Skip to content
DraconiticResearch
Search Sources API
203,234 studies31 sourcesUpdated 1 h ago
Peer-reviewedCC BYNMR in biomedicine

Radial Tiny Golden Angle UTE (tyGA-UTE) for Cardiac MRI in the Small Animal Model.

5 affiliations
  1. 1Department of Cardiology, the First Affiliated Hospital of Shandong First Medical University & Shandong Provincial Qianfoshan Hospital, Jinan, China.
  2. 2Center for Medical Artificial Intelligence, Shandong University of Traditional Chinese Medicine, Qingdao, Shandong, China.
  3. 3Department of Internal Medicine II, Ulm University Medical Center, Ulm, Germany.
  4. 4Department of Radiology, the First Affiliated Hospital of Shandong First Medical University & Shandong Provincial Qianfoshan Hospital, Jinan, China.
  5. 5Ulm University, Core Facility Small Animal Imaging, Ulm, Germany.

Abstract

Robust cardiorespiratory motion correction is critical for high-quality ultra-high-field (UHF) preclinical cardiac magnetic resonance imaging (MRI). Whereas radial tiny golden angle (tyGA) sampling, data-driven self-gating (sg), compressed sensing (CS), and ultrashort echo time (UTE) are individually well-established techniques, their integration into a unified acquisition and reconstruction pipeline, together with systematic validation at 11.7 T remains insufficiently explored. This study presents and validates a UHF-optimized tyGA-based UTE workflow that enables high-temporal-resolution sliding-window dynamic imaging (SW-tyGA-UTE) and high-spatial-resolution cardiorespiratory self-gated cine imaging (Gated-tyGA-UTE) from a single continuous acquired tyGA acquisition. All experiments were performed on an 11.7-T small-animal MRI system in 16 healthy wild-type mice. Cardiac functional parameters, image quality metrics (signal-to-noise ratio [SNR] and contrast-to-noise ratio [CNR]), and inter-/intra-observer reproducibility were systematically compared between the proposed tyGA-UTE pipeline and two navigator-gated reference techniques: retrospectively gated FLASH and UTE methodologies. SW-tyGA-UTE and Gated-tyGA-UTE reconstructions yielded global left ventricular functional parameters comparable to those obtained with the reference methods (all p > 0.05). All functional metrics showed excellent intra-observer (ICC = 0.94-0.99) and inter-observer (ICC = 0.90-0.98) reproducibility, with ejection fraction showing the highest measurement consistency. Image quality was evaluated using an image-based within-ROI noise quantification approach that captures both thermal noise and reconstruction-related artifacts. In this analysis, the Gated-tyGA-UTE protocol showed no statistically significant differences in left ventricular blood-pool SNR, myocardial SNR, or CNR relative to the reference sequences. In contrast, the high-temporal-resolution sliding-window reconstruction showed significantly reduced image quality across all three metrics, consistent with the expected spatiotemporal trade-off of undersampled dynamic imaging. This study validates a robust, UHF-optimized tyGA-UTE imaging workflow that generates both high-fidelity quantitative cine data and ultra-fast dynamic cardiac images from a single acquisition. The unified pipeline eliminates the need for sequential repeated scans, minimizes anesthesia-related physiological variability, and improves experimental efficiency, providing a practical tool for preclinical cardiac phenotyping, longitudinal studies, and drug screening.

Related

  1. Quantitative Chemical Exchange Saturation Transfer Imaging With Golden-Angle Radial k-Space Sampling and Locally Low-Rank Reconstruction.
    Ouri Cohen, Elizabeth J Sutton, Robert J Young +1
    NMR in biomedicinePeer-reviewedCC BY-NC-NDFull textMedical imaging & radiologyEurope PMC
  2. Effects of N-Acetylcysteine and Glycine Administration on Serum Levels of Soluble Suppressor of Tumorigenicity 2 and Cardiac Morphological Characteristics in an Animal Model of Streptozotocin-Induced Diabetes.
    Malik Ejubović, Radivoj Jadrić, Sabaheta Hasić +7
    Pathophysiology : the official journal of the International Society for PathophysiologyPeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
  3. Mucosal protrusion angle measured on capsule endoscopy for the diagnosis of small bowel submucosal tumors: a preliminary exploration of diagnostic accuracy based on a case series
    Zhaoguo Xue, Yongming Kang, Xiaomei Sun
    Videosurgery and other Miniinvasive TechniquesPeer-reviewedCC BY-NC-SA 4.0Full textSurgery & anaesthesiaPMC
  4. Bioelectrical Impedance Analysis–Derived Phase Angle in Initial Medical and Nursing Assessment for Cardiac Rehabilitation: Association with Cardiac Rehabilitation Risk Category and Longitudinal Change During the Program—An Exploratory Prospective Observational Study
    Francisco José Rodríguez-Velasco, José Alberto Becerra-Mejías, Luis Miguel Lara-Godoy +3
    Journal of Clinical MedicinePeer-reviewedCC BY 4.0General medicineCrossref
  5. Combined Accommodation and Fusional Training Paradigm Versus Prism Correction for Small-Angle Acute Acquired Comitant Esotropia: A Cohort Study
    Shuyang Guo, Ling Ling, Ziqing Ding +7
    Ophthalmology and TherapyPeer-reviewedCC BY-NCFull textGeneral medicineDOAJ
BibTeX
@article{li2026radial,
  title = {{Radial Tiny Golden Angle UTE (tyGA-UTE) for Cardiac MRI in the Small Animal Model.}},
  author = {Hao Li and Patrick Metze and Pengxi Han and Benzheng Wei and Volker Rasche},
  journal = {NMR in biomedicine},
  year = {2026},
  month = oct,
  doi = {10.1002/nbm.70418},
  url = {https://europepmc.org/article/MED/42875891},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Radial Tiny Golden Angle UTE (tyGA-UTE) for Cardiac MRI in the Small Animal Model.
AU  - Hao Li
AU  - Patrick Metze
AU  - Pengxi Han
AU  - Benzheng Wei
AU  - Volker Rasche
PY  - 2026
DA  - 2026/10/30
JO  - NMR in biomedicine
DO  - 10.1002/nbm.70418
UR  - https://europepmc.org/article/MED/42875891
AB  - Robust cardiorespiratory motion correction is critical for high-quality ultra-high-field (UHF) preclinical cardiac magnetic resonance imaging (MRI). Whereas radial tiny golden angle (tyGA) sampling, data-driven self-gating (sg), compressed sensing (CS), and ultrashort echo time (UTE) are individually well-established techniques, their integration into a unified acquisition and reconstruction pipeline, together with systematic validation at 11.7 T remains insufficiently explored. This study presents and validates a UHF-optimized tyGA-based UTE workflow that enables high-temporal-resolution sliding-window dynamic imaging (SW-tyGA-UTE) and high-spatial-resolution cardiorespiratory self-gated cine imaging (Gated-tyGA-UTE) from a single continuous acquired tyGA acquisition. All experiments were performed on an 11.7-T small-animal MRI system in 16 healthy wild-type mice. Cardiac functional parameters, image quality metrics (signal-to-noise ratio [SNR] and contrast-to-noise ratio [CNR]), and inter-/intra-observer reproducibility were systematically compared between the proposed tyGA-UTE pipeline and two navigator-gated reference techniques: retrospectively gated FLASH and UTE methodologies. SW-tyGA-UTE and Gated-tyGA-UTE reconstructions yielded global left ventricular functional parameters comparable to those obtained with the reference methods (all p > 0.05). All functional metrics showed excellent intra-observer (ICC = 0.94-0.99) and inter-observer (ICC = 0.90-0.98) reproducibility, with ejection fraction showing the highest measurement consistency. Image quality was evaluated using an image-based within-ROI noise quantification approach that captures both thermal noise and reconstruction-related artifacts. In this analysis, the Gated-tyGA-UTE protocol showed no statistically significant differences in left ventricular blood-pool SNR, myocardial SNR, or CNR relative to the reference sequences. In contrast, the high-temporal-resolution sliding-window reconstruction showed significantly reduced image quality across all three metrics, consistent with the expected spatiotemporal trade-off of undersampled dynamic imaging. This study validates a robust, UHF-optimized tyGA-UTE imaging workflow that generates both high-fidelity quantitative cine data and ultra-fast dynamic cardiac images from a single acquisition. The unified pipeline eliminates the need for sequential repeated scans, minimizes anesthesia-related physiological variability, and improves experimental efficiency, providing a practical tool for preclinical cardiac phenotyping, longitudinal studies, and drug screening.
SN  - 0952-3480
SN  - 1099-1492
ER  -