Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 28 min ago
PreprintCC BY-NCmedRxiv

Microcirculation Mirror: A zero-install browser workstation for hand microvascular anatomy and nailfold capillaroscopy

  1. 1Chinese Academy of Medical Sciences & Peking Union Medical College

Abstract

Background Hand microvasculature is conventionally presented through diagrams, cadaveric atlases and specialized optical instruments, while conventional clinical radiography cannot resolve individual capillary loops (5-15 m lumen) in vivo, which dominate cutaneous oxygen exchange. Methods We present Microcirculation Mirror, a zero-install browser workstation that registers layered hand anatomy to a live 21-landmark pose and couples it to a nailfold video capillaroscopy (NVC) simulator, a lumped microcirculatory model and an imaging-physics module. The single-file application runs offline on a laptop or, over local HTTPS, on a phone as an installable app. Results Its 3D atlas contains 136 named structures per hand in six systems from open Z-Anatomy/BodyParts3D meshes, plus a literature-parameterized capillary layer. The NVC module renders a 200x, 1.2-mm field with six deterministic patterns and quantified density, giant capillaries, avascular width fraction, hemorrhages, tortuosity and ramification. A lumped model reports nine estimates (SIM); a physics module shows that a 10-m capillary occupies 0.07 of a 150-m detector pixel; with iodinated contrast it retains {approx}0.016% effective contrast, about 60x below a 1% detection threshold; unenhanced blood is {approx}270x lower. The 2D stage renders in 2.9 ms per frame; system merging reduces atlas draw calls from 136 to 6. Conclusions The camera-overlay layers are templates, the atlas macro-anatomy is open mesh data, and the capillary layer is sampled. No patient data are used. The instrument is a product prototype, not a medical device, and provides a reproducible framework for making multi-scale microvascular reasoning visible.

Related

  1. Persistent intercritical microvascular abnormalities in primary erythromelalgia: a quantitative nailfold capillaroscopy observation؆
    Angelo Nigro
    Anais Brasileiros de DermatologiaPeer-reviewedCC BY 4.0Full textGeneral medicinePMC
  2. Sotatercept-related peripheral microvascular alterations in systemic sclerosis–associated pulmonary arterial hypertension: insights from nailfold capillaroscopy
    Yuichiro Segawa, Takehiro Takahashi, Jun Yamamoto +12
    Rheumatology Advances in PracticePeer-reviewedCC BY 4.0Full textGeneral medicinePMCEurope PMC
  3. Assessment of nailfold microcirculation in non-dialysis CKD: Capillaroscopic indicators correlated with renal dysfunction
    Shulin Li, Ying Liu, Han Yan +5
    PLOS OnePeer-reviewedCC BY 4.0Full textPhysiologyPLOS
  4. OP–109 Nailfold videocapillaroscopy practices among pediatric rheumatologists in türkiye: a national survey
    Figen Çakmak, Nuray Aktay Ayaz, Zeynep Hazıroğlu Ökmen +4
    BMJ Paediatrics OpenPeer-reviewedCC BYObstetrics, gynaecology & paediatricsDOAJ
  5. Simulation-based detection of usability conflicts for an ISO/IEEE 11073 SDC workstation: a spine surgery case study
    Okan Yilmaz, Simon Kißmann, Rastislav Pjontek +4
    International Journal of Computer Assisted Radiology and SurgeryPeer-reviewedCC BY 4.0Full textSurgery & anaesthesiaPMC
BibTeX
@misc{wang2026microcirculation,
  title = {{Microcirculation Mirror: A zero-install browser workstation for hand microvascular anatomy and nailfold capillaroscopy}},
  author = {Y. Wang and J. He and W. Liu and X. Xu and B. Li and Y. Li and B. Wang and M. Liu},
  howpublished = {medRxiv},
  year = {2026},
  month = nov,
  doi = {10.64898/2026.11.15.26368085},
  url = {https://www.medrxiv.org/content/10.64898/2026.11.15.26368085v1},
  note = {CC BY-NC},
}
RIS
TY  - UNPB
TI  - Microcirculation Mirror: A zero-install browser workstation for hand microvascular anatomy and nailfold capillaroscopy
AU  - Y. Wang
AU  - J. He
AU  - W. Liu
AU  - X. Xu
AU  - B. Li
AU  - Y. Li
AU  - B. Wang
AU  - M. Liu
PY  - 2026
DA  - 2026/11/15
PB  - medRxiv
DO  - 10.64898/2026.11.15.26368085
UR  - https://www.medrxiv.org/content/10.64898/2026.11.15.26368085v1
AB  - Background Hand microvasculature is conventionally presented through diagrams, cadaveric atlases and specialized optical instruments, while conventional clinical radiography cannot resolve individual capillary loops (5-15 m lumen) in vivo, which dominate cutaneous oxygen exchange. Methods We present Microcirculation Mirror, a zero-install browser workstation that registers layered hand anatomy to a live 21-landmark pose and couples it to a nailfold video capillaroscopy (NVC) simulator, a lumped microcirculatory model and an imaging-physics module. The single-file application runs offline on a laptop or, over local HTTPS, on a phone as an installable app. Results Its 3D atlas contains 136 named structures per hand in six systems from open Z-Anatomy/BodyParts3D meshes, plus a literature-parameterized capillary layer. The NVC module renders a 200x, 1.2-mm field with six deterministic patterns and quantified density, giant capillaries, avascular width fraction, hemorrhages, tortuosity and ramification. A lumped model reports nine estimates (SIM); a physics module shows that a 10-m capillary occupies 0.07 of a 150-m detector pixel; with iodinated contrast it retains {approx}0.016% effective contrast, about 60x below a 1% detection threshold; unenhanced blood is {approx}270x lower. The 2D stage renders in 2.9 ms per frame; system merging reduces atlas draw calls from 136 to 6. Conclusions The camera-overlay layers are templates, the atlas macro-anatomy is open mesh data, and the capillary layer is sampled. No patient data are used. The instrument is a product prototype, not a medical device, and provides a reproducible framework for making multi-scale microvascular reasoning visible.
ER  -