Skip to content
DraconiticResearch
Search Sources API
201,683 studies31 sourcesUpdated 7 min ago
PreprintCC BY 4.0arXiv

CMS ECAL Phase-2 upgrade: characterisation and stability analysis of a three-stage low-voltage power-conversion system

Abstract

As part of the High-Luminosity upgrade of the Large Hadron Collider, the front-end electronics of the Compact Muon Solenoid electromagnetic calorimeter barrel are being replaced. A three-stage low-voltage power-conversion system supplies the upgraded electronics. As the cascade dynamics require characterisation to ensure stable operation, interactions between the three converter stages are assessed at their two interfaces using the Nyquist criterion. A validated shunt-injection setup using a Bode 100 frequency-response analyser provides in-situ impedance measurements under load to assess the accuracy of the averaged converter models. Results show that both interfaces are stable over the evaluated configurations, with modelled minimum distances to the critical point of 0.76 and 0.79, respectively. A turn-on study identifies capacitor charging at Stage 3 as the main cause of inrush currents triggering Stage 2 overcurrent protection. Two Stage 3 board variants stagger converter enables within and between boards, keeping the measured two-tower current below 5 A, within the 8.0 A protection threshold.

Related

  1. A robust framework for the comprehensive characterisation of parametric down-conversion sources
    Denis A. Kopylov, Michael Stefszky, Christine Silberhorn
    arXivPreprintarXiv licenceFull textOptics & photonicsQuantum physics & quantum informationarXiv
  2. Voltage-embedded equivariant machine learning potential for open system simulations
    Yiming Guan, Rongzhi Gao, ChiYung Yam +2
    arXivPreprintCC BY-NC-ND 4.0Full textPhysical chemistryComputational physicsarXiv
  3. The scintillating fibre beam monitor for the CHNet-MAXI experiment at ISIS: characterisation of the light collection and detection system
    Lisa Malliolio, Riccardo Rossini, Andrea Abba +28
    arXivPreprintCC BY 4.0Full textApplied physics & instrumentationHigh-energy & particle physicsarXiv
  4. Overview of the HL-LHC CMS outer tracker upgrade and lessons learned from 2S module production
    F. Zhang
    arXivPreprintCC BY-NC-ND 4.0Full textHigh-energy & particle physicsarXiv
  5. Evaluating KAGRA upgrade scenarios for multimessenger observations of binary neutron stars
    Yuta Michimura, Soichiro Morisaki, Kenta Hotokezaka +1
    arXivPreprintCC BY 4.0Full textHigh-energy astrophysicsInstrumentation & methodsarXiv
BibTeX
@misc{richter2026ecal,
  title = {{CMS ECAL Phase-2 upgrade: characterisation and stability analysis of a three-stage low-voltage power-conversion system}},
  author = {Liv Anke Richter and Günther Dissertori and Werner Lustermann and Krzysztof Stachon},
  howpublished = {arXiv},
  year = {2026},
  month = nov,
  doi = {10.48550/arxiv.2611.06807},
  eprint = {2611.06807},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2611.06807},
  note = {CC BY 4.0},
}
RIS
TY  - UNPB
TI  - CMS ECAL Phase-2 upgrade: characterisation and stability analysis of a three-stage low-voltage power-conversion system
AU  - Liv Anke Richter
AU  - Günther Dissertori
AU  - Werner Lustermann
AU  - Krzysztof Stachon
PY  - 2026
DA  - 2026/11/04
PB  - arXiv
DO  - 10.48550/arxiv.2611.06807
UR  - https://arxiv.org/abs/2611.06807
AB  - As part of the High-Luminosity upgrade of the Large Hadron Collider, the front-end electronics of the Compact Muon Solenoid electromagnetic calorimeter barrel are being replaced. A three-stage low-voltage power-conversion system supplies the upgraded electronics. As the cascade dynamics require characterisation to ensure stable operation, interactions between the three converter stages are assessed at their two interfaces using the Nyquist criterion. A validated shunt-injection setup using a Bode 100 frequency-response analyser provides in-situ impedance measurements under load to assess the accuracy of the averaged converter models. Results show that both interfaces are stable over the evaluated configurations, with modelled minimum distances to the critical point of 0.76 and 0.79, respectively. A turn-on study identifies capacitor charging at Stage 3 as the main cause of inrush currents triggering Stage 2 overcurrent protection. Two Stage 3 board variants stagger converter enables within and between boards, keeping the measured two-tower current below 5 A, within the 8.0 A protection threshold.
ER  -