A primary study of inverted right-angle configuration cannulated screws fixation of femoral neck fracture based on elaborated 3-dimensional features of the femoral head and neck region

  1. 1Department of Traumatology and Orthopedics, The First Hospital of Dalian Medical University, Dalian, China

Abstract

Background: CT-based three-dimensional (3D) reconstruction was used to analyze the detailed anatomical morphology of the femoral head-neck region, and a modified inverted right-angle cannulated screw configuration was proposed to reduce the risk of posterosuperior screw in-out-in (IOI) placement during femoral neck fracture fixation. Methods: Imaging data from 22 patients (12 males and 10 females; mean age, 52.5 ± 16.8 years) were retrospectively analyzed. CT data of both hips were imported into Mimics to construct 3D digital femoral models for morphologic analysis and screw trajectory simulation. Based on the observed anterior offset of the femoral head-neck canal and the sloped posterosuperior cortex of the femoral neck, a modified inverted right-angle screw configuration and a negative anteversion fluoroscopic view were proposed. Technical feasibility was preliminarily illustrated in two patients with femoral neck fractures. Results: The femoral head-neck axis showed an anterior offset relative to the proximal femoral axis, which may increase the risk of posterosuperior IOI screw trajectory with the traditional inverted triangle configuration. In the 3D simulation, the modified inverted right-angle configuration placed the posterosuperior screw within the proposed safety zone. The negative anteversion fluoroscopic view appeared useful for identifying potential IOI screw trajectory. Technical feasibility of the proposed configuration was illustrated in two patients with femoral neck fractures, in whom no postoperative IOI screw displacement was observed on CT. Conclusion: The anatomical features of the femoral head-neck region may contribute to the risk of posterosuperior IOI screw trajectory with the traditional inverted triangle configuration. In this CT-based morphologic and simulation study, the modified inverted right-angle configuration showed a more favorable simulated position of the posterosuperior screw within the proposed safety zone, while negative anteversion fluoroscopy may help identify potential IOI screw trajectory. These preliminary findings require further validation through biomechanical studies and larger comparative clinical investigations.

Related

  1. Effects of Ultrasound Treatments on the Technological Characteristics of Restructured Cured Cooked Products Elaborated With Pale, Soft and Exudative Pork Loins.
    Amanda Camilo Graciano, Miriam de Andrade Pereira, Larissa Marçal Dos Santos +4
    Journal of food sciencePeer-reviewedCC BYFull textZoology & animal behaviourEurope PMC
  2. Recognition beyond orientation: The processing of facial features for inverted face identification
    Bhavi Bajaj, Joby Joseph
    PsyArXivPreprintAll rights reservedFull textNeuroscienceOSF
  3. Inverted trophic pyramids and transient fish community reorganization in large reservoirs
    A. Sepulveda Correa, K. Turgeon, M. Rodriguez
    bioRxivPreprintCC BYFull textEcologybioRxiv
  4. Preferences for pitch sequence complexity are consistent with an inverted U-shape in humans and parrots
    Oliver T. Bellmann, Marisa Hoeschele, Melina Witt +3
    Royal Society Open SciencePeer-reviewedCC BY 4.0Full textDevelopmental biologyCrossrefEurope PMC
  5. The inverted pyramid of care in modern-day obstetrics
    Laura A. Magee, Peter von Dadelszen, Kypros H. Nicolaides
    PLOS MedicinePeer-reviewedCC BY 4.0Full textDevelopmental biologyEpidemiology & public healthPLOSPMC
BibTeX
@article{liu2026primary,
  title = {{A primary study of inverted right-angle configuration cannulated screws fixation of femoral neck fracture based on elaborated 3-dimensional features of the femoral head and neck region}},
  author = {Changjian Liu and Hanwen Zhang and Yazhou Liu and Peihan Liu and Yang Hou},
  journal = {PLOS One},
  year = {2026},
  month = nov,
  doi = {10.1371/journal.pone.0361871},
  url = {https://doi.org/10.1371/journal.pone.0361871},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - A primary study of inverted right-angle configuration cannulated screws fixation of femoral neck fracture based on elaborated 3-dimensional features of the femoral head and neck region
AU  - Changjian Liu
AU  - Hanwen Zhang
AU  - Yazhou Liu
AU  - Peihan Liu
AU  - Yang Hou
PY  - 2026
DA  - 2026/11/12
JO  - PLOS One
DO  - 10.1371/journal.pone.0361871
UR  - https://doi.org/10.1371/journal.pone.0361871
AB  - Background: CT-based three-dimensional (3D) reconstruction was used to analyze the detailed anatomical morphology of the femoral head-neck region, and a modified inverted right-angle cannulated screw configuration was proposed to reduce the risk of posterosuperior screw in-out-in (IOI) placement during femoral neck fracture fixation. Methods: Imaging data from 22 patients (12 males and 10 females; mean age, 52.5 ± 16.8 years) were retrospectively analyzed. CT data of both hips were imported into Mimics to construct 3D digital femoral models for morphologic analysis and screw trajectory simulation. Based on the observed anterior offset of the femoral head-neck canal and the sloped posterosuperior cortex of the femoral neck, a modified inverted right-angle screw configuration and a negative anteversion fluoroscopic view were proposed. Technical feasibility was preliminarily illustrated in two patients with femoral neck fractures. Results: The femoral head-neck axis showed an anterior offset relative to the proximal femoral axis, which may increase the risk of posterosuperior IOI screw trajectory with the traditional inverted triangle configuration. In the 3D simulation, the modified inverted right-angle configuration placed the posterosuperior screw within the proposed safety zone. The negative anteversion fluoroscopic view appeared useful for identifying potential IOI screw trajectory. Technical feasibility of the proposed configuration was illustrated in two patients with femoral neck fractures, in whom no postoperative IOI screw displacement was observed on CT. Conclusion: The anatomical features of the femoral head-neck region may contribute to the risk of posterosuperior IOI screw trajectory with the traditional inverted triangle configuration. In this CT-based morphologic and simulation study, the modified inverted right-angle configuration showed a more favorable simulated position of the posterosuperior screw within the proposed safety zone, while negative anteversion fluoroscopy may help identify potential IOI screw trajectory. These preliminary findings require further validation through biomechanical studies and larger comparative clinical investigations.
SN  - 1932-6203
ER  -