Skip to content
DraconiticResearch
Search Sources API
201,683 studies31 sourcesUpdated 25 min ago
PreprintarXiv licencearXiv

Microkelvin resolution thermometry at the nanometre scale

Abstract

Accurate temperature readings of transient events at the nanometer scale are challenging due to the low sensitivity of available sensors. Nanodiamonds containing nitrogen-vacancy (NV) centers have been used for nanoscale thermometry in complex environments, including inside living cells. However, their performance has been limited by short coherence times and low photon counts. In this work, we use isotopically-purified dual-NV nanodiamonds and a bespoke quantum sensing chip to showcase an order of magnitude improvement in temperature measurement sensitivity compared with previous reports. We demonstrate robust temperature measurements with an error of 682 μK, experimental sensitivities below 50 mK/surd Hz and a shot-noise limited sensitivity of 9.6 mK/surd Hz. To confirm the utility of these high-performance nanothermometers, we quantify the temperature change induced by the thermometry measurement itself, specifically the optical excitation laser used to probe the NV spin state. In addition, we observe directly at the nanometre scale the transient heating caused by the exothermic mixing of dimethyl sulfoxide in water. Sub-millikelvin resolution and millikelvin sensitivity thermometry unlock the possibility of monitoring minute thermal fluctuations in living systems and assessing catalyst performance at the nanometre scale.

Related

  1. Sub-microkelvin resolution temperature sensing using orthogonal polarization modes in a fiber ring resonator
    Ze-Long Huang, Jie Xu, Jue Li +5
    Optics ExpressPeer-reviewedPublisher termsOptics & photonicsCrossref
  2. Tip-enhanced molecular fluorescence microscopy with atomic-scale resolution
    Anna Rosławska, Katharina Kaiser, Sofia Canola +5
    Reviews of Modern PhysicsPeer-reviewedCC BY-NC-ND 4.0Full text2 citedGeneral physicsHAL
  3. Everything at Every Scale: Scale-Invariant Diffusion with Continuous Super-Resolution
    Zixin Jessie Chen, Zhuo Chen, Archer Wang +4
    arXivPreprintarXiv licenceFull textStatistical & nonlinear physicsarXiv
  4. Picometre-scale real-time drift correction in TEM and STEM by dynamic control of the specimen stage for atomic-resolution imaging
    Christophe Gatel, Julien Dupuy, Teresa Hungria +1
    UltramicroscopyPeer-reviewedCC BY 4.0Full textApplied physics & instrumentationCondensed matterHALarXiv
  5. Extreme-Scale Super-Resolution of Homogeneous Turbulence from a Single Realization
    Arth Sojitra, Muhammad Abid, Omer San
    arXivPreprintarXiv licenceFull textFluid dynamicsarXiv
BibTeX
@misc{hart2026microkelvin,
  title = {{Microkelvin resolution thermometry at the nanometre scale}},
  author = {Jack W. Hart and Soham Pal and Julien R. E. Roth and Katie Ninham and Abbie H. Aleksandrova and Xander Peetroons and Soumen Mandal and Oliver A. Williams and Gavin W. Morley and Mete Atature and Helena S. Knowles},
  howpublished = {arXiv},
  year = {2026},
  month = sep,
  doi = {10.48550/arxiv.2609.04907},
  eprint = {2609.04907},
  archivePrefix = {arXiv},
  url = {https://arxiv.org/abs/2609.04907},
}
RIS
TY  - UNPB
TI  - Microkelvin resolution thermometry at the nanometre scale
AU  - Jack W. Hart
AU  - Soham Pal
AU  - Julien R. E. Roth
AU  - Katie Ninham
AU  - Abbie H. Aleksandrova
AU  - Xander Peetroons
AU  - Soumen Mandal
AU  - Oliver A. Williams
AU  - Gavin W. Morley
AU  - Mete Atature
AU  - Helena S. Knowles
PY  - 2026
DA  - 2026/09/04
PB  - arXiv
DO  - 10.48550/arxiv.2609.04907
UR  - https://arxiv.org/abs/2609.04907
AB  - Accurate temperature readings of transient events at the nanometer scale are challenging due to the low sensitivity of available sensors. Nanodiamonds containing nitrogen-vacancy (NV) centers have been used for nanoscale thermometry in complex environments, including inside living cells. However, their performance has been limited by short coherence times and low photon counts. In this work, we use isotopically-purified dual-NV nanodiamonds and a bespoke quantum sensing chip to showcase an order of magnitude improvement in temperature measurement sensitivity compared with previous reports. We demonstrate robust temperature measurements with an error of 682 μK, experimental sensitivities below 50 mK/surd Hz and a shot-noise limited sensitivity of 9.6 mK/surd Hz. To confirm the utility of these high-performance nanothermometers, we quantify the temperature change induced by the thermometry measurement itself, specifically the optical excitation laser used to probe the NV spin state. In addition, we observe directly at the nanometre scale the transient heating caused by the exothermic mixing of dimethyl sulfoxide in water. Sub-millikelvin resolution and millikelvin sensitivity thermometry unlock the possibility of monitoring minute thermal fluctuations in living systems and assessing catalyst performance at the nanometre scale.
ER  -