Synchronized thoracoabdominal and arterial pressure measurement during CPR in fresh-frozen human cadavers
- 1College of Nursing, East Carolina University, 2205W 5th St, Greenville, NC, 27834, USA
- 2Department of Physiology, Brody School of Medicine, East Carolina University, 600 Moye Blvd, Greenville, NC, 27834, USA
- 3Ultrasound and Pain Management, Middle Tennessee School of Anesthesia, 315 Hospital Drive, P.O. Box 417, Madison, TN, 37115, USA
Abstract
Measurement of pressure transmission during cardiopulmonary resuscitation (CPR) is limited in living patients. During cardiac arrest care, the priority is immediate life-saving treatment, making additional invasive monitoring across multiple pressure compartments challenging. Published cadaveric CPR models vary in preparation methods, instrumentation, compression technique, and reporting detail, which limits reproducibility and comparison across studies.
This article describes a fresh-frozen human cadaver method for studying thoracoabdominal pressure transmission during prone and supine mechanical CPR. The method used a within-specimen, counterbalanced crossover design in which two thawed fresh-frozen donors underwent standardized mechanical compressions in prone and supine positions. Synchronized pressure monitoring was used to capture intra-abdominal pressure, intrathoracic pressure, and arterial pressure during each compression cycle. A modified vascular declotting procedure was incorporated with the intention of reducing clot burden and supporting arterial pressure monitoring in thawed fresh-frozen donors.
The methodology focuses on protocolization, invasive instrumentation, compression-trial structure, and reproducible documentation rather than comparative physiologic results. This protocol is intended to make a difficult mechanistic question measurable and support replication in future cadaveric CPR studies.
A within-specimen prone-supine crossover design in human cadavers to study CPR pressure transmission.
Synchronized abdominal, thoracic, and arterial pressure waveforms during compression cycles.
Related
- Thoracoabdominal pressure transmission during prone and supine cardiopulmonary resuscitation in fresh-frozen human cadavers
- Office blood pressure measurement versus ambulatory blood pressure monitoring for detecting undiagnosed hypertension in an apparently healthy Mexican adult cohort: complementary central hemodynamic and arterial stiffness assessment
- Dose–effect relationship of an acute isometric exercise session with different durations on blood pressure and arterial stiffness in prehypertensive substance use disorder individuals
- Luteolin decreases sFlt-1 and mean arterial pressure in the RUPP animal model of placental ischemia
- EphrinA4/EphA4 controls blood pressure via arterial sympathetic innervation in male mice
BibTeX
@article{smith2026synchronized,
title = {{Synchronized thoracoabdominal and arterial pressure measurement during CPR in fresh-frozen human cadavers}},
author = {Zachary Smith and Robert Lust and Christian Falyar and Bimbola F. Akintade and Linda Bolin},
journal = {MethodsX},
year = {2026},
month = oct,
doi = {10.1016/j.mex.2026.104239},
url = {https://doi.org/10.1016/j.mex.2026.104239},
note = {CC BY-NC 4.0},
}
RIS
TY - JOUR
TI - Synchronized thoracoabdominal and arterial pressure measurement during CPR in fresh-frozen human cadavers
AU - Zachary Smith
AU - Robert Lust
AU - Christian Falyar
AU - Bimbola F. Akintade
AU - Linda Bolin
PY - 2026
DA - 2026/10/29
JO - MethodsX
DO - 10.1016/j.mex.2026.104239
UR - https://doi.org/10.1016/j.mex.2026.104239
AB - Measurement of pressure transmission during cardiopulmonary resuscitation (CPR) is limited in living patients. During cardiac arrest care, the priority is immediate life-saving treatment, making additional invasive monitoring across multiple pressure compartments challenging. Published cadaveric CPR models vary in preparation methods, instrumentation, compression technique, and reporting detail, which limits reproducibility and comparison across studies. This article describes a fresh-frozen human cadaver method for studying thoracoabdominal pressure transmission during prone and supine mechanical CPR. The method used a within-specimen, counterbalanced crossover design in which two thawed fresh-frozen donors underwent standardized mechanical compressions in prone and supine positions. Synchronized pressure monitoring was used to capture intra-abdominal pressure, intrathoracic pressure, and arterial pressure during each compression cycle. A modified vascular declotting procedure was incorporated with the intention of reducing clot burden and supporting arterial pressure monitoring in thawed fresh-frozen donors. The methodology focuses on protocolization, invasive instrumentation, compression-trial structure, and reproducible documentation rather than comparative physiologic results. This protocol is intended to make a difficult mechanistic question measurable and support replication in future cadaveric CPR studies. A within-specimen prone-supine crossover design in human cadavers to study CPR pressure transmission. Synchronized abdominal, thoracic, and arterial pressure waveforms during compression cycles.
SN - 2215-0161
ER -