Physiology-Informed Blink Artefact Detection from Bilateral Frontal EEG Under Asymmetric Interference
4 affiliations
- 1College of Biomedical Engineering, , Shanghai 200433, China;
- 2Human Phenome Institute, , Shanghai 201203, China (Y.Z.);
- 3Department of Cardiovascular Surgery, Shanghai General Hospital, School of Medicine, Shanghai 200080, China; (J.C.); (F.S.)
- 4Micro-Nano System Centre, School of Information Science and Technology, , Shanghai 200433, China;
Abstract
Eye blinks contaminate frontal electroencephalography (EEG), while asymmetric disturbances can cause false detections. We present a physiology-informed detector that combines waveform correlation, peak-time agreement, amplitude similarity, and symmetric-component dominance in an explicit event-verification rule. It uses two frontal channels without supervised model fitting. Evaluation on raw ZuCo 1.0 recordings included 260 eligible blocks from 12 participants, totalling 1291.61 min and 8611 eye-tracker reference intervals. Scalp and periocular pairs were evaluated separately. On the scalp pair, participant-mean precision was 0.731, recall 0.774, F1 0.734, and false positives 1.469 per minute. At fixed settings, false-positive rates were lower than with single-channel thresholding and bilateral averaging (both Holm-adjusted p = 0.005859), and remained lower than those of four rule-based controls across five perturbation conditions. Threshold-selected simple controls achieved higher precision at similar recall. Component ablations quantified the effects of the verification checks on sensitivity and false positives. The offline Python detector required a median of 2.13 ms per minute of recorded data on an Apple M1 Pro. These results establish a computationally inexpensive approach that makes blink-event decisions directly inspectable through bilateral signal measurements.
Related
- Replacing EEG with peripheral physiological signals for driving behavior recognition: a physiology-informed multimodal approach
- Physiology-Informed Sparse Identification of Dynamic Crop Models
- Physiology-informed high-throughput phenotyping of grain moisture dynamics provides enhanced insights into rice grain weight formation
- Physiology-informed UAV multispectral estimation of tobacco leaf nitrogen nutrition index for variable nitrogen management
- Optimized bilateral segmentation deep learning network for wild animal detection
BibTeX
@article{zhang2026physiologyinformed,
title = {{Physiology-Informed Blink Artefact Detection from Bilateral Frontal EEG Under Asymmetric Interference}},
author = {Weiqiang Zhang and Menglong Li and Yujie Zhang and Jingyi Cao and Feng Shen and Xiaohui Liu and Chen Chen and Yang Li},
journal = {Bioengineering (Basel, Switzerland)},
year = {2026},
month = oct,
doi = {10.3390/bioengineering13101208},
url = {https://europepmc.org/article/PMC/PMC13701908},
note = {CC BY},
}
RIS
TY - JOUR
TI - Physiology-Informed Blink Artefact Detection from Bilateral Frontal EEG Under Asymmetric Interference
AU - Weiqiang Zhang
AU - Menglong Li
AU - Yujie Zhang
AU - Jingyi Cao
AU - Feng Shen
AU - Xiaohui Liu
AU - Chen Chen
AU - Yang Li
PY - 2026
DA - 2026/10/01
JO - Bioengineering (Basel, Switzerland)
DO - 10.3390/bioengineering13101208
UR - https://europepmc.org/article/PMC/PMC13701908
AB - Eye blinks contaminate frontal electroencephalography (EEG), while asymmetric disturbances can cause false detections. We present a physiology-informed detector that combines waveform correlation, peak-time agreement, amplitude similarity, and symmetric-component dominance in an explicit event-verification rule. It uses two frontal channels without supervised model fitting. Evaluation on raw ZuCo 1.0 recordings included 260 eligible blocks from 12 participants, totalling 1291.61 min and 8611 eye-tracker reference intervals. Scalp and periocular pairs were evaluated separately. On the scalp pair, participant-mean precision was 0.731, recall 0.774, F1 0.734, and false positives 1.469 per minute. At fixed settings, false-positive rates were lower than with single-channel thresholding and bilateral averaging (both Holm-adjusted p = 0.005859), and remained lower than those of four rule-based controls across five perturbation conditions. Threshold-selected simple controls achieved higher precision at similar recall. Component ablations quantified the effects of the verification checks on sensitivity and false positives. The offline Python detector required a median of 2.13 ms per minute of recorded data on an Apple M1 Pro. These results establish a computationally inexpensive approach that makes blink-event decisions directly inspectable through bilateral signal measurements.
SN - 2306-5354
ER -