Trigonometric cyber-biomedical phase embedding for IoMT attack detection
- 1Department of Information System, Faculty of Computing and Information Technology, King Abdulaziz University, Jeddah, Saudi Arabia
- 2Department of Software Engineering, College of Computer Science and Engineering, University of Jeddah, Jeddah, Saudi Arabia
Abstract
Internet of Medical Things (IoMT) attacks may disrupt consistency between device communication and patient measurements even when individual cyber or biomedical values remain plausible. We address this representation gap using a leakage-controlled trigonometric cyber-biomedical phase embedding for IoMT attack detection. Within each training split, normal records define benign empirical reference maps. Prespecified cyber/network and biomedical variables are transformed through training-only empirical distribution functions into rank-derived circular coordinates, represented by sine-cosine components and cyber-biomedical phase-gap variables that quantify disagreement relative to benign operation. Here, phase denotes an empirical benign-reference coordinate rather than physiological waveform phase. The framework was evaluated on WUSTL-EHMS-2020 using 16,318 records, 26 cyber/network candidate variables, eight biomedical candidate variables, and ten repeated stratified 70/30 train-test splits. Relative to raw cyber-biomedical fusion, the complete augmented representation increased balanced accuracy from 0.730 to 0.738, attack recall from 0.461 to 0.478, F1-score from 0.627 to 0.641, and PR-AUC from 0.740 to 0.751. Corrected paired repeated-holdout analysis supported gains in balanced accuracy, attack recall, F1-score, and PR-AUC, whereas the smaller ROC-AUC difference was not statistically distinguishable from zero. Component-level ablation identified the phase-gap block as the strongest source of incremental predictive value, achieving balanced accuracy of 0.742, attack recall of 0.486, F1-score of 0.647, and PR-AUC of 0.764. These findings indicate that modelling cyber-biomedical disagreement relative to benign reference behaviour provides measurable additional detection information beyond direct raw-variable fusion, while the phase-gap block represents the empirically preferred reduced configuration.
Related
- Transformer-aided guard: A hybrid spatio-temporal framework for confidence-aware intrusion detection in cyber-physical systems
- CASTLE: Cell-type aware SpaTial domain detection via contrastive learning embedding
- Rip current detection in nearshore areas through UAV video analysis using optical flow and almost local-isometric embedding techniques on the sphere
- Automated cloud-edge cyber-physical IoT infrastructure for optimizing the agricultural water-energy nexus and yield
- Beyond resemblance: model-departing thoracic constriction in an ant-mimicking spider is associated with post-attack survival
BibTeX
@article{bahaddad2026trigonometric,
title = {{Trigonometric cyber-biomedical phase embedding for IoMT attack detection}},
author = {Adel Aboud Bahaddad and Ahmed Mohammed Alghamdi},
journal = {PLOS One},
year = {2026},
month = nov,
doi = {10.1371/journal.pone.0353225},
url = {https://doi.org/10.1371/journal.pone.0353225},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Trigonometric cyber-biomedical phase embedding for IoMT attack detection
AU - Adel Aboud Bahaddad
AU - Ahmed Mohammed Alghamdi
PY - 2026
DA - 2026/11/25
JO - PLOS One
DO - 10.1371/journal.pone.0353225
UR - https://doi.org/10.1371/journal.pone.0353225
AB - Internet of Medical Things (IoMT) attacks may disrupt consistency between device communication and patient measurements even when individual cyber or biomedical values remain plausible. We address this representation gap using a leakage-controlled trigonometric cyber-biomedical phase embedding for IoMT attack detection. Within each training split, normal records define benign empirical reference maps. Prespecified cyber/network and biomedical variables are transformed through training-only empirical distribution functions into rank-derived circular coordinates, represented by sine-cosine components and cyber-biomedical phase-gap variables that quantify disagreement relative to benign operation. Here, phase denotes an empirical benign-reference coordinate rather than physiological waveform phase. The framework was evaluated on WUSTL-EHMS-2020 using 16,318 records, 26 cyber/network candidate variables, eight biomedical candidate variables, and ten repeated stratified 70/30 train-test splits. Relative to raw cyber-biomedical fusion, the complete augmented representation increased balanced accuracy from 0.730 to 0.738, attack recall from 0.461 to 0.478, F1-score from 0.627 to 0.641, and PR-AUC from 0.740 to 0.751. Corrected paired repeated-holdout analysis supported gains in balanced accuracy, attack recall, F1-score, and PR-AUC, whereas the smaller ROC-AUC difference was not statistically distinguishable from zero. Component-level ablation identified the phase-gap block as the strongest source of incremental predictive value, achieving balanced accuracy of 0.742, attack recall of 0.486, F1-score of 0.647, and PR-AUC of 0.764. These findings indicate that modelling cyber-biomedical disagreement relative to benign reference behaviour provides measurable additional detection information beyond direct raw-variable fusion, while the phase-gap block represents the empirically preferred reduced configuration.
SN - 1932-6203
ER -