Cryogenic Optical Characteristics of S-FPL51 and S-LAH71: Refractive index, Transmission and Thermal expansion
Abstract
Several near-infrared instruments on upcoming extremely large telescopes use a combination of OHARA S-FPL51 and S-LAH71 glass prisms to correct for the atmospheric differential refraction. Because large parts of these instruments are contained within a vessel cooled to liquid nitrogen temperatures, the changes in optical and mechanical properties should be considered during the design phase. In this report, we provide an update to our continuing efforts to characterize the S-FPL51 and S-LAH71 glass under cryogenic conditions. These efforts include a measurement of the refractive index (293 K, 100 K and 80 K), transmission measurements (293 K, 77 K and 43 K) and a determination of the coefficient of thermal expansion (between 293 K and 45 K). We will describe the cryogenic test setups that we have used to obtain our results, and provide summarizing equations of these material properties. This characterization will prove useful for conceptual design trade-offs, mechanical interface solutions and detailed optical design for future near-infrared instrumentation on large telescopes.
Versions
Related
- Steepening Optical Slopes in Exoplanet Transmission Spectra with Charged Hazes
- The Optical Expansion Scalar in Cosmological Perturbation Theory
- Multi-Band Optical Variability Characteristics of the γ-ray emitting blazar 1ES 0647+250 during its 2020 flare
- Construction of a Global Atmospheric Refractivity Model for Optical Wavelengths Based on Temporal Evolution Characteristics
- A comparative analysis of the long-term optical variability characteristics of narrow and broad-line Seyfert 1 galaxies at z > 0.8
BibTeX
@misc{born2026cryogenic,
title = {{Cryogenic Optical Characteristics of S-FPL51 and S-LAH71: Refractive index, Transmission and Thermal expansion}},
author = {J. A. van den Born and E. Elswijk and E. Dijkstra and P. van Nijnatten and A. W. Janssen and R. Navarro},
howpublished = {arXiv},
year = {2026},
month = oct,
doi = {10.48550/arxiv.2610.41481},
eprint = {2610.41481},
archivePrefix = {arXiv},
url = {https://arxiv.org/abs/2610.41481},
note = {CC BY-SA 4.0},
}
RIS
TY - UNPB
TI - Cryogenic Optical Characteristics of S-FPL51 and S-LAH71: Refractive index, Transmission and Thermal expansion
AU - J. A. van den Born
AU - E. Elswijk
AU - E. Dijkstra
AU - P. van Nijnatten
AU - A. W. Janssen
AU - R. Navarro
PY - 2026
DA - 2026/10/30
PB - arXiv
DO - 10.48550/arxiv.2610.41481
UR - https://arxiv.org/abs/2610.41481
AB - Several near-infrared instruments on upcoming extremely large telescopes use a combination of OHARA S-FPL51 and S-LAH71 glass prisms to correct for the atmospheric differential refraction. Because large parts of these instruments are contained within a vessel cooled to liquid nitrogen temperatures, the changes in optical and mechanical properties should be considered during the design phase. In this report, we provide an update to our continuing efforts to characterize the S-FPL51 and S-LAH71 glass under cryogenic conditions. These efforts include a measurement of the refractive index (293 K, 100 K and 80 K), transmission measurements (293 K, 77 K and 43 K) and a determination of the coefficient of thermal expansion (between 293 K and 45 K). We will describe the cryogenic test setups that we have used to obtain our results, and provide summarizing equations of these material properties. This characterization will prove useful for conceptual design trade-offs, mechanical interface solutions and detailed optical design for future near-infrared instrumentation on large telescopes.
ER -