Hypertrophic cardiomyopathy phenotype is associated with postmyectomy change in diastolic function measured by artificial intelligence-enabled electrocardiogram.
- 1Department of Cardiovascular Surgery, Mayo Clinic, Rochester, Minn.
- 2Department of Cardiovascular Medicine, Mayo Clinic, Rochester, Minn.
Abstract
Objectives
Diastolic dysfunction may persist after septal myectomy for obstructive hypertrophic cardiomyopathy, contributing to residual or recurrent symptoms. To better understand postoperative diastolic function, we assessed the association between preoperative obstructive hypertrophic cardiomyopathy phenotypic characteristics and change in artificial intelligence-enabled electrocardiogram determined diastolic function, previously shown to quantify diastolic function.Methods
We analyzed 166 consecutive patients with obstructive hypertrophic cardiomyopathy undergoing septal myectomy with prospective artificial intelligence-enabled electrocardiogram diastolic function data. Participants were classified as improved diastolic function (improved grade or persistently normal filling pressure) or persistent diastolic dysfunction (worsened grade or persistently high filling pressure).Results
The study population was 41% female with a median age of 59 years. There was no significant difference in baseline clinical characteristics between patients with improved diastolic function or persistent artificial intelligence-enabled electrocardiogram diastolic dysfunction. Patients with worsened postoperative diastolic dysfunction by artificial intelligence-enabled electrocardiogram had a greater left atrial volume index (P < .01), a greater left ventricular mass index (P < .01), a higher medial E/e' ratio (P < .01), and increased posterior wall thickness (P < .01) compared with those with improved or normal filling pressure grades by artificial intelligence-enabled electrocardiogram. All-cause mortality was low with no significant difference between artificial intelligence-enabled electrocardiogram diastolic function groups (adjusted hazard ratio, 0.84; 95% CI, 0.14-2.06).Conclusions
Change in artificial intelligence-enabled electrocardiogram diastolic function is associated with echocardiographic predictors of diastolic dysfunction in obstructive hypertrophic cardiomyopathy patients undergoing septal myectomy. Patients with an advanced obstructive hypertrophic cardiomyopathy phenotype preoperatively may be less likely to experience improvement in diastolic function after septal myectomy based on artificial intelligence-enabled electrocardiogram diastolic grade changes.
Related
- Artificial Intelligence-Enhanced Cardiac Magnetic Resonance in Hypertrophic Cardiomyopathy: Diagnosis, Phenotypic Characterization, and Risk Prediction
- Artificial Intelligence-Enhanced Electrocardiography for Detection and Prediction of Hypertrophic Cardiomyopathy across Monogenic and Polygenic Susceptibility
- Mavacamten improves energy balance in a pre-clinical model of RASopathy-associated hypertrophic cardiomyopathy
- A late bloom at the apex: development of apical hypertrophic cardiomyopathy phenotype in advanced age
- Research trends and hotspot analysis of sudden cardiac death in hypertrophic cardiomyopathy : A bibliometric analysis
BibTeX
@article{debertin2026hypertrophic,
title = {{Hypertrophic cardiomyopathy phenotype is associated with postmyectomy change in diastolic function measured by artificial intelligence-enabled electrocardiogram.}},
author = {Julia G Debertin and Hartzell V Schaff and Masoomeh Aslahishahri and Joseph A Dearani and Steve R Ommen and Paul A Friedman and Zachi I Attia and Tedy Sawma and Konstantinos C Siontis and Eunjung Lee and Jae K Oh and Jeffrey B Geske},
journal = {JTCVS open},
year = {2026},
month = jul,
doi = {10.1016/j.xjon.2026.101947},
url = {https://europepmc.org/article/MED/42948102},
note = {CC BY-NC-ND},
}
RIS
TY - JOUR
TI - Hypertrophic cardiomyopathy phenotype is associated with postmyectomy change in diastolic function measured by artificial intelligence-enabled electrocardiogram.
AU - Julia G Debertin
AU - Hartzell V Schaff
AU - Masoomeh Aslahishahri
AU - Joseph A Dearani
AU - Steve R Ommen
AU - Paul A Friedman
AU - Zachi I Attia
AU - Tedy Sawma
AU - Konstantinos C Siontis
AU - Eunjung Lee
AU - Jae K Oh
AU - Jeffrey B Geske
PY - 2026
DA - 2026/07/02
JO - JTCVS open
DO - 10.1016/j.xjon.2026.101947
UR - https://europepmc.org/article/MED/42948102
AB - Objectives Diastolic dysfunction may persist after septal myectomy for obstructive hypertrophic cardiomyopathy, contributing to residual or recurrent symptoms. To better understand postoperative diastolic function, we assessed the association between preoperative obstructive hypertrophic cardiomyopathy phenotypic characteristics and change in artificial intelligence-enabled electrocardiogram determined diastolic function, previously shown to quantify diastolic function.Methods We analyzed 166 consecutive patients with obstructive hypertrophic cardiomyopathy undergoing septal myectomy with prospective artificial intelligence-enabled electrocardiogram diastolic function data. Participants were classified as improved diastolic function (improved grade or persistently normal filling pressure) or persistent diastolic dysfunction (worsened grade or persistently high filling pressure).Results The study population was 41% female with a median age of 59 years. There was no significant difference in baseline clinical characteristics between patients with improved diastolic function or persistent artificial intelligence-enabled electrocardiogram diastolic dysfunction. Patients with worsened postoperative diastolic dysfunction by artificial intelligence-enabled electrocardiogram had a greater left atrial volume index (P < .01), a greater left ventricular mass index (P < .01), a higher medial E/e' ratio (P < .01), and increased posterior wall thickness (P < .01) compared with those with improved or normal filling pressure grades by artificial intelligence-enabled electrocardiogram. All-cause mortality was low with no significant difference between artificial intelligence-enabled electrocardiogram diastolic function groups (adjusted hazard ratio, 0.84; 95% CI, 0.14-2.06).Conclusions Change in artificial intelligence-enabled electrocardiogram diastolic function is associated with echocardiographic predictors of diastolic dysfunction in obstructive hypertrophic cardiomyopathy patients undergoing septal myectomy. Patients with an advanced obstructive hypertrophic cardiomyopathy phenotype preoperatively may be less likely to experience improvement in diastolic function after septal myectomy based on artificial intelligence-enabled electrocardiogram diastolic grade changes.
SN - 2666-2736
ER -