Microcirculation Mirror: A zero-install browser workstation for hand microvascular anatomy and nailfold capillaroscopy
- 1Chinese Academy of Medical Sciences & Peking Union Medical College
Abstract
Background Hand microvasculature is conventionally presented through diagrams, cadaveric atlases and specialized optical instruments, while conventional clinical radiography cannot resolve individual capillary loops (5-15 m lumen) in vivo, which dominate cutaneous oxygen exchange. Methods We present Microcirculation Mirror, a zero-install browser workstation that registers layered hand anatomy to a live 21-landmark pose and couples it to a nailfold video capillaroscopy (NVC) simulator, a lumped microcirculatory model and an imaging-physics module. The single-file application runs offline on a laptop or, over local HTTPS, on a phone as an installable app. Results Its 3D atlas contains 136 named structures per hand in six systems from open Z-Anatomy/BodyParts3D meshes, plus a literature-parameterized capillary layer. The NVC module renders a 200x, 1.2-mm field with six deterministic patterns and quantified density, giant capillaries, avascular width fraction, hemorrhages, tortuosity and ramification. A lumped model reports nine estimates (SIM); a physics module shows that a 10-m capillary occupies 0.07 of a 150-m detector pixel; with iodinated contrast it retains {approx}0.016% effective contrast, about 60x below a 1% detection threshold; unenhanced blood is {approx}270x lower. The 2D stage renders in 2.9 ms per frame; system merging reduces atlas draw calls from 136 to 6. Conclusions The camera-overlay layers are templates, the atlas macro-anatomy is open mesh data, and the capillary layer is sampled. No patient data are used. The instrument is a product prototype, not a medical device, and provides a reproducible framework for making multi-scale microvascular reasoning visible.
Related
- Persistent intercritical microvascular abnormalities in primary erythromelalgia: a quantitative nailfold capillaroscopy observation؆
- Sotatercept-related peripheral microvascular alterations in systemic sclerosis–associated pulmonary arterial hypertension: insights from nailfold capillaroscopy
- Assessment of nailfold microcirculation in non-dialysis CKD: Capillaroscopic indicators correlated with renal dysfunction
- OP–109 Nailfold videocapillaroscopy practices among pediatric rheumatologists in türkiye: a national survey
- Simulation-based detection of usability conflicts for an ISO/IEEE 11073 SDC workstation: a spine surgery case study
BibTeX
@misc{wang2026microcirculation,
title = {{Microcirculation Mirror: A zero-install browser workstation for hand microvascular anatomy and nailfold capillaroscopy}},
author = {Y. Wang and J. He and W. Liu and X. Xu and B. Li and Y. Li and B. Wang and M. Liu},
howpublished = {medRxiv},
year = {2026},
month = nov,
doi = {10.64898/2026.11.15.26368085},
url = {https://www.medrxiv.org/content/10.64898/2026.11.15.26368085v1},
note = {CC BY-NC},
}
RIS
TY - UNPB
TI - Microcirculation Mirror: A zero-install browser workstation for hand microvascular anatomy and nailfold capillaroscopy
AU - Y. Wang
AU - J. He
AU - W. Liu
AU - X. Xu
AU - B. Li
AU - Y. Li
AU - B. Wang
AU - M. Liu
PY - 2026
DA - 2026/11/15
PB - medRxiv
DO - 10.64898/2026.11.15.26368085
UR - https://www.medrxiv.org/content/10.64898/2026.11.15.26368085v1
AB - Background Hand microvasculature is conventionally presented through diagrams, cadaveric atlases and specialized optical instruments, while conventional clinical radiography cannot resolve individual capillary loops (5-15 m lumen) in vivo, which dominate cutaneous oxygen exchange. Methods We present Microcirculation Mirror, a zero-install browser workstation that registers layered hand anatomy to a live 21-landmark pose and couples it to a nailfold video capillaroscopy (NVC) simulator, a lumped microcirculatory model and an imaging-physics module. The single-file application runs offline on a laptop or, over local HTTPS, on a phone as an installable app. Results Its 3D atlas contains 136 named structures per hand in six systems from open Z-Anatomy/BodyParts3D meshes, plus a literature-parameterized capillary layer. The NVC module renders a 200x, 1.2-mm field with six deterministic patterns and quantified density, giant capillaries, avascular width fraction, hemorrhages, tortuosity and ramification. A lumped model reports nine estimates (SIM); a physics module shows that a 10-m capillary occupies 0.07 of a 150-m detector pixel; with iodinated contrast it retains {approx}0.016% effective contrast, about 60x below a 1% detection threshold; unenhanced blood is {approx}270x lower. The 2D stage renders in 2.9 ms per frame; system merging reduces atlas draw calls from 136 to 6. Conclusions The camera-overlay layers are templates, the atlas macro-anatomy is open mesh data, and the capillary layer is sampled. No patient data are used. The instrument is a product prototype, not a medical device, and provides a reproducible framework for making multi-scale microvascular reasoning visible.
ER -