Breakdown of Axis Separability and Structured Inversion in Finite-Domain Normalized Position Measurements: A Quadrant Photodetector Case Study

Abstract

Finite-domain normalized spatial measurements combine an incident field, geometric support, local response, and channel weighting. These operations can break an otherwise separable response, so accurate single-axis calibration alone does not establish separability of a multidimensional measurement. We represent normalized readouts as channel-weight expectations under a parameter-dependent effective measure. For fixed reception and channel operators, local sensitivity is the covariance between the channel weight and the source score. This representation distinguishes axis separability, parameter mixing, and local recoverability, and applies at the appropriate detector level to continuous-electrode position-sensitive detectors, Shack--Hartmann and pyramid wavefront sensors, back-focal-plane split detection, and finite pixel arrays. A quadrant photodetector (QPD) provides an analytically tractable case. Starting from the complete two-dimensional power integrals, we identify the spatial-moment origin of its lowest-order cross term. Axis calibration and system symmetry then constrain the inverse map, giving Axis-Anchored Cross-Residual Inversion (ACRI). Numerical tests of this QPD realization support the sensitivity relations and show that the constrained cross correction substantially reduces the off-axis bias retained by single-axis inversion. The results illustrate how the general measurement representation guides inverse construction, with performance bounded by the working domain, calibration state, and preserved symmetries.

Related

  1. High-Precision Mass Measurements of 52Ni and 51Co Reveal Breakdown of the Isobaric Multiplet Mass Equation in the f p Shell
    F. M. Maier, G. Bollen, B. A. Brown +10
    arXivPreprintCC BY 4.0Full textNuclear physicsarXiv
  2. Machine learning-assisted design and explainable optimization of CdSnP2-based integrated solar-photodetector devices
    Md. Alamin Hossain Pappu, Kazi Abrar Shafin, Mainul Hossain +1
    arXivPreprintarXiv licenceFull textOptics & photonicsarXiv
  3. All-optical 2D perovskite photodetector arrays for pixelated long-wave infrared imaging
    Yanyan Li, Zheng Qian, Du Chen +11
    Light: Science & ApplicationsPeer-reviewedCC BY 4.0Full textOptics & photonicsCrossrefEurope PMCPMC
  4. Compact Variational Neural Networks for Spectral Inference from a Single Nonlinear 2D Perovskite Photodetector
    Karl Jonas Riisnaes, Ned Thaddeus Taylor, Hoi Tung Lam +4
    arXivPreprintarXiv licenceFull textApplied physics & instrumentationCondensed matterarXiv
  5. Separability from Multipartite Measures
    Chen-Te Ma, Ma-Ke Yuan
    arXivPreprintarXiv licenceFull textMathematical physicsHigh-energy & particle physicsarXiv
BibTeX
@misc{su2026breakdown,
  title = {{Breakdown of Axis Separability and Structured Inversion in Finite-Domain Normalized Position Measurements: A Quadrant Photodetector Case Study}},
  author = {Zhiqian Su},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2609.29009},
  eprint = {2609.29009},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2609.29009},
}
RIS
TY  - UNPB
TI  - Breakdown of Axis Separability and Structured Inversion in Finite-Domain Normalized Position Measurements: A Quadrant Photodetector Case Study
AU  - Zhiqian Su
PY  - 2026
DA  - 2026/09/24
PB  - arXiv
DO  - 10.48550/arxiv.2609.29009
UR  - https://arxiv.org/abs/2609.29009
AB  - Finite-domain normalized spatial measurements combine an incident field, geometric support, local response, and channel weighting. These operations can break an otherwise separable response, so accurate single-axis calibration alone does not establish separability of a multidimensional measurement. We represent normalized readouts as channel-weight expectations under a parameter-dependent effective measure. For fixed reception and channel operators, local sensitivity is the covariance between the channel weight and the source score. This representation distinguishes axis separability, parameter mixing, and local recoverability, and applies at the appropriate detector level to continuous-electrode position-sensitive detectors, Shack--Hartmann and pyramid wavefront sensors, back-focal-plane split detection, and finite pixel arrays. A quadrant photodetector (QPD) provides an analytically tractable case. Starting from the complete two-dimensional power integrals, we identify the spatial-moment origin of its lowest-order cross term. Axis calibration and system symmetry then constrain the inverse map, giving Axis-Anchored Cross-Residual Inversion (ACRI). Numerical tests of this QPD realization support the sensitivity relations and show that the constrained cross correction substantially reduces the off-axis bias retained by single-axis inversion. The results illustrate how the general measurement representation guides inverse construction, with performance bounded by the working domain, calibration state, and preserved symmetries.
ER  -