Skip to content
DraconiticResearch
Search Sources API
203,203 studies31 sourcesUpdated 5 min ago
Peer-reviewedCC BY-NCUltrasonics sonochemistry

Cavitation-eroded piezoelectric ceramics as finite mechano-electrochemical transducers.

  1. 1Department of Civil and Environmental Engineering, Hanyang University, Seoul 04763, South Korea.
  2. 2Department of Civil and Environmental Engineering, Hanyang University, Seoul 04763, South Korea. Electronic address: [email protected].

Abstract

Piezoelectric ceramics are being explored as mechanically powered materials for energy-environmental processes, but the relationship between energy transduction and material durability remains unclear. We examined four piezoelectric materials (BaTiO₃, ZnO, K0.5Na0.5NbO₃, and PbZr0.53Ti0.47O₃) under 40 kHz ultrasonic cavitation. The pressure criterion for reactive oxygen species (ROS) formation through water compression (2.8-8.1 GPa) exceeded the 1.13 GPa compressed-bubble pressure obtained from the bubble-collapse calculation. The electron-energy analysis provides a thermal-equilibrium reference rather than a prediction of plasma-derived ROS yields. The powder-free control showed only 0.7% and 1.9% tetracycline (TC) removal after 120 and 480 min, respectively. The open-circuit piezoelectric potentials calculated for 1 μm particles at the 1.13 GPa compressed-bubble pressure (9-210 V) exceeded the electrochemical thresholds (0.33-2.8 V), and the powders showed persistent contact-potential shifts up to - 318 mV and charge storage 32-55 times beyond the electrical double-layer limit. Cavitation-induced irreversible lattice strain and selective A-site ion leaching were accompanied by elbow-shaped TC degradation kinetics with performance declining from approximately 67% to 1-3% over five cycles. Mott-Schottky and impedance analyses indicated that interfacial electrochemical states were irreversibly altered. The tested powders are described here as finite mechano-electrochemical transducers whose operation is accompanied by irreversible material changes and declining activity. The relevant design criterion for sustainable piezoelectric environmental applications should include redox output, material lifetime, recoverability, and ion-release risk as well as the first-cycle activity.

Related

  1. Warm Isostatic vs. Cold Uniaxial Pressing in All-Solid-State Battery Cathodes: Linking Microstructure, Transport, and Mechano-Electrochemical Response
    Siwar Ben Hadj Ali, Lei Qin, Pempa Tshering Bhutia +6
    ChemRxivPreprintLicence not statedGeneral chemistryChemRxiv
  2. Mechano-electrochemical energy harvesting and self-powered sensing via dynamic liquid metal–electrolyte interfaces
    Xiangbo Zhou, Hongda Lu, Jialu Wang +8
    Science AdvancesPeer-reviewedCC BY-NC 4.0Full textElectrochemistry & energySci. Adv.CrossrefPMC
  3. Kraft Cooking Kinetics of Poplar Wood Chips Pretreated via a Mechano-Enzymatic Method for Further Nanocellulose Production
    Arthur Valencony, Sandra Tapin-Lingua, Seyedeh Hadis Hashemi +1
    Molecules (Basel, Switzerland)Peer-reviewedCC BYFull textGeneral chemistryEurope PMC
  4. Ferroelectric polymer-based flexible and transparent transducers for biomedical ultrasound and photoacoustic imaging.
    Lin Zhang, Senyang Xiao, Shenghao Wu +2
    PhotoacousticsPeer-reviewedCC BYFull textMaterials & polymersEurope PMC
  5. Chemometrics reshapes the role of biosensors: from signal transducers to intelligent analytical systems
    Wanda Cimmino, Alessandra Glovi, Antonella Miglione +2
    Biosensors and Biomolecular ElectronicsPeer-reviewedCC BY-NC-NDFull text7 citedAnalytical chemistryOpenAlex
BibTeX
@article{park2026cavitationeroded,
  title = {{Cavitation-eroded piezoelectric ceramics as finite mechano-electrochemical transducers.}},
  author = {Gunn Park and Jae-Woo Park},
  journal = {Ultrasonics sonochemistry},
  year = {2026},
  month = oct,
  doi = {10.1016/j.ultsonch.2026.108101},
  url = {https://europepmc.org/article/MED/42863376},
  note = {CC BY-NC},
}
RIS
TY  - JOUR
TI  - Cavitation-eroded piezoelectric ceramics as finite mechano-electrochemical transducers.
AU  - Gunn Park
AU  - Jae-Woo Park
PY  - 2026
DA  - 2026/10/09
JO  - Ultrasonics sonochemistry
DO  - 10.1016/j.ultsonch.2026.108101
UR  - https://europepmc.org/article/MED/42863376
AB  - Piezoelectric ceramics are being explored as mechanically powered materials for energy-environmental processes, but the relationship between energy transduction and material durability remains unclear. We examined four piezoelectric materials (BaTiO₃, ZnO, K0.5Na0.5NbO₃, and PbZr0.53Ti0.47O₃) under 40 kHz ultrasonic cavitation. The pressure criterion for reactive oxygen species (ROS) formation through water compression (2.8-8.1 GPa) exceeded the 1.13 GPa compressed-bubble pressure obtained from the bubble-collapse calculation. The electron-energy analysis provides a thermal-equilibrium reference rather than a prediction of plasma-derived ROS yields. The powder-free control showed only 0.7% and 1.9% tetracycline (TC) removal after 120 and 480 min, respectively. The open-circuit piezoelectric potentials calculated for 1 μm particles at the 1.13 GPa compressed-bubble pressure (9-210 V) exceeded the electrochemical thresholds (0.33-2.8 V), and the powders showed persistent contact-potential shifts up to - 318 mV and charge storage 32-55 times beyond the electrical double-layer limit. Cavitation-induced irreversible lattice strain and selective A-site ion leaching were accompanied by elbow-shaped TC degradation kinetics with performance declining from approximately 67% to 1-3% over five cycles. Mott-Schottky and impedance analyses indicated that interfacial electrochemical states were irreversibly altered. The tested powders are described here as finite mechano-electrochemical transducers whose operation is accompanied by irreversible material changes and declining activity. The relevant design criterion for sustainable piezoelectric environmental applications should include redox output, material lifetime, recoverability, and ion-release risk as well as the first-cycle activity.
SN  - 1350-4177
SN  - 1873-2828
ER  -