PreprintCC BY-NC-ND 4.0arXiv
BOLD PSF: Impact of k-space trajectories and timing on the depiction of T2* contrast
Abstract
The timing of BOLD-fMRI is typically chosen such that TE matches T2*. This assumes contrast being exclusively elicited by signal differences at TE. While sensible for short or TE-symmetric readouts, such as EPIs, it oversimplifies contrast generation for longer or TE-asymmetric trajectories, such as spirals. We propose the concept of a BOLD PSF for a more comprehensive perspective on the imaging characteristics of a functional experiment. Our findings indicate that TE can be reduced for spiral-out without sacrificing BOLD-sensitivity when compared to EPI. Furthermore, we characterize the intrinsic trade-off between specificity and resolution of the BOLD response under varying TE.
Related
- Impact of segmented deformable mirrors on high-contrast testbeds for exoplanet imaging with future large space telescopes: contrast stability assessment on the HiCAT bench
- Two-stage cooperative optimisation of signal timing and vehicle trajectories for eco-driving at signalised intersections under HDV/CAV/CCAV mixed traffic
- Impact of light shift inhomogeneities on the contrast of light pulse atom interferometers
- Exploring and optimizing the Vivado Flow on large FPGA designs: A Practical Analysis of Strategies and Their Impact on Timing
- Thermodynamics of the space of trajectories governed by a combination of two additive boundary functionals
BibTeX
@misc{engel2026bold,
title = {{BOLD PSF: Impact of k-space trajectories and timing on the depiction of T2* contrast}},
author = {Maria Engel and Lars Kasper and Klaas P Pruessmann},
howpublished = {arXiv},
year = {2026},
month = oct,
doi = {10.48550/arxiv.2610.15524},
eprint = {2610.15524},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2610.15524},
note = {CC BY-NC-ND 4.0},
}
RIS
TY - UNPB
TI - BOLD PSF: Impact of k-space trajectories and timing on the depiction of T2* contrast
AU - Maria Engel
AU - Lars Kasper
AU - Klaas P Pruessmann
PY - 2026
DA - 2026/10/11
PB - arXiv
DO - 10.48550/arxiv.2610.15524
UR - https://arxiv.org/abs/2610.15524
AB - The timing of BOLD-fMRI is typically chosen such that TE matches T2*. This assumes contrast being exclusively elicited by signal differences at TE. While sensible for short or TE-symmetric readouts, such as EPIs, it oversimplifies contrast generation for longer or TE-asymmetric trajectories, such as spirals. We propose the concept of a BOLD PSF for a more comprehensive perspective on the imaging characteristics of a functional experiment. Our findings indicate that TE can be reduced for spiral-out without sacrificing BOLD-sensitivity when compared to EPI. Furthermore, we characterize the intrinsic trade-off between specificity and resolution of the BOLD response under varying TE.
ER -