Skip to content
DraconiticResearch
Search Sources API
201,683 studies31 sourcesUpdated 51 min ago
PreprintarXiv licencearXiv

Execution bias, repeatability and mitigation cost in parameter-frozen molecular VQE energy evaluation

Abstract

A smaller statistical error bar need not mean a more accurate molecular energy. We evaluate noiselessly optimized molecular variational quantum eigensolver states on IBM Aachen and Pittsburgh, two 156-qubit Heron processors (provider-reported revision 3). Only energy evaluation runs on hardware, with parameters, layouts and compiled circuits frozen and dynamical decoupling disabled. A five-molecule pilot, three-molecule isolated cohort in three windows and known-state controls comprise 110 jobs and 28.2 billed quantum processing unit (QPU) minutes; the isolated cohort spans 30.2 h within a 31.7 h campaign. Raw 1024 O2 and BeH2 mean residuals exceed returned uncertainty by factors 12-32. Pittsburgh BeH2 cross-job standard deviation is 5.6 times mean returned uncertainty. The zero-noise extrapolation (ZNE) package reduces O2 absolute residuals by 49.7% on Aachen and 83.5% on Pittsburgh at about fourfold charge. On Pittsburgh, twirled readout error extinction (TREX) removes 80 millihartree (mHa) per Raw 1024 job charge versus 50 mHa for ZNE. Controls reveal qubit-124 preparation or readout errors 5.4-5.6 times calibration; 13 mitigated energy point estimates fall outside the mapped spectrum, with no Raw counterpart. These results support workload checks and repeated measurements before additional sampling.

Related

  1. Multi-Parameter Error Mitigation in Parametric Down-Conversion via SU(1, 1) Composite Segmentation
    Nastaran Ragerdi Kashani, Rouhollah Karimzadeh
    arXivPreprintarXiv licenceFull textOptics & photonicsQuantum physics & quantum informationarXiv
  2. When Error Mitigation Makes Things Worse: Budget-Aware Evaluation, Extrapolation Failure, and the Calibration Trust Boundary
    Guilin Zhang, Kai Zhao, Xiquan Cui +3
    arXivPreprintCC BY 4.0Full textQuantum physics & quantum informationarXiv
  3. Molecular-Level Evaluation of the Thermodynamic Properties of Charged Solutions from Submolar to Molar Ion Concentrations
    Sahin Buyukdagli
    arXivPreprintCC BY 4.0Full textCondensed matterarXiv
  4. Repeatability and Cross-Domain Agreement of Pyramidal-Sensor Ocular Wavefront Measurements in Myopic Eyes: A Registry Validation of OSIRIS
    Ivan Gabrić, Ivan Samuel Modrić, Filip Grulović
    Translational Vision Science & TechnologyPeer-reviewedCC BY 4.0Full textOptics & photonicsPMC
  5. Evaluation of upper-scale mechanical parameters of particulate aluminum-based nanocomposites from molecular simulations
    Bartosz Bucholc, Marcin Maździarz, Szymon Nosewicz
    arXivPreprintCC BY 4.0Full textComputational physicsCondensed matterarXiv
BibTeX
@misc{larrucea2026execution,
  title = {{Execution bias, repeatability and mitigation cost in parameter-frozen molecular VQE energy evaluation}},
  author = {Julen Larrucea},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.38885},
  eprint = {2610.38885},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.38885},
}
RIS
TY  - UNPB
TI  - Execution bias, repeatability and mitigation cost in parameter-frozen molecular VQE energy evaluation
AU  - Julen Larrucea
PY  - 2026
DA  - 2026/10/28
PB  - arXiv
DO  - 10.48550/arxiv.2610.38885
UR  - https://arxiv.org/abs/2610.38885
AB  - A smaller statistical error bar need not mean a more accurate molecular energy. We evaluate noiselessly optimized molecular variational quantum eigensolver states on IBM Aachen and Pittsburgh, two 156-qubit Heron processors (provider-reported revision 3). Only energy evaluation runs on hardware, with parameters, layouts and compiled circuits frozen and dynamical decoupling disabled. A five-molecule pilot, three-molecule isolated cohort in three windows and known-state controls comprise 110 jobs and 28.2 billed quantum processing unit (QPU) minutes; the isolated cohort spans 30.2 h within a 31.7 h campaign. Raw 1024 O2 and BeH2 mean residuals exceed returned uncertainty by factors 12-32. Pittsburgh BeH2 cross-job standard deviation is 5.6 times mean returned uncertainty. The zero-noise extrapolation (ZNE) package reduces O2 absolute residuals by 49.7% on Aachen and 83.5% on Pittsburgh at about fourfold charge. On Pittsburgh, twirled readout error extinction (TREX) removes 80 millihartree (mHa) per Raw 1024 job charge versus 50 mHa for ZNE. Controls reveal qubit-124 preparation or readout errors 5.4-5.6 times calibration; 13 mitigated energy point estimates fall outside the mapped spectrum, with no Raw counterpart. These results support workload checks and repeated measurements before additional sampling.
ER  -