Skip to content
DraconiticResearch
Search Sources API
186,123 studies31 sourcesUpdated 32 min ago
Peer-reviewedCC BYHeliyon

Fluorescence spectroscopy to monitor organic matter transformation during wet air oxidation of membrane-concentrated wastewater

Abstract

Fluorescence spectroscopy was used to monitor organic matter removal during wet air oxidation of four types of membrane-concentrated industrial wastewaters. The overall process performance was assessed through chemical oxygen demand and total organic carbon. Fluorescence intensity exhibited distinct behaviors during wet air oxidation depending on the type of effluent: while some effluents showed a decrease in fluorescence intensities, landfill leachates and dairy wastewaters initially increased before declining. This indicates that heating can break down high-molecular-weight aggregates into smaller, more fluorescent molecules, especially in landfill leachates. The novelty of this study lies in combining fluorescence regional integration with multivariate data analysis to describe and predict global process parameters (chemical oxygen demand and total organic carbon) during wet air oxidation, enabling real-time assessment without using toxic reagents. Principal component analysis revealed that fluorescence responses differentiate samples by temperature and track the transformation of organic matter during oxidation experiments, showing decreases in fulvic and humic acid-like compounds and increases in microbial byproduct-like and aromatic protein-like materials. Partial Least Squares regression models provided satisfactory prediction of total organic carbon and chemical oxygen demand removals based solely on fluorescence intensity.

Related

  1. Fluorescence Correlation Spectroscopy To Study Diffusion and Reaction of Bacteriophages inside Biofilms
    R. Briandet, P. Lacroix-Gueu, M. Renault +6
    Applied and Environmental MicrobiologyPeer-reviewedLicence not stated157 citedEcologyHAL
  2. Feedback to the primary visual cortex is highly concentrated on the central visual field representation
    Piotr Majka, Emmanuel K L Cho, Karolina Łabuszewska +6
    arXivPreprintarXiv licenceFull textNeurosciencearXiv
  3. Inverse covariation between the neocortex and the limbic system is concentrated at deep evolutionary divergences
    B. Wu, N. Imam
    bioRxivPreprintCC BYFull textNeurosciencebioRxiv
  4. Impact of oil composition and dry matter content on the structure and texture of highly concentrated faba bean protein gels
    Alban Fiscarelli, Solange Buchin, Florence Husson +1
    Future FoodsPeer-reviewedCC BY 4.0Full textGeneral biochemistryGeneral biologyHAL
  5. Predictors Recover Most of the Metagenomic Signal for Antibiotic Resistance Gene Occurrence: A Cross-City Test of Geographic Transferability in Urban Wastewater
    S. Falahati Khanaman, B. D. Shrestha Gurung, S. Aryal +3
    bioRxivPreprintAll rights reservedFull textMicrobiologybioRxiv
BibTeX
@article{gout2026fluorescence,
  title = {{Fluorescence spectroscopy to monitor organic matter transformation during wet air oxidation of membrane-concentrated wastewater}},
  author = {Emilie Gout and Fatimatou Toure Lo and Mathias Monnot and Olivier Boutin and Pierre Vanloot and Philippe Moulin},
  journal = {Heliyon},
  year = {2026},
  month = oct,
  doi = {10.1016/j.heliyon.2026.e44989},
  url = {https://hal.science/hal-05828629v1},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Fluorescence spectroscopy to monitor organic matter transformation during wet air oxidation of membrane-concentrated wastewater
AU  - Emilie Gout
AU  - Fatimatou Toure Lo
AU  - Mathias Monnot
AU  - Olivier Boutin
AU  - Pierre Vanloot
AU  - Philippe Moulin
PY  - 2026
DA  - 2026/10/21
JO  - Heliyon
DO  - 10.1016/j.heliyon.2026.e44989
UR  - https://hal.science/hal-05828629v1
AB  - Fluorescence spectroscopy was used to monitor organic matter removal during wet air oxidation of four types of membrane-concentrated industrial wastewaters. The overall process performance was assessed through chemical oxygen demand and total organic carbon. Fluorescence intensity exhibited distinct behaviors during wet air oxidation depending on the type of effluent: while some effluents showed a decrease in fluorescence intensities, landfill leachates and dairy wastewaters initially increased before declining. This indicates that heating can break down high-molecular-weight aggregates into smaller, more fluorescent molecules, especially in landfill leachates. The novelty of this study lies in combining fluorescence regional integration with multivariate data analysis to describe and predict global process parameters (chemical oxygen demand and total organic carbon) during wet air oxidation, enabling real-time assessment without using toxic reagents. Principal component analysis revealed that fluorescence responses differentiate samples by temperature and track the transformation of organic matter during oxidation experiments, showing decreases in fulvic and humic acid-like compounds and increases in microbial byproduct-like and aromatic protein-like materials. Partial Least Squares regression models provided satisfactory prediction of total organic carbon and chemical oxygen demand removals based solely on fluorescence intensity.
SN  - 2405-8440
ER  -