Skip to content
DraconiticResearch
Search Sources API
276,906 studies31 sourcesUpdated 20 min ago
Peer-reviewedCC BYAudiology research

Exploratory Pilot Study of Artifact Load and Saccadic and Smooth Pursuit Measurements in Video-Oculography in Young Adults.

  1. 1Department of Audiology and Speech-Language Pathology, SRM School of Allied Health Sciences, Faculty of Medicine and Health Sciences, SRM Institute of Science and Technology, Kattankulathur, Chengalpattu 603203, Tamil Nadu, India.

Abstract

Background/Objectives: Video-oculography (VOG) recordings may contain physiological and non-physiological artifacts that can mimic genuine oculomotor abnormality, particularly along the vertical axis. This exploratory pilot study introduced the VOG Artifact Assessment Questionnaire (VAQ) and examined the association between artifact load and axis-specific saccadic and smooth pursuit measures. Methods: Thirty healthy adults aged 18-25 years underwent horizontal and vertical saccade and smooth pursuit testing on a VOG system. Artifacts were scored using the 17-item VAQ in real time during recording and offline from the stored recordings (all 17 items at T1; the 11 items that can be scored offline at T2), and the Total Artifact Score (TAS; range of 0-25) was calculated from the final item scores. Associations between the continuous TAS (rank order) and latency, peak velocity, precision, and gain were analyzed using Kendall's τ-b and a linear mixed model, with Holm correction; participants were also divided into tertile groups by TAS rank order. Results: The VAQ showed high internal consistency (Cronbach's α = 0.913). No saccade or smooth pursuit measure was associated with the continuous TAS (Kendall's τ-b -0.15 to +0.14; all unadjusted p ≥ 0.26; all Holm-adjusted p = 1.0), and this held at every flag threshold tested (k = 1 to 7 and a mixed rule; no unadjusted p < 0.05 in 64 tests). Comparison across TAS-tertile groups (n = 11, 11 and 8) yielded the same result (τ-b -0.16 to +0.13; all unadjusted p ≥ 0.28). An exploratory pooled mixed model also showed no association (-0.015 SD per TAS point, 95% CI -0.053 to +0.022). Conclusions: In this small sample of healthy adults, no association between VAQ-derived artifact load and saccadic or smooth pursuit measures was detected, although wide confidence intervals mean that moderate effects cannot be excluded. The VAQ and its provisional categories remain unvalidated and require testing in larger, independent and clinical samples with blinded raters.

Related

  1. Can non-invasive surface measurements predict abdominal wall myofascial mechanics? An exploratory study
    Grégoire Deshairs, Arthur Jourdan, Catherine Masson +2
    Multidisciplinary Biomechanics JournalPeer-reviewedCC BY 4.0Full textCell biologyHAL
  2. Saccadic omission revisited: What saccade-induced smear looks like.
    Richard Schweitzer, Mara Doering, Thomas Seel +2
    Psychological ReviewPeer-reviewedLicence not statedFull text16 citedNeuroscienceOpenAlex
  3. Saccadic Neural Command Estimation via Forward Dynamics Control: Influence of Extraocular Muscle Geometry on Physiological Plausibility
    Even Harsigny, Pablo Alvarez Corrales, Michel Duprez +1
    Multidisciplinary Biomechanics JournalPeer-reviewedCC BY 4.0Full textNeuroscienceHAL
  4. Pre-saccadic suppression and compensatory cortical distortions support predictive visual remapping
    Xize Xu, Sachira Denagamage, Anirvan S. Nandy +1
    bioRxivPreprintCC BYFull textNeurosciencebioRxivPMC
  5. Species-specific sensorimotor noise levels explain saccadic suppression strength differences between macaques and zebrafish
    Giulia Soto, Florian A. Dehmelt, Matthias P. Baumann +5
    iSciencePeer-reviewedCC BY 4.0Full textMolecular biology & gene regulationNeuroscienceCell PressCrossrefPMC
BibTeX
@article{ramamoorthy2026exploratory,
  title = {{Exploratory Pilot Study of Artifact Load and Saccadic and Smooth Pursuit Measurements in Video-Oculography in Young Adults.}},
  author = {Santhoshi Ramamoorthy and Kala Samayan},
  journal = {Audiology research},
  year = {2026},
  month = nov,
  doi = {10.3390/audiolres16060175},
  url = {https://europepmc.org/article/MED/43081440},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Exploratory Pilot Study of Artifact Load and Saccadic and Smooth Pursuit Measurements in Video-Oculography in Young Adults.
AU  - Santhoshi Ramamoorthy
AU  - Kala Samayan
PY  - 2026
DA  - 2026/11/21
JO  - Audiology research
DO  - 10.3390/audiolres16060175
UR  - https://europepmc.org/article/MED/43081440
AB  - Background/Objectives: Video-oculography (VOG) recordings may contain physiological and non-physiological artifacts that can mimic genuine oculomotor abnormality, particularly along the vertical axis. This exploratory pilot study introduced the VOG Artifact Assessment Questionnaire (VAQ) and examined the association between artifact load and axis-specific saccadic and smooth pursuit measures. Methods: Thirty healthy adults aged 18-25 years underwent horizontal and vertical saccade and smooth pursuit testing on a VOG system. Artifacts were scored using the 17-item VAQ in real time during recording and offline from the stored recordings (all 17 items at T1; the 11 items that can be scored offline at T2), and the Total Artifact Score (TAS; range of 0-25) was calculated from the final item scores. Associations between the continuous TAS (rank order) and latency, peak velocity, precision, and gain were analyzed using Kendall's τ-b and a linear mixed model, with Holm correction; participants were also divided into tertile groups by TAS rank order. Results: The VAQ showed high internal consistency (Cronbach's α = 0.913). No saccade or smooth pursuit measure was associated with the continuous TAS (Kendall's τ-b -0.15 to +0.14; all unadjusted p ≥ 0.26; all Holm-adjusted p = 1.0), and this held at every flag threshold tested (k = 1 to 7 and a mixed rule; no unadjusted p < 0.05 in 64 tests). Comparison across TAS-tertile groups (n = 11, 11 and 8) yielded the same result (τ-b -0.16 to +0.13; all unadjusted p ≥ 0.28). An exploratory pooled mixed model also showed no association (-0.015 SD per TAS point, 95% CI -0.053 to +0.022). Conclusions: In this small sample of healthy adults, no association between VAQ-derived artifact load and saccadic or smooth pursuit measures was detected, although wide confidence intervals mean that moderate effects cannot be excluded. The VAQ and its provisional categories remain unvalidated and require testing in larger, independent and clinical samples with blinded raters.
SN  - 2039-4330
SN  - 2039-4349
ER  -