Model predictive control for intelligent PID self-tuning in HVAC systems achieves adaptable energy savings in ultra-low energy buildings

  1. 1School of Civil Engineering, Zhengzhou University
  2. 2Faculty of Engineering and Architectural Science, Toronto Metropolitan University
  3. 3Fivewin Architecture Technology Group

Abstract

In ultra-low energy buildings, maintaining the HVAC efficiency under dynamic operating conditions remains a critical challenge, particularly for conventional proportional-integral-derivative (PID) controllers with fixed parameters, which lack the adaptability to handle system nonlinearities and variable meteorological loads. To address this, this study develops and comparatively evaluates two model predictive control (MPC)-oriented strategies, namely neural network‑based and fuzzy‑logic‑based (denoted as NN‑MPC and FLC‑MPC for brevity), for the real-time PID self-tuning in a ground-source heat pump system in an ultra-low energy building. The core innovation lies in the FLC-MPC’s rule-based architecture, which excels in adapting to system nonlinearities and operational uncertainties over conventional data-driven approaches. Simulation results obtained from a calibrated TRNSYS model reveal that, the main contribution is a direct and quantitative demonstration of this adaptability, for which the NN-MPC achieves a mean saving of 1.72% over the two test days, whereas the FLC-MPC delivers a greater average saving of 5.55% with a peak of 16.46% on the tested day of August 10, while maintaining the indoor temperature at the fixed comfort setpoints specified in the simulation. Beyond this, the proposed data-driven MPC framework offers significant application potential, by being integrated into existing Building Management Systems, enabling the data-informed PID parameter tuning without hardware replacement. This facilitates the self-adaptive HVAC control that effectively balances energy efficiency and thermal comfort under diverse meteorological conditions, suggesting its potential applicability for next-generation low-energy building operations.

Related

  1. Predictive multi-energy management and optimization of renewable-integrated smart buildings with coupled electrical–thermal loads and hybrid energy storage
    B. Prasanth, G. Karthikeyan, Asaba Shabiluh
    Scientific ReportsPeer-reviewedCC BYFull textGeneral medicineDOAJ
  2. Intelligent UPQC control using SA-GANN and optimized DC-link regulation in grid-connected microgrids
    D. Anitha, K. Premkumar
    Scientific ReportsPeer-reviewedCC BYFull textGeneral medicineDOAJ
  3. Intelligent power flow control of AC/DC hybrid transmission corridors using safe reinforcement learning agents
    Haifeng Li, Zhiwei Wang, Tao Jin +1
    Scientific ReportsPeer-reviewedCC BYFull textGeneral medicineDOAJ
  4. An intelligent internet of things-based artificial intelligence framework for adaptive mechanical process control and real-time performance optimization
    Vijaya Bhaskar Sadu, Gopala Rao L. V. V., Gopala Krishna A
    Scientific ReportsPeer-reviewedCC BYFull textGeneral medicineDOAJ
  5. Tail-Risk-Aware Model Predictive Control for Hypoglycemia Mitigation in Automated Insulin Delivery
    Kaiyuan Zhang, Congyu Han, Hexing Guo +5
    MetabolitesPeer-reviewedCC BY 4.0Full textEndocrinology & metabolismCrossrefEurope PMC
BibTeX
@article{chen2026model,
  title = {{Model predictive control for intelligent PID self-tuning in HVAC systems achieves adaptable energy savings in ultra-low energy buildings}},
  author = {Yibo Chen and Xin Fang and Umberto Berardi and Xu Chen and Guoyou Cui and Jianzhong Yang},
  journal = {Scientific Reports},
  year = {2026},
  month = sep,
  doi = {10.1038/s41598-026-69713-x},
  url = {https://doi.org/10.1038/s41598-026-69713-x},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Model predictive control for intelligent PID self-tuning in HVAC systems achieves adaptable energy savings in ultra-low energy buildings
AU  - Yibo Chen
AU  - Xin Fang
AU  - Umberto Berardi
AU  - Xu Chen
AU  - Guoyou Cui
AU  - Jianzhong Yang
PY  - 2026
DA  - 2026/09/01
JO  - Scientific Reports
DO  - 10.1038/s41598-026-69713-x
UR  - https://doi.org/10.1038/s41598-026-69713-x
AB  - In ultra-low energy buildings, maintaining the HVAC efficiency under dynamic operating conditions remains a critical challenge, particularly for conventional proportional-integral-derivative (PID) controllers with fixed parameters, which lack the adaptability to handle system nonlinearities and variable meteorological loads. To address this, this study develops and comparatively evaluates two model predictive control (MPC)-oriented strategies, namely neural network‑based and fuzzy‑logic‑based (denoted as NN‑MPC and FLC‑MPC for brevity), for the real-time PID self-tuning in a ground-source heat pump system in an ultra-low energy building. The core innovation lies in the FLC-MPC’s rule-based architecture, which excels in adapting to system nonlinearities and operational uncertainties over conventional data-driven approaches. Simulation results obtained from a calibrated TRNSYS model reveal that, the main contribution is a direct and quantitative demonstration of this adaptability, for which the NN-MPC achieves a mean saving of 1.72% over the two test days, whereas the FLC-MPC delivers a greater average saving of 5.55% with a peak of 16.46% on the tested day of August 10, while maintaining the indoor temperature at the fixed comfort setpoints specified in the simulation. Beyond this, the proposed data-driven MPC framework offers significant application potential, by being integrated into existing Building Management Systems, enabling the data-informed PID parameter tuning without hardware replacement. This facilitates the self-adaptive HVAC control that effectively balances energy efficiency and thermal comfort under diverse meteorological conditions, suggesting its potential applicability for next-generation low-energy building operations.
SN  - 2045-2322
ER  -