Modified fourth-generation minimally invasive technique with a modified K-wire fixation technique for hallux valgus: a biomechanical and clinical study.
- 1Department of Trauma and Foot-Ankle Surgery, Guangdong Provincial Hospital of Chinese Medicine, Guangzhou, 510120, China.
- 2The Second Clinical College of Guangzhou University of Chinese Medicine, Guangzhou University of Chinese Medicine, Guangzhou, China.
- 3Department of Trauma and Foot-Ankle Surgery, Guangdong Provincial Hospital of Chinese Medicine, Guangzhou, 510120, China. [email protected].
Abstract
Background
Minimally invasive techniques have become prominent in hallux valgus (HV) correction. However, prevalent third and fourth-generation methods using the "in-out-in" screw fixation often involve extensive intraoperative fluoroscopy, a steep learning curve, and higher costs. This study introduces and evaluates a modified fourth-generation technique featuring an extra-articular transverse osteotomy combined with a modified Kirschner wire (K-wire) fixation technique and the concept of "fourth-dimensional correction" (dynamic and static assessment).Methods
The study comprised two parts. First, a finite element analysis (FEA) model was developed to compare the biomechanical performance (bone/implant stress, stability) of the modified K-wire fixation technique versus the standard "in-out-in" K-wire fixation at different lateral translation distances (4, 8, 12 mm). Second, a prospective case series of 108 patients (164 feet) with mild to severe HV who underwent the modified technique was analyzed. Outcomes included radiographic parameters (HVA, IMA, DMAA), the AOFAS score, complications, and intraoperative fluoroscopy usage.Results
FEA demonstrated that the modified K-wire fixation technique provided stability comparable to the "in-out-in" technique while exhibiting significantly lower stress on the K-wires, suggesting a reduced risk of pin fracture. Clinically, all osteotomy sites achieved bony union. Significant improvements were observed in the entire cohort: mean HVA corrected from 36.93°±9.32° to 9.57°±4.88°, mean IMA from 14.86°±3.82° to 6.08°±3.43°, and mean AOFAS score from 61.26 ± 6.97 to 88.90 ± 4.68 (all P < 0.01). Excellent correction was maintained across all severity subgroups. The mean intraoperative fluoroscopy shots were 4.14 ± 3.04 per foot, showing a distinct learning curve that stabilized after approximately 25 cases, with usage significantly lower than rates reported for traditional "in-out-in" methods.Conclusion
The modified fourth-generation minimally invasive technique with the modified K-wire fixation technique is biomechanically sound and clinically effective. It provides reliable radiographic and functional outcomes for HV of varying severities while substantially reducing intraoperative radiation exposure, offering a valuable alternative in the minimally invasive HV correction arsenal.
Related
- Biomechanical comparative analysis of minimally invasive decompression and minimally invasive fusion with internal fixation in the treatment of lumbar spinal stenosis with degenerative spondylolisthesis: a finite element study.
- Trivector Traction Suturing Technique in Minimally Invasive Root Coverage Procedures: A Report of Two Cases
- The Anatomic-Atraumatic-Anterior Reconstructive Technique (A-A-ART) for total hip arthroplasty: A step-by-step pictorial guide to a minimally invasive approach for hip osteoarthritis.
- Reconstruction with a novel pedicled mucoperiosteal hinge flap and dura suturing: a new minimally invasive concept and closure technique for endoscopic endonasal surgery
- Comparison of Minimally Invasive Colectomy Between Intra‐ Versus Extra‐Corporeal Anastomosis Technique (COMMIT Study): Short‐Term Analysis
BibTeX
@article{chen2026modified,
title = {{Modified fourth-generation minimally invasive technique with a modified K-wire fixation technique for hallux valgus: a biomechanical and clinical study.}},
author = {Pu Chen and Hua Guan and Enhui Feng and Jiachang Liang and Xinying He and Weiming Huang and Yiyin Xu and Jiewei Xie},
journal = {BMC musculoskeletal disorders},
year = {2026},
month = jul,
doi = {10.1186/s12891-026-10151-1},
url = {https://europepmc.org/article/MED/42928159},
note = {CC BY},
}
RIS
TY - JOUR
TI - Modified fourth-generation minimally invasive technique with a modified K-wire fixation technique for hallux valgus: a biomechanical and clinical study.
AU - Pu Chen
AU - Hua Guan
AU - Enhui Feng
AU - Jiachang Liang
AU - Xinying He
AU - Weiming Huang
AU - Yiyin Xu
AU - Jiewei Xie
PY - 2026
DA - 2026/07/28
JO - BMC musculoskeletal disorders
DO - 10.1186/s12891-026-10151-1
UR - https://europepmc.org/article/MED/42928159
AB - Background Minimally invasive techniques have become prominent in hallux valgus (HV) correction. However, prevalent third and fourth-generation methods using the "in-out-in" screw fixation often involve extensive intraoperative fluoroscopy, a steep learning curve, and higher costs. This study introduces and evaluates a modified fourth-generation technique featuring an extra-articular transverse osteotomy combined with a modified Kirschner wire (K-wire) fixation technique and the concept of "fourth-dimensional correction" (dynamic and static assessment).Methods The study comprised two parts. First, a finite element analysis (FEA) model was developed to compare the biomechanical performance (bone/implant stress, stability) of the modified K-wire fixation technique versus the standard "in-out-in" K-wire fixation at different lateral translation distances (4, 8, 12 mm). Second, a prospective case series of 108 patients (164 feet) with mild to severe HV who underwent the modified technique was analyzed. Outcomes included radiographic parameters (HVA, IMA, DMAA), the AOFAS score, complications, and intraoperative fluoroscopy usage.Results FEA demonstrated that the modified K-wire fixation technique provided stability comparable to the "in-out-in" technique while exhibiting significantly lower stress on the K-wires, suggesting a reduced risk of pin fracture. Clinically, all osteotomy sites achieved bony union. Significant improvements were observed in the entire cohort: mean HVA corrected from 36.93°±9.32° to 9.57°±4.88°, mean IMA from 14.86°±3.82° to 6.08°±3.43°, and mean AOFAS score from 61.26 ± 6.97 to 88.90 ± 4.68 (all P < 0.01). Excellent correction was maintained across all severity subgroups. The mean intraoperative fluoroscopy shots were 4.14 ± 3.04 per foot, showing a distinct learning curve that stabilized after approximately 25 cases, with usage significantly lower than rates reported for traditional "in-out-in" methods.Conclusion The modified fourth-generation minimally invasive technique with the modified K-wire fixation technique is biomechanically sound and clinically effective. It provides reliable radiographic and functional outcomes for HV of varying severities while substantially reducing intraoperative radiation exposure, offering a valuable alternative in the minimally invasive HV correction arsenal.
SN - 1471-2474
ER -