Association of oxygen reserve index with different nasal oxygen flow rates during sedated gastrointestinal endoscopy: A retrospective cohort study.

  1. 1Department of Anesthesiology and Reanimation, Yozgat Bozok University Training and Research Hospital, Yozgat, Turkey.

Abstract

Purpose

Supplemental oxygen is routinely given during sedated gastrointestinal endoscopy, but the optimal nasal flow rate remains uncertain.Objectives

This study evaluates which oxygen flow strategy is associated with the most balanced clinical monitoring profile for maintaining peri-procedural oxygenation.Design

Medical records of adult patients undergoing gastrointestinal endoscopy under sedation were retrospectively reviewed. We categorized patients into three oxygen flow groups (≤4, 5-6, and 7-8 L/min). We compared Oxygen Reserve Index (Ori), peripheral oxygen saturation (SpO₂), and oxygenation outcomes among these groups.Methods

Data from consecutive adult patients who underwent sedated gastrointestinal endoscopy between January 2023 and March 15, 2024, were evaluated retrospectively within three structured supplemental oxygen flow rate configurations: Group I (≤4 L/min; n = 71), Group II (5-6 L/min; n = 62), and Group III (7-8 L/min; n = 53). Longitudinal tracking dynamics of multi-dimensional oxy-hemodynamic parameters, including the Oxygen Reserve Index (ORi), regional cerebral oxygen saturation (rScO₂), Plethysmography Variability Index (PVI), and mean arterial pressure (MAP), were systematically analyzed utilizing a definitive Linear Mixed-Effects Model (LMM) restricted to a robust 15-minute operational support window.Results

Longitudinal trajectories analyzed via LMM demonstrated a statistically significant flow rate × time interaction effect for continuous ORi values across the temporal milestones (p < 0.001). Group III demonstrated the highest oxygen reserve expansions, while Group II sustained intermediate ORi buffer levels while safely holding traditional peripheral oxygen saturation (SpO₂) constant at the maximum physiological ceiling. Due to a low baseline incidence of clinical adverse outcomes (overall desaturation rate of 2.7%), formal inferential multivariable risk adjustments were omitted, and complications were monitored purely via non-inferential descriptive distributions.Conclusions

In this retrospective single-center cohort, higher humidified oxygen flow rates were associated with higher ORi trajectories during sedated gastrointestinal endoscopy. A 6 L/min flow was associated with intermediate ORi values while maintaining high SpO₂; however, the optimal oxygen flow and the clinical value of ORi-guided titration cannot be established from this observational dataset and require prospective randomized evaluation with direct PaO₂ measurement. ORi appears to be a useful tool, especially in the elderly for individualized oxygen therapy.

Related

  1. Comparative performance of pre- and post-endoscopic risk scores for outcome prediction in endoscopy-confirmed upper gastrointestinal bleeding in the emergency department : A retrospective single-center study
    Emre Oner, Niyazi Ilhan, Yasar Catal +3
    MedicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  2. Dissociation Between Symptom Burden and Structural Pathology in Patients Undergoing Upper Gastrointestinal Endoscopy: A Retrospective Single-Center Study Using Latent Class Analysis
    Linda Grantiņa, Evija Nagle, Maksims Zolovs +6
    Medicina (Kaunas, Lithuania)Peer-reviewedCC BYFull textGeneral medicineEurope PMC
  3. Association Between Iron-Deficiency Anemia and Endoscopic Findings in Patients Undergoing Upper Gastrointestinal (GI) Endoscopy
    Asma Khan, Muhammad Ayhan Amir, Medhini Roy Bhojanapu +7
    CureusPeer-reviewedCC BY 4.0Full textGeneral medicinePMCEurope PMC
  4. Diagnostic Yield of Opportunistic Upper Gastrointestinal Endoscopy During Elective Colonoscopy in Asymptomatic Patients: A Retrospective Cross-Sectional Study.
    Caroline Assis Aleixo Chaves Freitas, Sandro Rodrigues Chaves, Rafael P Pessoa +6
    CureusPeer-reviewedCC BYFull textGeneral medicineEurope PMC
  5. Association between hemoglobin A1c levels and coronary flow reserve in angina with nonobstructive coronary arteries: a retrospective observational study
    Keisuke Shirasaki, Takanori Ishida, Kentaro Niiya +5
    BMC Cardiovascular DisordersPeer-reviewedCC BY 4.0Full textCardiovascular medicinePMC
BibTeX
@article{kara2026association,
  title = {{Association of oxygen reserve index with different nasal oxygen flow rates during sedated gastrointestinal endoscopy: A retrospective cohort study.}},
  author = {Mehmet Kara and Yesim Andiran Senayli and Cevdet Yardimci and Meral Kanbak},
  journal = {Therapeutic advances in gastroenterology},
  year = {2026},
  month = nov,
  doi = {10.1177/17562848261508796},
  url = {https://europepmc.org/article/MED/43080717},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Association of oxygen reserve index with different nasal oxygen flow rates during sedated gastrointestinal endoscopy: A retrospective cohort study.
AU  - Mehmet Kara
AU  - Yesim Andiran Senayli
AU  - Cevdet Yardimci
AU  - Meral Kanbak
PY  - 2026
DA  - 2026/11/13
JO  - Therapeutic advances in gastroenterology
DO  - 10.1177/17562848261508796
UR  - https://europepmc.org/article/MED/43080717
AB  - Purpose  Supplemental oxygen is routinely given during sedated gastrointestinal endoscopy, but the optimal nasal flow rate remains uncertain.Objectives  This study evaluates which oxygen flow strategy is associated with the most balanced clinical monitoring profile for maintaining peri-procedural oxygenation.Design  Medical records of adult patients undergoing gastrointestinal endoscopy under sedation were retrospectively reviewed. We categorized patients into three oxygen flow groups (≤4, 5-6, and 7-8 L/min). We compared Oxygen Reserve Index (Ori), peripheral oxygen saturation (SpO₂), and oxygenation outcomes among these groups.Methods  Data from consecutive adult patients who underwent sedated gastrointestinal endoscopy between January 2023 and March 15, 2024, were evaluated retrospectively within three structured supplemental oxygen flow rate configurations: Group I (≤4 L/min; n = 71), Group II (5-6 L/min; n = 62), and Group III (7-8 L/min; n = 53). Longitudinal tracking dynamics of multi-dimensional oxy-hemodynamic parameters, including the Oxygen Reserve Index (ORi), regional cerebral oxygen saturation (rScO₂), Plethysmography Variability Index (PVI), and mean arterial pressure (MAP), were systematically analyzed utilizing a definitive Linear Mixed-Effects Model (LMM) restricted to a robust 15-minute operational support window.Results  Longitudinal trajectories analyzed via LMM demonstrated a statistically significant flow rate × time interaction effect for continuous ORi values across the temporal milestones (p < 0.001). Group III demonstrated the highest oxygen reserve expansions, while Group II sustained intermediate ORi buffer levels while safely holding traditional peripheral oxygen saturation (SpO₂) constant at the maximum physiological ceiling. Due to a low baseline incidence of clinical adverse outcomes (overall desaturation rate of 2.7%), formal inferential multivariable risk adjustments were omitted, and complications were monitored purely via non-inferential descriptive distributions.Conclusions  In this retrospective single-center cohort, higher humidified oxygen flow rates were associated with higher ORi trajectories during sedated gastrointestinal endoscopy. A 6 L/min flow was associated with intermediate ORi values while maintaining high SpO₂; however, the optimal oxygen flow and the clinical value of ORi-guided titration cannot be established from this observational dataset and require prospective randomized evaluation with direct PaO₂ measurement. ORi appears to be a useful tool, especially in the elderly for individualized oxygen therapy.
SN  - 1756-283X
SN  - 1756-2848
ER  -