Predicting survival beyond 5 years on continuous-flow left ventricular assist device: a landmark analysis from the STELLAR registry.
5 affiliations
- 1Heart Failure Center, Department of Thoracic and Cardiovascular Surgery, Herz- und Diabeteszentrum Nordrhein-Westfalen (HDZ NRW), University Hospital of the Ruhr-University Bochum, Georgstraße 11, 32545 Bad Oeynhausen, Germany.
- 2Department of Cardiology, Copenhagen University Hospital, Copenhagen, Denmark.
- 3Department of Cardiothoracic Surgery, Copenhagen University Hospital, Copenhagen, Denmark.
- 4Department of Clinical Medicine, University of Copenhagen, Copenhagen, Denmark.
- 5Abbott, Chicago, IL, USA.
Abstract
Introduction
Five-year survival after continuous-flow left ventricular assist device (LVAD) implantation has improved substantially, resulting in a growing population of ultra-long-term LVAD patients, defined as 5 years and longer survival on LVAD. Remarkably, determinants of mortality beyond the 5-year landmark remain poorly characterized, and ultra-long-term outcomes are rarely investigated.Methods
We performed a large bicentre observational landmark analysis including patients who survived at least 5 years on LVAD support. Implanted devices included HeartMate II, HeartWare (HVAD), and HeartMate 3. Clinical, laboratory, echocardiographic, and haemodynamic parameters at the 5-year time point were evaluated to represent predictors of mortality. Cox proportional hazards regression was used to identify independent predictors of mortality from the 5-year landmark. Model discrimination was assessed using Harrell's C-index and time-dependent area under the curve.Results
Among 201 patients surviving ≥5 years on LVAD support, 189 had complete data for multivariable analysis. Median age at implantation was 59.9 years (IQR 52.6-65.8), and 86% were male. During post-landmark follow-up, 77 deaths occurred. Age (HR 1.04 per year, 95% CI 1.02-1.07; P = .002), haemoglobin (HR 0.84 per mmol/l, 95% CI 0.73-0.97; P = .016), MELD-XI score (HR 1.10 per unit, 95% CI 1.06-1.14; P < .001), and implantable cardioverter-defibrillator presence (HR 1.60, 95% CI 1.00-2.54; P = .049) were independently associated with mortality beyond the 5-year landmark. The model showed acceptable discrimination (Harrell's C-index ∼0.74). LVAD model was not independently associated with post-landmark mortality (likelihood-ratio P = .63).Conclusion
Among patients who have already survived 5 years on continuous-flow LVAD support, subsequent mortality was associated with routinely available markers of physiological and end-organ reserve. These findings characterize risk specifically in prevalent long-term LVAD recipients and warrant external validation.
Related
- Chart-Recorded Hourly Patient Fluid-Removal Intensity and 90-Day Mortality After a 12-Hour Landmark During Continuous Renal Replacement Therapy
- Registry-defined incident chronic kidney disease following acute kidney injury after primary PCI for STEMI and its association with long-term outcomes: a multicenter landmark analysis
- Device-detected new-onset atrial fibrillation after dual-chamber pacemaker implantation in patients with sick sinus syndrome under managed ventricular pacing: a risk nomogram from the 3-month landmark
- Postdiagnostic pretreatment risk stratification for chondrosarcoma survival using routinely available registry variables: a SEER-based temporal validation study
- Regional disparities in lung cancer surgery and survival in South Korea: a nationwide population-based retrospective cohort study using linked cancer registry and national health insurance data
BibTeX
@article{velasquezsilva2026predicting,
title = {{Predicting survival beyond 5 years on continuous-flow left ventricular assist device: a landmark analysis from the STELLAR registry.}},
author = {Claudio Velásquez-Silva and William H Nielsen and Christian H Møller and Kasper Rossing and Angelika Costard-Jäckle and René Schramm and Michiel Morshuis and Jan F Gummert and Finn Gustafsson and Sebastian V Rojas and Henrik Fox},
journal = {ESC heart failure},
year = {2026},
month = aug,
doi = {10.1093/eschf/xvag257},
url = {https://europepmc.org/article/MED/42841476},
note = {CC BY-NC},
}
RIS
TY - JOUR
TI - Predicting survival beyond 5 years on continuous-flow left ventricular assist device: a landmark analysis from the STELLAR registry.
AU - Claudio Velásquez-Silva
AU - William H Nielsen
AU - Christian H Møller
AU - Kasper Rossing
AU - Angelika Costard-Jäckle
AU - René Schramm
AU - Michiel Morshuis
AU - Jan F Gummert
AU - Finn Gustafsson
AU - Sebastian V Rojas
AU - Henrik Fox
PY - 2026
DA - 2026/08/01
JO - ESC heart failure
DO - 10.1093/eschf/xvag257
UR - https://europepmc.org/article/MED/42841476
AB - Introduction Five-year survival after continuous-flow left ventricular assist device (LVAD) implantation has improved substantially, resulting in a growing population of ultra-long-term LVAD patients, defined as 5 years and longer survival on LVAD. Remarkably, determinants of mortality beyond the 5-year landmark remain poorly characterized, and ultra-long-term outcomes are rarely investigated.Methods We performed a large bicentre observational landmark analysis including patients who survived at least 5 years on LVAD support. Implanted devices included HeartMate II, HeartWare (HVAD), and HeartMate 3. Clinical, laboratory, echocardiographic, and haemodynamic parameters at the 5-year time point were evaluated to represent predictors of mortality. Cox proportional hazards regression was used to identify independent predictors of mortality from the 5-year landmark. Model discrimination was assessed using Harrell's C-index and time-dependent area under the curve.Results Among 201 patients surviving ≥5 years on LVAD support, 189 had complete data for multivariable analysis. Median age at implantation was 59.9 years (IQR 52.6-65.8), and 86% were male. During post-landmark follow-up, 77 deaths occurred. Age (HR 1.04 per year, 95% CI 1.02-1.07; P = .002), haemoglobin (HR 0.84 per mmol/l, 95% CI 0.73-0.97; P = .016), MELD-XI score (HR 1.10 per unit, 95% CI 1.06-1.14; P < .001), and implantable cardioverter-defibrillator presence (HR 1.60, 95% CI 1.00-2.54; P = .049) were independently associated with mortality beyond the 5-year landmark. The model showed acceptable discrimination (Harrell's C-index ∼0.74). LVAD model was not independently associated with post-landmark mortality (likelihood-ratio P = .63).Conclusion Among patients who have already survived 5 years on continuous-flow LVAD support, subsequent mortality was associated with routinely available markers of physiological and end-organ reserve. These findings characterize risk specifically in prevalent long-term LVAD recipients and warrant external validation.
SN - 2055-5822
ER -