Skip to content
DraconiticResearch
Search Sources API
190,332 studies31 sourcesUpdated 57 min ago
Peer-reviewedCC BYJournal of clinical medicine

Clinical Comparison of Articulating Paper, Intraoral Scanner, and Jaw-Tracking Device for Occlusal Analysis

  1. 1Prosthetic Dentistry and Dental Materials Department, Iuliu Hațieganu University of Medicine and Pharmacy, 32 Clinicilor Street, 400006 Cluj-Napoca, Romania
  2. 2Department of Pharmacology, Toxicology and Clinical Pharmacology, Iuliu Haţieganu University of Medicine and Pharmacy, 400337 Cluj-Napoca, Romania

Abstract

Recent advances in digital dentistry have transformed occlusal analysis through the introduction of new digital workflows for recording static and dynamic occlusal contacts. This clinical study aimed to evaluate the reliability and concordance of two digital clinical workflows, the Medit i700 intraoral scanner and the Tizian JMA-Optic jaw-tracking system, using 100 μm articulating paper as the reference comparator for static and dynamic occlusal-contact recordings. Materials and Methods: Twenty-six participants aged 20 to 25 years were included in this study. For each participant, static and dynamic occlusal contacts were recorded in maximum intercuspation position (MIP), protrusive, and right and left laterotrusive movements, using 100 μm articulating paper, Medit i700, and Tizian JMA-Optic system. Intra-rater reliability was assessed using ICC(A,1) for the quantitative number of MIP contacts and Cohen’s kappa for dynamic occlusal-contact recordings. Sensitivity, specificity, positive predictive value, and negative predictive value of the digital systems were evaluated relative to the articulating-paper reference comparator. Agreement between articulating paper and the two digital workflows was assessed using the intraclass correlation coefficient for the quantitative variables. Results: Intra-rater reliability was generally high but varied according to the recording method and occlusal-contact category. Overall, the Medit i700 showed numerically higher sensitivity and positive predictive value point estimates in several dynamic occlusal-contact categories than Tizian JMA-Optic, while specificity and negative predictive values were generally high for both systems. Both digital workflows showed good overall agreement with articulating paper in recording the number of occlusal contacts in MIP. Agreement was good at arch level, poor in the anterior regions, and moderate in the posterior regions. Conclusions: Both digital workflows showed generally high intra-rater reliability for dynamic occlusal recordings, with reliability varying according to the occlusal-contact category. Both systems demonstrated good agreement with the articulating-paper reference comparator for quantifying occlusal contacts in MIP, although substantial differences in measured contact area were observed. The numerical differences between Medit i700 and Tizian JMA-Optic should be interpreted descriptively rather than as evidence of superiority of either workflow. Although the digital systems provide valuable quantitative information for occlusal analysis, articulating paper remains a widely used conventional method for clinical identification of occlusal contacts and served as the reference comparator in the present study.

Related

  1. Agreement and reproducibility of intraoral scan- versus CBCT-based three-dimensional implant position assessment in the posterior mandible — a paired in vitro method-comparison study
    Georg Hoene, Shabnam Shahpasand, Felix Karl Waffenschmidt +4
    International journal of implant dentistryPeer-reviewedCC BYFull textGeneral medicineEurope PMCDOAJ
  2. Occlusal Vertical Dimension Estimated from 3-Dimensional Facial Scans Using a Craniometric Equation: A Retrospective Clinical Study
    Louise Viel, Virginie Chuy, Justine Bouscasse +2
    The Journal of Prosthetic DentistryPeer-reviewedCC BY 4.0Full textGeneral biologyEpidemiology & public healthHAL
  3. A survey and review of eye-tracking in clinical practice
    F. B. Mulvey, O. M.-A. Amiebenomo, D. Atan +7
    medRxivPreprintAll rights reservedFull textNeurologymedRxiv
  4. Clinical Application of Speckle-tracking Echocardiography in Atherosclerotic Cardiovascular Disease
    Koki Nakanishi
    Journal of Atherosclerosis and ThrombosisPeer-reviewedCC BY-NC-SAFull textCardiovascular medicineJ-STAGE
  5. Changes in Temporomandibular Disorder Symptoms Following Occlusal Splint Therapy: A Prospective Single-Arm Before-After Study
    Juan Antonio Maldonado-Moreno, Luis Pablo Cruz-Hervert, Martha Elizabeth Tovar-Martínez +5
    CureusPeer-reviewedCC BYFull textGeneral medicineEurope PMC
BibTeX
@article{manziuc2026clinical,
  title = {{Clinical Comparison of Articulating Paper, Intraoral Scanner, and Jaw-Tracking Device for Occlusal Analysis}},
  author = {Manuela-Maria Manziuc and Mara Mihaela Savu and Flavia Groza and Ștefan Cristian Vesa and Cosmin Ifrim and George Burian and Maria Jarda and Manuela Tăut and Ana Ispas and Daniela Popa and Smaranda Buduru},
  journal = {Journal of clinical medicine},
  year = {2026},
  month = sep,
  doi = {10.3390/jcm15197587},
  url = {https://europepmc.org/article/PMC/PMC13665821},
  note = {CC BY},
}
RIS
TY  - JOUR
TI  - Clinical Comparison of Articulating Paper, Intraoral Scanner, and Jaw-Tracking Device for Occlusal Analysis
AU  - Manuela-Maria Manziuc
AU  - Mara Mihaela Savu
AU  - Flavia Groza
AU  - Ștefan Cristian Vesa
AU  - Cosmin Ifrim
AU  - George Burian
AU  - Maria Jarda
AU  - Manuela Tăut
AU  - Ana Ispas
AU  - Daniela Popa
AU  - Smaranda Buduru
PY  - 2026
DA  - 2026/09/30
JO  - Journal of clinical medicine
DO  - 10.3390/jcm15197587
UR  - https://europepmc.org/article/PMC/PMC13665821
AB  - Recent advances in digital dentistry have transformed occlusal analysis through the introduction of new digital workflows for recording static and dynamic occlusal contacts. This clinical study aimed to evaluate the reliability and concordance of two digital clinical workflows, the Medit i700 intraoral scanner and the Tizian JMA-Optic jaw-tracking system, using 100 μm articulating paper as the reference comparator for static and dynamic occlusal-contact recordings. Materials and Methods: Twenty-six participants aged 20 to 25 years were included in this study. For each participant, static and dynamic occlusal contacts were recorded in maximum intercuspation position (MIP), protrusive, and right and left laterotrusive movements, using 100 μm articulating paper, Medit i700, and Tizian JMA-Optic system. Intra-rater reliability was assessed using ICC(A,1) for the quantitative number of MIP contacts and Cohen’s kappa for dynamic occlusal-contact recordings. Sensitivity, specificity, positive predictive value, and negative predictive value of the digital systems were evaluated relative to the articulating-paper reference comparator. Agreement between articulating paper and the two digital workflows was assessed using the intraclass correlation coefficient for the quantitative variables. Results: Intra-rater reliability was generally high but varied according to the recording method and occlusal-contact category. Overall, the Medit i700 showed numerically higher sensitivity and positive predictive value point estimates in several dynamic occlusal-contact categories than Tizian JMA-Optic, while specificity and negative predictive values were generally high for both systems. Both digital workflows showed good overall agreement with articulating paper in recording the number of occlusal contacts in MIP. Agreement was good at arch level, poor in the anterior regions, and moderate in the posterior regions. Conclusions: Both digital workflows showed generally high intra-rater reliability for dynamic occlusal recordings, with reliability varying according to the occlusal-contact category. Both systems demonstrated good agreement with the articulating-paper reference comparator for quantifying occlusal contacts in MIP, although substantial differences in measured contact area were observed. The numerical differences between Medit i700 and Tizian JMA-Optic should be interpreted descriptively rather than as evidence of superiority of either workflow. Although the digital systems provide valuable quantitative information for occlusal analysis, articulating paper remains a widely used conventional method for clinical identification of occlusal contacts and served as the reference comparator in the present study.
SN  - 2077-0383
ER  -