Skip to content
DraconiticResearch
Search Sources API
203,203 studies31 sourcesUpdated 49 min ago
Peer-reviewedCC BY 4.0Journal of Clinical Medicine

CT-Based Assessment of Femoral Stem Anteversion After Intentional Intraoperative Rotational Adjustment of a Single-Wedge Tapered Stem in Total Hip Arthroplasty

  1. 1Department of Orthopedic Surgery, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul 06229, Republic of Korea

Abstract

Background/Objectives: Prosthetic anteversion (PA) is generally considered to be constrained by three-point fixation in the sagittal plane. However, previous studies have reported inconsistent changes from native femoral anteversion (NFA) to prosthetic anteversion (PA), ranging from no appreciable change to a mean increase of approximately 8°, suggesting that PA may not be determined by femoral anatomy alone. This study aimed to evaluate whether femoral stem anteversion can be intentionally adjusted towards a target angle and to identify factors associated with failure to achieve the intended correction. Methods: We retrospectively reviewed 142 hips in 133 patients who underwent total hip arthroplasty with a target PA of 30°. Hips were divided into increased-anteversion (Group 1) and decreased-anteversion (Group 2) groups according to the intended correction relative to NFA. Correlations between targeted and actual correction angles and factors associated with correction failure were analyzed separately for each group. Results: Of 142 hips, 126 were classified as Group 1 and 16 as Group 2. PA significantly increased from NFA in Group 1 (12.72 ± 9.24° vs. 25.17 ± 7.13°; p < 0.001) but not in Group 2 (39.13 ± 6.73° vs. 37.84 ± 7.88°; p = 0.513). A lower CCR and intended decrease in anteversion were associated with correction failure. In Group 1, targeted and actual correction angles were significantly correlated (r = 0.633, p < 0.001). Conclusions: Femoral stem anteversion can be intentionally increased using a single-wedge tapered stem, particularly in femora with a high CCR. However, the feasibility of intentionally decreasing anteversion requires further investigation.

Related

  1. Intraoperative Transverse Acetabular Ligament-Guided Radiographic Anteversion: Concordance With Hip-Spine Targets and Combined Anteversion.
    Kyosuke Kobayashi, Kenichi Kidera, Syuta Yamada +2
    Arthroplasty todayPeer-reviewedCC BYFull textSurgery & anaesthesiaEurope PMC
  2. Intraoperative Assessment of Component Loosening in Hip Arthroplasty: An International Delphi Consensus
    Alon G.M. Hopman, Leendert Blankevoort, Derek Amanatullah +40
    The Journal of ArthroplastyPeer-reviewedCC BYFull textSurgery & anaesthesiaHAL
  3. Accuracy of intraoperative limb length control using the NaviFast 6D system in total hip arthroplasty
    Ireneusz Urbaniak, Tomasz Dekert, Jan Blacha +6
    Scientific ReportsPeer-reviewedCC BY-NC-ND 4.0Full textSurgery & anaesthesiaCrossref
  4. Agreement and Systematic Differences Between Intraoperative ROSA Hip-Knee-Ankle Measurements and Standing Radiographic Alignment After Robotic-Assisted Total Knee Arthroplasty: A Retrospective Agreement Study
    Wei-Cheng Tseng, Ching-Heng Lin, Yu-Tsung Lin +6
    Journal of clinical medicinePeer-reviewedCC BYFull textGeneral medicineEurope PMC
  5. Intraoperative Proximal Fibula Fracture during Total Knee Arthroplasty for Moderate Valgus Knee Deformity: A Case Report.
    Siddharth Khadilkar, Ronak J Mahatme, Shawn Moore +3
    Journal of orthopaedic case reportsPeer-reviewedCC BY-NCFull textSurgery & anaesthesiaEurope PMC
BibTeX
@article{yoon2026ctbased,
  title = {{CT-Based Assessment of Femoral Stem Anteversion After Intentional Intraoperative Rotational Adjustment of a Single-Wedge Tapered Stem in Total Hip Arthroplasty}},
  author = {Soon-Phil Yoon and Byung Woo Cho and Minjae So and Tae Hyeong Kim and Woo-Suk Lee},
  journal = {Journal of Clinical Medicine},
  year = {2026},
  month = oct,
  doi = {10.3390/jcm15197643},
  url = {https://www.mdpi.com/2077-0383/15/19/7643},
  note = {CC BY 4.0},
}
RIS
TY  - JOUR
TI  - CT-Based Assessment of Femoral Stem Anteversion After Intentional Intraoperative Rotational Adjustment of a Single-Wedge Tapered Stem in Total Hip Arthroplasty
AU  - Soon-Phil Yoon
AU  - Byung Woo Cho
AU  - Minjae So
AU  - Tae Hyeong Kim
AU  - Woo-Suk Lee
PY  - 2026
DA  - 2026/10/02
JO  - Journal of Clinical Medicine
DO  - 10.3390/jcm15197643
UR  - https://www.mdpi.com/2077-0383/15/19/7643
AB  - Background/Objectives: Prosthetic anteversion (PA) is generally considered to be constrained by three-point fixation in the sagittal plane. However, previous studies have reported inconsistent changes from native femoral anteversion (NFA) to prosthetic anteversion (PA), ranging from no appreciable change to a mean increase of approximately 8°, suggesting that PA may not be determined by femoral anatomy alone. This study aimed to evaluate whether femoral stem anteversion can be intentionally adjusted towards a target angle and to identify factors associated with failure to achieve the intended correction. Methods: We retrospectively reviewed 142 hips in 133 patients who underwent total hip arthroplasty with a target PA of 30°. Hips were divided into increased-anteversion (Group 1) and decreased-anteversion (Group 2) groups according to the intended correction relative to NFA. Correlations between targeted and actual correction angles and factors associated with correction failure were analyzed separately for each group. Results: Of 142 hips, 126 were classified as Group 1 and 16 as Group 2. PA significantly increased from NFA in Group 1 (12.72 ± 9.24° vs. 25.17 ± 7.13°; p < 0.001) but not in Group 2 (39.13 ± 6.73° vs. 37.84 ± 7.88°; p = 0.513). A lower CCR and intended decrease in anteversion were associated with correction failure. In Group 1, targeted and actual correction angles were significantly correlated (r = 0.633, p < 0.001). Conclusions: Femoral stem anteversion can be intentionally increased using a single-wedge tapered stem, particularly in femora with a high CCR. However, the feasibility of intentionally decreasing anteversion requires further investigation.
SN  - 2077-0383
ER  -