Cardiac MRI at 3.0T in the presence of implantable cardioverter defibrillators (ICDs)

  1. 1TUM University Hospital German Heart Center, Munich, Germany

Abstract

Patients with implantable cardioverter-defibrillators (ICDs) often are excluded from receiving CMR scans at 3.0T due to ICD-induced image artifacts. This work aims to transfer sequence protocols established for CMR imaging in the presence of ICDs at 1.5T to a first human application at 3.0T. All measurements were performed on a clinical 3T MRI scanner. Phantom measurements were used to establish and optimize wideband PSIR LGE imaging at 3.0T. Volunteer measurements with externally placed ICDs were used for optimization of CINE imaging and wideband PSIR imaging. Thirdly, patients with implanted ICD were examined with the optimized protocols. Human measurements showed that SA stacks obtained with spoiled GRE after contrast agent showed a markedly lower artifact burden than the conventional approach. For scar imaging, a wideband PSIR with a bandwidth of 3kHz and a frequency offset of +750Hz allowed a sufficient suppression of relevant artifacts in the majority of scans. No strong correlation between the image quality and the distance between the cardiac silhouette and the device was detected. The presented work shows the feasibility of clinical cardiac MRI at 3.0T including GRE-CINE and wideband PSIR-LGE for patients with ICDs.

Related

  1. Machine Learning-Based Prediction of Long-Term Mortality in Patients with Implantable Cardioverter Defibrillators
    Lei Pan, Zilong Xiao, Ziqing Yu +8
    Journal of cardiovascular development and diseasePeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
  2. Predictive Value of the Electrical Risk Score for Ventricular Arrhythmias in Heart Failure Patients with Primary Prevention Implantable Cardioverter Defibrillators
    Pelin Aladag, Ilke Erbay, Naile Eris Gudul +1
    Journal of clinical medicinePeer-reviewedCC BYFull textCardiovascular medicineEurope PMCCrossref
  3. Radiofrequency ablation with a conventional solid tip catheter in contact with an implantable cardioverter-defibrillator coil causing inadvertent ventricular fibrillation.
    Michael R Manogue
    HeartRhythm case reportsPeer-reviewedCC BY-NC-NDFull textCardiovascular medicineEurope PMC
  4. Ventricular fibrillation treated by an implantable cardioverter-defibrillator in antimitochondrial M2 antibody-positive myocarditis.
    Kanto Saida, Atsushi Sudo, Takunori Aoyama +2
    HeartRhythm case reportsPeer-reviewedCC BYFull textCardiovascular medicineEurope PMC
  5. Transient defibrillation threshold elevation associated with air in the generator pocket after extravascular implantable cardioverter-defibrillator implantation.
    Junji Morita, Kenichiro Yamagata, Yuhei Kasai +1
    HeartRhythm case reportsPeer-reviewedCC BY-NC-NDFull textCardiovascular medicineEurope PMC
BibTeX
@misc{reiter2026cardiac,
  title = {{Cardiac MRI at 3.0T in the presence of implantable cardioverter defibrillators (ICDs)}},
  author = {T. Reiter and O. M. Weber and i. Weiss and N. Kraus and S. Kress and W. R. Bauer},
  howpublished = {medRxiv},
  year = {2026},
  month = oct,
  doi = {10.64898/2026.10.16.26364740},
  url = {https://www.medrxiv.org/content/10.64898/2026.10.16.26364740v1},
  note = {CC BY-ND},
}
RIS
TY  - UNPB
TI  - Cardiac MRI at 3.0T in the presence of implantable cardioverter defibrillators (ICDs)
AU  - T. Reiter
AU  - O. M. Weber
AU  - i. Weiss
AU  - N. Kraus
AU  - S. Kress
AU  - W. R. Bauer
PY  - 2026
DA  - 2026/10/16
PB  - medRxiv
DO  - 10.64898/2026.10.16.26364740
UR  - https://www.medrxiv.org/content/10.64898/2026.10.16.26364740v1
AB  - Patients with implantable cardioverter-defibrillators (ICDs) often are excluded from receiving CMR scans at 3.0T due to ICD-induced image artifacts. This work aims to transfer sequence protocols established for CMR imaging in the presence of ICDs at 1.5T to a first human application at 3.0T. All measurements were performed on a clinical 3T MRI scanner. Phantom measurements were used to establish and optimize wideband PSIR LGE imaging at 3.0T. Volunteer measurements with externally placed ICDs were used for optimization of CINE imaging and wideband PSIR imaging. Thirdly, patients with implanted ICD were examined with the optimized protocols. Human measurements showed that SA stacks obtained with spoiled GRE after contrast agent showed a markedly lower artifact burden than the conventional approach. For scar imaging, a wideband PSIR with a bandwidth of 3kHz and a frequency offset of +750Hz allowed a sufficient suppression of relevant artifacts in the majority of scans. No strong correlation between the image quality and the distance between the cardiac silhouette and the device was detected. The presented work shows the feasibility of clinical cardiac MRI at 3.0T including GRE-CINE and wideband PSIR-LGE for patients with ICDs.
ER  -