Skip to content
DraconiticResearch
Search Sources API
197,768 studies31 sourcesUpdated 41 min ago
PreprintCC BY-SA 4.0arXiv

A High Precision Metacalibration Response Correction

Abstract

In Metacalibration the shear response of a weak lensing measurement is estimated by applying an artificial shear to the image, but the shear operation imprints a spin-2 modulation on the image noise power, which biases the measured response. The standard fix adds a sheared noise field that symmetrizes the anisotropy, at the cost of doubling the noise variance (√2 in the noise). The fusion correction presented in this note reaches the same unbiased response while adding only the minimum power needed. It measures the noise power transfer by passing an impulse through the Metacal process, forms the common-level azimuthal deficit that equalizes the spin-2 (m=2) and spin-6 (m=6) modulations across the metacal types, and adds just that deficit by filtering the rotated noise field. The fusion correction raises the per-pixel noise by only ∼2% for a round PSF (versus √2 for the standard correction), rising toward the √2 level only for highly elliptical PSFs.

Related

  1. Setup and performance of focal-plane characterization benches for high precision astrometry
    Fabrice Pancher, Sebastien Soler, Fabien Malbet +7
    arXivPreprintarXiv licenceFull textInstrumentation & methodsOptics & photonicsarXiv
  2. Calibrations for high precision differential astrometry onboard Theia and HWO
    Manon Lizzana, Fabien Malbet, Hugo Rousset +3
    arXivPreprintarXiv licenceFull textInstrumentation & methodsarXiv
  3. Simulation-based inference of profile evolution for high-precision pulsar timing
    Sai C. Susarla, Gregory Ashton, A. Parthasarathy +2
    arXivPreprintCC BY 4.0Full textHigh-energy astrophysicsInstrumentation & methodsarXiv
  4. Night-sky emission correction techniques for high-resolution spectroscopy: Demonstration with NIRPS
    Avidaan Srivastava, François Bouchy, Xavier Dumusque +54
    arXivPreprintCC BY 4.0Full textInstrumentation & methodsarXiv
  5. CAMB v2: cosmological power spectra for high-precision surveys
    Antony Lewis
    arXivPreprintCC BY 4.0Full textCosmologyarXiv
BibTeX
@misc{sheldon2026high,
  title = {{A High Precision Metacalibration Response Correction}},
  author = {Erin S. Sheldon},
  howpublished = {arXiv},
  year = {2026},
  month = oct,
  doi = {10.48550/arxiv.2610.35998},
  eprint = {2610.35998},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2610.35998},
  note = {CC BY-SA 4.0},
}
RIS
TY  - UNPB
TI  - A High Precision Metacalibration Response Correction
AU  - Erin S. Sheldon
PY  - 2026
DA  - 2026/10/26
PB  - arXiv
DO  - 10.48550/arxiv.2610.35998
UR  - https://arxiv.org/abs/2610.35998
AB  - In Metacalibration the shear response of a weak lensing measurement is estimated by applying an artificial shear to the image, but the shear operation imprints a spin-2 modulation on the image noise power, which biases the measured response. The standard fix adds a sheared noise field that symmetrizes the anisotropy, at the cost of doubling the noise variance (√2 in the noise). The fusion correction presented in this note reaches the same unbiased response while adding only the minimum power needed. It measures the noise power transfer by passing an impulse through the Metacal process, forms the common-level azimuthal deficit that equalizes the spin-2 (m=2) and spin-6 (m=6) modulations across the metacal types, and adds just that deficit by filtering the rotated noise field. The fusion correction raises the per-pixel noise by only ∼2% for a round PSF (versus √2 for the standard correction), rising toward the √2 level only for highly elliptical PSFs.
ER  -