Incidental pulmonary embolism detection on routine contrast-enhanced computed tomography before and after deployment of a commercial artificial intelligence tool: a real-world evaluation
Abstract
Objectives: To assess the impact of deploying AI software for pulmonary embolism (PE) detection on reporting rates of incidental PE (iPE) on routine contrast‑enhanced CT.
Methods: Consecutive adult patients undergoing contrast-enhanced CT in a large tertiary care hospital were included. Two time periods were compared: September 1-December 31, 2022 (before the introduction of dedicated artificial intelligence (AI) tools for PE detection) and September 1-December 31, 2023 (following introduction of AI). Cases positive for PE were identified retrospectively. Data on baseline demographics, imaging variables, and immediate clinical management were gathered from the electronic health record.
Results: A total of 11 690 contrast-enhanced CT studies were analyzed, 10 411 of which were eligible non-computed tomography pulmonary angiography (non-CTPA) studies. iPE detection rate increased from 0.35% to 0.63% (P = .0389) following AI implementation. The segmental iPE detection rate increased significantly (0.08% vs 0.42%, P < .001). In the post‑AI period, the iPE algorithm did not analyze 21.3% of non‑CTPA studies. AI sensitivity for iPE detection was 65.6% among analyzed studies and 60.0% when all eligible examinations were included. AI sensitivity was 71.4%, 77.8%, and 56.2% for early arterial, late arterial, and venous phase scans, respectively.
Conclusions: The introduction of a dedicated AI tool for iPE detection significantly increased iPE detection, particularly segmental iPE. This occurred despite incomplete AI analysis of eligible scans and a modest AI algorithm sensitivity. The proportion of eligible examinations processed by AI and algorithm sensitivity varied by CT protocol and contrast phase, highlighting the importance of evaluating and monitoring AI tools under real-world clinical conditions following implementation.
Advances in knowledge: Deployment of a commercial PE AI detection system in routine practice was associated with a significant increase in reported iPE on non‑CTPA CT, predominantly at the segmental level. However, the AI analyzed only 78.7% of eligible non-CTPA examinations, highlighting incomplete examination coverage as an important real-world implementation limitation. AI coverage and performance also varied across CT protocols and contrast phases, underscoring the importance of protocol-specific evaluation following clinical deployment.
Related
- Deployment of a Multilingual, Embodied, Holographic Artificial Intelligence Concierge in Ambulatory Care: Early Implementation Lessons From the Artificial Intelligence Responsive Interactive Agent.
- From Algorithm Performance to Laboratory Deployment: A Critical Review of Artificial Intelligence in Clinical Chemistry
- Real-World Experience With Artificial Intelligence-Enabled Natural Language Processing for Identification and Management of Incidental Lung Nodules
- Clinical Validation, Bias, and Ethical Deployment of Artificial Intelligence in Imaging.
- Artificial Intelligence–Based Classification of Mandibular Condylar Position Using Cone-Beam Computed Tomography: A Single-Center Internal Evaluation
BibTeX
@article{oherlihy2026incidental,
title = {{Incidental pulmonary embolism detection on routine contrast-enhanced computed tomography before and after deployment of a commercial artificial intelligence tool: a real-world evaluation}},
author = {Fergus O’Herlihy and Dora Gorman and Lara Toerien and Fionnuala Ni Ainle and Brian Gibney and Peter MacMahon},
journal = {The British Journal of Radiology},
year = {2026},
month = sep,
doi = {10.1093/bjr/tqag222},
url = {https://doi.org/10.1093/bjr/tqag222},
note = {CC BY 4.0},
}
RIS
TY - JOUR
TI - Incidental pulmonary embolism detection on routine contrast-enhanced computed tomography before and after deployment of a commercial artificial intelligence tool: a real-world evaluation
AU - Fergus O’Herlihy
AU - Dora Gorman
AU - Lara Toerien
AU - Fionnuala Ni Ainle
AU - Brian Gibney
AU - Peter MacMahon
PY - 2026
DA - 2026/09/10
JO - The British Journal of Radiology
DO - 10.1093/bjr/tqag222
UR - https://doi.org/10.1093/bjr/tqag222
AB - Objectives: To assess the impact of deploying AI software for pulmonary embolism (PE) detection on reporting rates of incidental PE (iPE) on routine contrast‑enhanced CT. Methods: Consecutive adult patients undergoing contrast-enhanced CT in a large tertiary care hospital were included. Two time periods were compared: September 1-December 31, 2022 (before the introduction of dedicated artificial intelligence (AI) tools for PE detection) and September 1-December 31, 2023 (following introduction of AI). Cases positive for PE were identified retrospectively. Data on baseline demographics, imaging variables, and immediate clinical management were gathered from the electronic health record. Results: A total of 11 690 contrast-enhanced CT studies were analyzed, 10 411 of which were eligible non-computed tomography pulmonary angiography (non-CTPA) studies. iPE detection rate increased from 0.35% to 0.63% (P = .0389) following AI implementation. The segmental iPE detection rate increased significantly (0.08% vs 0.42%, P < .001). In the post‑AI period, the iPE algorithm did not analyze 21.3% of non‑CTPA studies. AI sensitivity for iPE detection was 65.6% among analyzed studies and 60.0% when all eligible examinations were included. AI sensitivity was 71.4%, 77.8%, and 56.2% for early arterial, late arterial, and venous phase scans, respectively. Conclusions: The introduction of a dedicated AI tool for iPE detection significantly increased iPE detection, particularly segmental iPE. This occurred despite incomplete AI analysis of eligible scans and a modest AI algorithm sensitivity. The proportion of eligible examinations processed by AI and algorithm sensitivity varied by CT protocol and contrast phase, highlighting the importance of evaluating and monitoring AI tools under real-world clinical conditions following implementation. Advances in knowledge: Deployment of a commercial PE AI detection system in routine practice was associated with a significant increase in reported iPE on non‑CTPA CT, predominantly at the segmental level. However, the AI analyzed only 78.7% of eligible non-CTPA examinations, highlighting incomplete examination coverage as an important real-world implementation limitation. AI coverage and performance also varied across CT protocols and contrast phases, underscoring the importance of protocol-specific evaluation following clinical deployment.
SN - 0007-1285
SN - 1748-880X
ER -