Augmented and standard baseplates demonstrate similar clinical and radiographic outcomes following reverse shoulder arthroplasty with the Arthrex modular Glenoid System
- 1Oregon Shoulder Institute, Medford, OR, USA
- 2Shoulder Arthroplasty Research Committee (ShARC), Arthrex, Inc., Naples, FL, USA
- 3Department of Orthopaedic Surgery, University of Virginia, Charlottesville, VA, USA
Abstract
Background: Augmented glenoid baseplates are increasingly used in reverse total shoulder arthroplasty (rTSA) to address glenoid deformity or preserve glenoid bone stock. The purpose of this study was to compare 2-year clinical and radiographic outcomes of standard and augmented baseplates with the Modular Glenoid System (Modular Glenoid System; Arthrex, Inc., Naples, FL, USA).
Methods: A retrospective matched cohort study was conducted using a prospectively maintained multi-center database of patients who underwent primary rTSA, with a mean follow-up of 23.3 months (18.1-32.1 months) in the augmented group and 23.5 months (18.4-31.5 months) in the standard group. A total of 209 augmented baseplates were identified and matched to 209 standard baseplates. Direct matching of the groups was performed using age, sex, and estimated total glenoid lateralization as pre-defined criteria. Clinical outcomes and range of motion findings were compared using the change from baseline to the final follow-up.
Results: The augmented cohort had a higher prevalence of glenoid deformity, including Walch B (40.2% vs. 19.6%; P < .001) and C (4.8% vs. 0.5%; P = .006) glenoids. The augmented group showed greater improvement in American Shoulder and Elbow Surgeons score (44.5 ± 21.4 vs. 38.9 ± 22.8, P = .010), although the difference did not exceed reported thresholds for clinical significance. No differences were observed in other patient-reported outcomes or range of motion. The incidence of radiolucent lines around the glenoid (P = .308) and screw breakage or implant migration (P = .123) were similar between groups. On the Firth penalized multivariable logistic regression analysis in the augmented cohort, complete glenoid seating >80% was associated with lower odds of radiolucent lines around the glenoid (odds ratio 0.21, 95% confidence interval 0.06-0.81; P = .025). Bicortical post fixation, augment size (10° vs. 20°), and lateralization category (≤4 mm vs. ≥6 mm) were not significantly associated with radiolucent lines.
Conclusion: At approximately 2 years following a primary rTSA with the Modular Glenoid System, matched cohorts receiving augmented and standard baseplates demonstrated similar improvements in most clinical outcomes and similar short-term radiographic fixation findings despite greater pre-operative glenoid deformity in the augmented cohort. The observed association between >80% baseplate seating and lower odds of radiolucent lines in the augmented group should be considered exploratory given the low number of radiographic events.
Related
- Rural and Urban Hospitals Demonstrate Different Patterns of Declining Inpatient Arthroplasty Volume, 2013-2023
- CPAK Phenotype Transitions After Mechanically Aligned Total Knee Arthroplasty: A Retrospective Cohort Study of Radiographic Patterns and 12-Month Patient-Reported Outcomes
- Radiographic view strongly influences detection of humeral component migration after stemless shoulder arthroplasty
- Image-based robotic-assisted patellofemoral arthroplasty for isolated patellofemoral osteoarthritis: Short-term survivorship, clinical and radiographic outcomes
- Comparison of Fluoroscopy Use Between Two Radiographic Overlay Techniques for Limb Length and Femoral Offset Assessment During Direct Anterior Approach Total Hip Arthroplasty
BibTeX
@article{rimkunas2026augmented,
title = {{Augmented and standard baseplates demonstrate similar clinical and radiographic outcomes following reverse shoulder arthroplasty with the Arthrex modular Glenoid System}},
author = {Augustinas Rimkunas and Monish Avvaru and Shoulder Arthroplasty Research Committee (ShARC) and Brian C. Werner and Patrick J. Denard},
journal = {JSES international},
year = {2026},
month = oct,
doi = {10.1016/j.jseint.2026.101813},
url = {https://europepmc.org/article/PMC/PMC13788712},
note = {CC BY-NC-ND},
}
RIS
TY - JOUR
TI - Augmented and standard baseplates demonstrate similar clinical and radiographic outcomes following reverse shoulder arthroplasty with the Arthrex modular Glenoid System
AU - Augustinas Rimkunas
AU - Monish Avvaru
AU - Shoulder Arthroplasty Research Committee (ShARC)
AU - Brian C. Werner
AU - Patrick J. Denard
PY - 2026
DA - 2026/10/21
JO - JSES international
DO - 10.1016/j.jseint.2026.101813
UR - https://europepmc.org/article/PMC/PMC13788712
AB - Background: Augmented glenoid baseplates are increasingly used in reverse total shoulder arthroplasty (rTSA) to address glenoid deformity or preserve glenoid bone stock. The purpose of this study was to compare 2-year clinical and radiographic outcomes of standard and augmented baseplates with the Modular Glenoid System (Modular Glenoid System; Arthrex, Inc., Naples, FL, USA). Methods: A retrospective matched cohort study was conducted using a prospectively maintained multi-center database of patients who underwent primary rTSA, with a mean follow-up of 23.3 months (18.1-32.1 months) in the augmented group and 23.5 months (18.4-31.5 months) in the standard group. A total of 209 augmented baseplates were identified and matched to 209 standard baseplates. Direct matching of the groups was performed using age, sex, and estimated total glenoid lateralization as pre-defined criteria. Clinical outcomes and range of motion findings were compared using the change from baseline to the final follow-up. Results: The augmented cohort had a higher prevalence of glenoid deformity, including Walch B (40.2% vs. 19.6%; P < .001) and C (4.8% vs. 0.5%; P = .006) glenoids. The augmented group showed greater improvement in American Shoulder and Elbow Surgeons score (44.5 ± 21.4 vs. 38.9 ± 22.8, P = .010), although the difference did not exceed reported thresholds for clinical significance. No differences were observed in other patient-reported outcomes or range of motion. The incidence of radiolucent lines around the glenoid (P = .308) and screw breakage or implant migration (P = .123) were similar between groups. On the Firth penalized multivariable logistic regression analysis in the augmented cohort, complete glenoid seating >80% was associated with lower odds of radiolucent lines around the glenoid (odds ratio 0.21, 95% confidence interval 0.06-0.81; P = .025). Bicortical post fixation, augment size (10° vs. 20°), and lateralization category (≤4 mm vs. ≥6 mm) were not significantly associated with radiolucent lines. Conclusion: At approximately 2 years following a primary rTSA with the Modular Glenoid System, matched cohorts receiving augmented and standard baseplates demonstrated similar improvements in most clinical outcomes and similar short-term radiographic fixation findings despite greater pre-operative glenoid deformity in the augmented cohort. The observed association between >80% baseplate seating and lower odds of radiolucent lines in the augmented group should be considered exploratory given the low number of radiographic events.