Abstract
Background/objectives
Vaginal atresia, most commonly caused by Müllerian agenesis, is treated with vaginal dilation therapy or surgical vaginoplasty; however, dilation therapy requires prolonged patient adherence. In a previous study, a single, statically implanted vaginal expansion sleeve (VES) produced significant lengthening of vaginal tissue. This study evaluated whether progressive serial VES expansion increases vaginal canal length and whether the length gained is retained after device removal.Methods
Baseline vaginal canal length was measured in four intact (non-ovariectomized) Sprague-Dawley rats. A VES, a spring-like woven cylinder, was custom-fabricated at 1.3 times the vaginal canal length, implanted for one week, and then replaced with a larger device; this was repeated weekly for three weeks. After serial expansion, animals recovered for two weeks before final measurements. Changes in length over time were analyzed using repeated-measures ANOVA, and vaginal tissue was harvested for histologic analysis.Results
Mean vaginal canal length increased from 24.50 ± 0.58 mm at baseline to 37.25 ± 2.87 mm at Week 3, a 52% increase (n = 4; p < 0.0001 for change over time). Two weeks after VES removal, the mean length was 35.50 ± 0.58 mm, 11.0 mm above baseline, indicating retention of approximately 86% of the length gained. Histologic examination showed impaired squamous maturation or regenerative changes, mixed inflammation, muscularis disruption, and interspersed subepithelial fibrosis.Conclusions
Serial VES expansion produced significant vaginal lengthening that was largely maintained after device removal. The histologic findings indicate a tissue response to sustained mechanical expansion, the long-term significance of which remains unknown. Serial VES-mediated distraction vaginogenesis warrants further study.
Related
- Large prolapsed ureterocele with tissue necrosis presenting as vaginal bleeding and urinary retention in an adult woman: a case report
- Universal cervical length screening and vaginal progesterone: Distinguishing strategy effectiveness from treatment efficacy
- Beyond Mechanical Exclusion: Immune and Cellular Remodeling After Stent-Graft Implantation in Type B Aortic Dissection
- Gut microbiome-derived metabolic remodeling and the butyrate-IL-18 inflammatory axis after transcatheter aortic valve implantation
- Biventricular Reverse Remodeling After Percutaneous Pulmonary Valve Implantation With a Self-Expandable Pulsta Valve in Native Right Ventricular Outflow Tract
BibTeX
@article{colvin2026remodeling,
title = {{Remodeling and Retention of Vaginal Canal Length via Sleeve Implantation: A Preclinical Study.}},
author = {Joshua C Colvin and Hannah R Meyer and Collyn C O'Quin and Donald L Sorrells and Rusella Mirza and Valerie L Welch and Gracie Gotberg and Giovanni F Solitro and Jonathan S Alexander and Mila D Shah-Bruce},
journal = {Pathophysiology : the official journal of the International Society for Pathophysiology},
year = {2026},
month = oct,
doi = {10.3390/pathophysiology33040082},
url = {https://europepmc.org/article/MED/43081287},
note = {CC BY},
}
RIS
TY - JOUR
TI - Remodeling and Retention of Vaginal Canal Length via Sleeve Implantation: A Preclinical Study.
AU - Joshua C Colvin
AU - Hannah R Meyer
AU - Collyn C O'Quin
AU - Donald L Sorrells
AU - Rusella Mirza
AU - Valerie L Welch
AU - Gracie Gotberg
AU - Giovanni F Solitro
AU - Jonathan S Alexander
AU - Mila D Shah-Bruce
PY - 2026
DA - 2026/10/31
JO - Pathophysiology : the official journal of the International Society for Pathophysiology
DO - 10.3390/pathophysiology33040082
UR - https://europepmc.org/article/MED/43081287
AB - Background/objectives Vaginal atresia, most commonly caused by Müllerian agenesis, is treated with vaginal dilation therapy or surgical vaginoplasty; however, dilation therapy requires prolonged patient adherence. In a previous study, a single, statically implanted vaginal expansion sleeve (VES) produced significant lengthening of vaginal tissue. This study evaluated whether progressive serial VES expansion increases vaginal canal length and whether the length gained is retained after device removal.Methods Baseline vaginal canal length was measured in four intact (non-ovariectomized) Sprague-Dawley rats. A VES, a spring-like woven cylinder, was custom-fabricated at 1.3 times the vaginal canal length, implanted for one week, and then replaced with a larger device; this was repeated weekly for three weeks. After serial expansion, animals recovered for two weeks before final measurements. Changes in length over time were analyzed using repeated-measures ANOVA, and vaginal tissue was harvested for histologic analysis.Results Mean vaginal canal length increased from 24.50 ± 0.58 mm at baseline to 37.25 ± 2.87 mm at Week 3, a 52% increase (n = 4; p < 0.0001 for change over time). Two weeks after VES removal, the mean length was 35.50 ± 0.58 mm, 11.0 mm above baseline, indicating retention of approximately 86% of the length gained. Histologic examination showed impaired squamous maturation or regenerative changes, mixed inflammation, muscularis disruption, and interspersed subepithelial fibrosis.Conclusions Serial VES expansion produced significant vaginal lengthening that was largely maintained after device removal. The histologic findings indicate a tissue response to sustained mechanical expansion, the long-term significance of which remains unknown. Serial VES-mediated distraction vaginogenesis warrants further study.
SN - 0928-4680
SN - 1873-149X
ER -