Semi-automatic segmentation of pelvic bone tumors: Usability testing

Abstract

In this study, we focus on studying inter-user variability of a semi-automatic image processing pipeline used for 3D model production and subsequent PSI design in pelvic tumor resection. Six retrospective cases of pelvic bone tumors were segmented. Three different users (trained engineer (TE), orthopedic student (OS), expert orthopedic surgeon (OE)) performed multimodal semi-automatic segmentation on registered CT and MRI sequences. Inter-user variability was evaluated on the tumor models using the symmetrical Hausdorff distances and the DICE similarity coefficient. The mean symmetrical Hausdorff distance was 1.1 mm between TE and OS, 3.8 mm between TE and OE, and 3.6 mm between OS and OE. The mean values for the DICE similarity coefficient were 0.91 between TE and OS, 0.79 between TE and OE, and 0.82 between OS and OE. In patient 5, the DICE coefficient between TE and OE, and OS and OE dropped to 0.18 and 0.24 re-spectively. This study suggests that the inter-user variability between two segmentations of the same tumor cannot be overlooked, especially in complex pelvic tumors: OE expertise seems mandatory for tumor segmentation validation. The collaboration between engineers and clinicians also seems crucial for developing this type of pipeline for patient-specific instruments design purposes.

Related

  1. Segmentation and morphological analysis of recanalized coiled aneurysms: Towards an automatic tool for clipping planning in microsurgery
    Matthieu Coupet, Manel Meftah, Camille Lopez +7
    PLOS OnePeer-reviewedCC BY 4.0Full textNeuroscienceMedical imaging & radiologyPLOS
  2. Automatic bridge crack detections: A lightweight segmentation model for UAV inspection
    Xuwei Dong, Zhibing Yu, Jiashuo Yuan +1
    PLOS OnePeer-reviewedCC BY 4.0Full textNeurosciencePLOS
  3. Automatic Generation of Expert-Level Neuron Segmentation Masks from Fluorescence Microscopy Images for Non-Invasive Deep Learning Analysis of Phase-Contrast Images
    Gerard Villarroya-Piqué, Víctor M. González, Esther Serrano-Pertierra +3
    arXivPreprintCC BY-NC-SA 4.0Full textNeurosciencearXiv
  4. Acceptability and usability of home-based HIV and blood glucose self-testing and home-based blood pressure measurement in Kenya, South Africa, and Zambia
    Carolyn R. Oliver, Meagan J. Bemer, Amber Lauff +10
    PLOS Global Public HealthPeer-reviewedCC BY 4.0Full textMicrobiologyPhysiologyPLOS
  5. Japanese Society for Hereditary Tumors Guidance: Hereditary Cancer Syndromes With Multigene Panel Testing, 2025 Edition.
    Reiko Yoshida, Akira Hirasawa, Issei Imoto +64
    Cancer sciencePeer-reviewedCC BY-NC-NDFull textGenetics & genomicsEurope PMC
BibTeX
@article{vidal2026semiautomatic,
  title = {{Semi-automatic segmentation of pelvic bone tumors: Usability testing}},
  author = {Luciano Vidal and Vincent Biscaccianti and Henri Fragnaud and Jean-Yves Hascoët and Vincent Crenn},
  journal = {Annals of 3D Printed Medicine},
  year = {2026},
  month = aug,
  doi = {10.1016/j.stlm.2022.100098},
  url = {https://nantes-universite.hal.science/hal-04756172v1},
  note = {CC BY-NC-ND 4.0},
}
RIS
TY  - JOUR
TI  - Semi-automatic segmentation of pelvic bone tumors: Usability testing
AU  - Luciano Vidal
AU  - Vincent Biscaccianti
AU  - Henri Fragnaud
AU  - Jean-Yves Hascoët
AU  - Vincent Crenn
PY  - 2026
DA  - 2026/08/31
JO  - Annals of 3D Printed Medicine
DO  - 10.1016/j.stlm.2022.100098
UR  - https://nantes-universite.hal.science/hal-04756172v1
AB  - In this study, we focus on studying inter-user variability of a semi-automatic image processing pipeline used for 3D model production and subsequent PSI design in pelvic tumor resection. Six retrospective cases of pelvic bone tumors were segmented. Three different users (trained engineer (TE), orthopedic student (OS), expert orthopedic surgeon (OE)) performed multimodal semi-automatic segmentation on registered CT and MRI sequences. Inter-user variability was evaluated on the tumor models using the symmetrical Hausdorff distances and the DICE similarity coefficient. The mean symmetrical Hausdorff distance was 1.1 mm between TE and OS, 3.8 mm between TE and OE, and 3.6 mm between OS and OE. The mean values for the DICE similarity coefficient were 0.91 between TE and OS, 0.79 between TE and OE, and 0.82 between OS and OE. In patient 5, the DICE coefficient between TE and OE, and OS and OE dropped to 0.18 and 0.24 re-spectively. This study suggests that the inter-user variability between two segmentations of the same tumor cannot be overlooked, especially in complex pelvic tumors: OE expertise seems mandatory for tumor segmentation validation. The collaboration between engineers and clinicians also seems crucial for developing this type of pipeline for patient-specific instruments design purposes.
SN  - 2666-9641
ER  -