull textGeneral chemistryChemRxiv
  5. Prioritizing next-day readiness decline in elite female soccer using readiness, workload, and wellness data: A temporally validated and calibrated monitoring framework
    Haojie Long, Longji Li, Lifeng Zhang
    PLOS OnePeer-reviewedCC BY 4.0Full textMaterials & polymersStatisticsPLOS
BibTeX
@article{lee2026selfcalibrated,
  title = {{Self-calibrated deadtime correction using poisson-tail invariance in event-driven electron detectors}},
  author = {Joohyun Lee and Ji-Hwan Kwon and Sooheyong Lee},
  journal = {Journal of Analytical Science and Technology},
  year = {2026},
  month = oct,
  doi = {10.1186/s40543-026-00574-9},
  url = {https://doi.org/10.1186/s40543-026-00574-9},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Self-calibrated deadtime correction using poisson-tail invariance in event-driven electron detectors
AU  - Joohyun Lee
AU  - Ji-Hwan Kwon
AU  - Sooheyong Lee
PY  - 2026
DA  - 2026/10/25
JO  - Journal of Analytical Science and Technology
DO  - 10.1186/s40543-026-00574-9
UR  - https://doi.org/10.1186/s40543-026-00574-9
AB  - High-flux electron counting with event-driven detectors is fundamentally limited by pixel-level deadtime, resulting in nonlinear count loss, variance suppression, and distortion of spatial intensity profiles. We introduce a monitor-free, self-calibrated deadtime correction method based on the invariance of the long-time Poisson tail of inter-arrival time distributions. Under stationary Poisson illumination, the long-time inter-arrival tail provides an internal statistical estimate of the incident arrival rate, independent of external flux measurements. The approach is demonstrated using high-flux transmission electron microscopy beam-profile measurements, where spatial Fano-factor analysis confirms operation in the deadtime-limited regime. By calibrating an effective extended-deadtime model with the tail-derived rate, the corrected peak count rate increases from approximately 78 kHz to 131 kHz, corresponding to a 67% increase relative to the raw peak. These results establish a self-referenced framework for deadtime correction and dynamic-range extension in event-driven electron detectors, subject to the validity of the stationary-arrival and tail-invariance assumptions.
SN  - 2093-3371
ER  -